ADA INSTRUMENTS COSMO 40 User Manual [ru]

Operating manual
Laser distance meter
Model: COSMO 40
Manufacturer: ADAINSTRUMENTS Address: WWW.ADAINSTRUMENTS.COM
COSMO 40
2
Table of contents
1. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Menu functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4. Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5. Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6. Message codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Techical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8. Measuring conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9. Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
10. Warranty/ Exceptions from responsibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Appendix 1 - “Certificate of acceptance and sale” Appendix 2 - “Warranty card”
COSMO 40
Congratulations on the purchase of laser distance meter ADA COSMO 40!
Permitted use
· Measuring distances
· Computing functions, e.g. areas, volumes, subtractions, Pythagorean calculation
· Storing measurements
The safety regulations and instructions along with the operating manual should be read carefully before initial operation.The person responsible for the instrument must ensure that equipment is used in accor­dance with the instructions. This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use.
3
COSMO 40
4
SAFETY INSTRUCTION
Prohibited use
Please follow up instructions given in operating manual. Do not use instrument in explosive environment (filling station, gas equipment, chemical production and so on). Do not remove warning labels or safety instructions. Do not open instrument housing, do not change it’s construction or modification. Do not stare at beam. Laser beam can lead to eye injury (even from greater distances). Do not aim laser beam at persons or animals. Opening of the equipment by using tools (screwdrivers, etc.), as far as not specifically permitted for certain cases. Inadequate safety precautions at the surveying site (e.g. when measuring on the roads, construction sites and so on). Use the instrument in the places where it could be dangerous: on the air transport, near manufacturers, production facilities, in the places where the work of laser distance meter can lead to the harmful effects on people or animals.
Laser classification
The instrument is a laser class 2 laser product with power < 1 mW and wavelength 635 nm. Laser is safety in ordinary conditions of usage.
START UP
Keypad
1) ON / Measure
2) Area / Volume / Pythagorean measure
3) Reference
4) Clear / OFF
5) Addition / Subtraction/ Units
COSMO 40
5
1
5
2
3
4
COSMO 40
6
9
8
1
2
7
6
3
5
Display
1) Laser ON
2) Reference (front/rear)
3) Area / volume/ Pythagorean
4) Main line
5) Line 2
6) Line 1
7) Units
8) Battery level
9) Error
4
COSMO 40
Inserting / Replacing Batteries
Remove the end piece on 180º. Remove the battery cover, insert the battery correctly. Pay attention to correct polarity. Close the battery compartment. Replace the battery when symbol constantly blinks in the display. Batteries should be removed in case of danger of corrosion, if the device will not be used for a long time.
MENU FUNCTIONS
Swtich on and off
Press the button (1) to switch on the instrument and laser. Press and hold key for about 2 seconds to start continuous measuring. The device also switches off automatically after 3 minutes of inactivity i.e. no key is pressed within that interval. To switch off the instrument press and hold button (4) for about 2 sec.
7
COSMO 40
8
Reference Setting
Default reference setting is from the rear of the device. Press the button (3) to set the reference: the front or the rear. When the end-piece is folded out fully, the reference rear is set. You will see the reference symbol on the display.
Selecting Units
Press and hold the button (5) for 2 sec. until the desired unit is displayed.
Clear-Key
Cancel the last action. Press button (4).
MEASUREMENTS
Single distance measurement
Press button (1) to activate the laser. When in continuous laser mode, press this button to trigger the distance measurement directly. The instrument will give acoustical signal. The result is displayed immediately.
COSMO 40
Continuous Measurement
Press and hold the button (1) for about 2 seconds to start continuous measuring.
Minimum/ Maximum measurement
This function allows the user to measure the minimum or maximum distance from a fixed measuring point. It is commonly used to measure room diagonals (maximum values) or horizontal distances (minimum values). Press and hold down the button (1), until you will hear acoustical signal. Then slowly sweep the laser back and forth and up and down over the desired target point (e.g. into the corner of a room). Press (1) to stop continuous measurement. The values for maximum and minimum distances are shown on the display as well as the last measured value in the main line.
FUNCTIONS
Distance measuring
Press button (5): next measurement is added to the previous one. Press button (5): next measurement is substracted from the previous one.
9
COSMO 40
10
To complete this function press button (1). Repeat this function to measure distances. The result is desplayed in the main display area. Previous measured value is displayed in the first line, last measured value is dis­played in the second line. To finish working in this mode press button (4).
Area
Press the button (2) once.The symbol “area” is displayed. Press button (1) to take the first measurement (for example, length). Measured value is displayed in the second line. Press button (1) to take the second measurement (for example, width). Measured value is displayed in the second line. First measurement (e.g. length) is displayed in the first line. The result of measured area is displayed in the main display area.
Addition / Subtraction of areas
Area measuring – see Area. Take the first measurement of area. Press button (5) to enter into the Addition mode or button (5) once more to enter into the Subtraction mode. Area value is displayed in the second line.
COSMO 40
Press button (1) to take the first measurement (for example, length). Press button (1) to take the second measurement (for example, width). After the completion of area, press button (1) , the result of addition/substraction of areas is displayed in the main display area. If the measurements are not finished, press button (5) (addition) or (5) (substraction) to continue calculations.
Volume
For volume measurements, press button (2) twice until the indicator for volume measurement appears on the display. Press button (1) to take the first measurement (for example, length). Measured value is displayed in the second line. Press button (1) to take the second measurement (for example, width). Measured value is displayed in the second line. Area value is displayed in the first line. Press button (1) to take the third measurement (for example, height). Measured value is displayed in the second line.
11
COSMO 40
12
The volume value will be displayed in the main display area and the previous area value is displayed in the first line.
Indirect measurement
Pythagorean measurement is used in the condition that the objective needing to be measured is covered or has no effective reflecting surface and can’t be measured directly.
Make sure you adhere to the prescribed sequence of measurement: All target points must be in a horizontal or vertical plane. The best results are achieved when the instrument is rotated about a fixed point (e.g. with the positioning bracket fully folded out and the instrument placed on a wall) or the instrument is mounted on a tripod. The minimum / maximum function can be used. The minimum value must be used for measurements at right angles to the target; the maximum distance for all other measurements. The best results are achieved when the instrument is rotated about a fixed point (e.g. with the positioning bracket fully folded out and the instrument placed on a wall) or the instrument is mounted on a tripod.
COSMO 40
Continious measurements can be used. This function is used for minimum/maximum measurements. The minimum value must be used for measurements at right angles to the target; the maximum distance for all other measurements. Be sure that the first measurement and distance are measured at right angles. Use continious measurement function.
Indirect measurement – determing a distance using 2 auxilary measurements
This function is used when height and distance can’t be measured directly.
Press button (2) 3 times. The symbol “triangle” is displayed. The distance to be measured is blinking in the symbol triangle. Press button (1) to take distance measuring (hypothenuse of triangle). The result is displayed in the second line. This measurement can be taken in the indirect measurement function. Press and hold but­ton (1) for 2 sec. After second pressure of the button (1) maximum value is fixed. The second distance to be measured is blinking in the symbol triangle. Press button (1) to take distance measuring. There is a right angle between laser beam and the length you need to measure. That’s why you should work in continious mode. Press and hold button (1) for 2 sec. After second pressure of the button (1)
13
COSMO 40
14
maximum distance is fixed. The result of the measurement is displayed in the second line. Previous measure­ment is displayed in the first line. The result of the function is displayed in the main display area.
Indirect measurement – determing a distance using 3 measurements
This function is used when it’s necessary to measure diagonals of rectangular areas, and also for calculation of the length of frameworks, inclined distances and so on.
Press button (2) 4 times. The symbol “triangle” is displayed. The distance to be measured is blinking in the symbol triangle. Press button (1) to take distance measuring (side of the triangle) . The result of the function is displayed in the second line. This measurement can be taken in the mode of continious measurement. Press and hold button (1) for 2 sec. After second pression of the button (1) maximum value is fixed. The second distance to be measured is blinking in the symbol triangle. It’s very important to have right angle between laser beam and the length you need to measure. That’s why you should work in continious mode. Press and hold button (1) for 2 sec. After second pressure of the button (1) maximum distance is fixed. The result of the function is displayed in the main display area. Previous measurement is displayed in the first line.
COSMO 40
MESSAGE CODES
All message codes are displayed with either “Info” or symbol “telephone receiver” (Error). Following mistakes can be corrected.
INFO CAUSE REMEDY
204
Calculation overflow Repeat procedure
205
Out of measuring range Choose measuring distance within measuring range
252
Temperature too high Cool down instrument
253
Temperature too low Warm up instrument
255
Receiver signal too weak Use target plate
15
COSMO 40
16
256
257
258
Received signal too strong Use target plate (grey side)
Wrong measurement Use target plate (brown side)
Wrong initialization Switch on – off the instrument
Hardware error Switch on/off the device several times and check if
the symbol still appears. If so please call your dealer for assistance.
TECHNICAL DATA
Range, without target, m 0.05 to 40
Accuracy, mm ±1.5*
Smallest unit displayed 1 mm
Laser class 2
Laser type 635 nm, <1 mW
IP rating IP 54
Automatic switch off 3 minutes of inactivity
Battery life, 2 x AAA > 5000 measurements
COSMO 40
17
COSMO 40
18
Dimensions, mm 114×50×25
Weight 120 g
Temperature range: Storage Operating
* In favourable conditions (good target surface properties, room temperature). Maximum deviation occurs under unfavorable conditions such as bright sunlight or when measuring to poorly reflecting or very rough surfaces.
-25º to +70º
-10º to +50º