Acuson Sequoia Ultrasound System User manual

Sequoia® Ultrasound System Service Training Manual
Service Training Department Acuson Corporation 1220 Charleston Road Mountain View, CA 94039 (650) 969-9112 (800) 4-ACUSON
Manual Assy P/N 58323, Rev. 1 Language: English CE
Acuson Confidential
ii Sequoia Service Training Manual P/N 59191 Rev. 1
COPYRIGHT Copyright © 2000 by Acuson Corporation. All rights reserved.
No part of this publication may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Acuson Corporation.
Acuson Corporation reserves the right to change its products and services at any time. In addition, this manual is subject to change without notice. Acuson Corporation welcomes customer input on corrections and suggestions for improvements to this manual.
Although Acuson Corporation has attempted to ensure accuracy throughout this manual, Acuson Corporation assumes no liability for any errors or omissions, nor for any damages resulting from the application or use of this information.
TRADEMARKS Acuson, AEGIS, CasePro, DELTA, MultiHertz, RES, Sequoia,
SpaceTime, The Value of Vision, Vector, 128XP, and XP are registered trademarks of Acuson Corporation. Aspen, Cadence, Convergent, DIMAQ, DTI, EF, FreeStyle, microCase, Multizone, Native, NewView, Perspective, ProtoCALL, QuantX, Quik-Clip, Solo, SST, and WebPro are trademarks of Acuson Corporation.
Cidex, Cidex Plus, and Cidex 7 are registered trademarks of Surgikos, Inc. K-Y Lubricating Gel is a trademark of Johnson & Johnson Products, Inc. IBM is a registered trademark of International Business Machines Corporation. Metricide is a trademark of Metrex Research Corporation. Omnicide is a trademark of Cottrell, Ltd. Panasonic is a trademark of Matsushita Electric Industrial Co. Ltd. Polaroid is a registered trademark of Polaroid Corporation. 3M is a registered trademark of Minnesota Mining and Manufacturing. Apple, AppleTalk, EtherTalk, LocalTalk, Macintosh, MultiFinder, and LaserWriter are trademarks of Apple Computer, Inc. DOT is a registered trademark of Digital Optical Technologies. Pinnacle Micro Inc., Kodak, and Ektascan are registered trademarks of Eastman Kodak Company. PostScript is a registered trademark of Adobe Systems, Incorporated. Ricoh is a trademark of Ricoh Company, Ltd. Sony is a registered trademark of Sony Corporation of America. Verbatim is a registered trademark of Ve r ba t i m C o rp o r at i on . Tos o h i s a t ra d e ma r k o f To s oh Corporation. Multi-Imager is a trademark of International Imaging Electronics.
All other product names are trademarks of their respective companies.
CAUTION! The Food and Drug Administration of the United States Government
restricts use of this device to or on the order of a physician.
P/N 59191 Rev. 1 Sequoia Service Training Manual iii
Acuson Confidential
LICENSE A
GREEMENT
All computer programs copyright 1990-2001 by Acuson Corporation OR ITS SUPPLIERS. Such programs are licensed under the following software license agreement:
Acuson or its suppliers retain(s) ownership of and title to any computer program supplied with the equipment and to the trade secrets embodied in such computer programs. Subject to the Buyer’s acceptance and fulfillment of the obligations in this paragraph, Acuson grants the Buyer a personal, non­transferable, perpetual, non-exclusive license to use any computer program supplied with the Equipment that is necessary to operate the Equipment solely on the medium in which such program is delivered for the purpose of operating the equipment in accordance with the instructions set forth in the operator’s manuals supplied with the Equipment and for no other purpose whatsoever. Buyer may not reverse-assemble, reverse-compile or otherwise reverse-engineer such computer programs nor may Buyer make a copy of such program or apply any techniques to derive the trade secrets embodied therein. In the event of a failure by Buyer to comply with the terms of this license, the license granted by this paragraph shall terminate. Further, because unauthorized use of such computer programs will leave Acuson without an adequate remedy at law, Buyer agrees that injunctive or other equitable relief will be appropriate to restrain such use, threatened or actual. Buyer further agrees that (i) any of Acuson's suppliers of software is a direct and intended beneficiary of this end-user sublicense and may enforce it directly against Buyer with respect to software supplied by such supplier, and (ii) NO SUPPLIER OF ACUSON SHALL BE LIABLE TO BUYER FOR ANY GENERAL, SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL, INCIDENTAL OR OTHER DAMAGES ARISING OUT OF THE SUBLICENSE OF THE COMPUTER PROGRAMS SUPPLIED WITH THE EQUIPMENT.
REVISION HISTORY
QRC P/N-REVISION INITIATOR APPROVAL DATE CHANGE
S. WilliamsJuly 1999Incorporate reviewer comments
A3210 P/N 59191 Rev. 1 J. Madarasz S. Williams Dec. 2000 Initial Release.
Acuson Confidential
iv Sequoia Service Training Manual P/N 59191 Rev. 1
CONTENTS
MODULE 1 Introducing Sequoia® Ultrasound Technology
Sequoia Ultrasound Technology 1-3
Coherent Imageformer 1-4
DIMAQ Integrated Ultrasound Workstation 1-5
Doppler Technologies 1-6
Transducer Technology 1-7
Worksheet: System Technology 1-8
MODULE 2 Basic Ultrasound Physics
Introducing Ultrasound 2-3
Ultrasound Applications 2-4
Ultrasound Imaging 2-5
Transducers 2-6
Ultrasound Beam Focusing 2-11
Ultrasound Wave Reception 2-13
2-D Artifacts and Enhancements 2-15
2-D Image Acquisition 2-19
Scan Conversion 2-20
Components of Image Quality 2-22
Other 2-D Features 2-25
Doppler Principles 2-26
Spectral Doppler 2-27
Understanding Blood Flow 2-30
Artifacts of Spectral Doppler 2-31
Color Doppler 2-32
Color Doppler Modes 2-34
M-Mode 2-35
Ultrasound Module Questions 2-37
P/N 59191 Rev. 1 Sequoia Service Training Manual v
Acuson Confidential Contents
MODULE 3 Scanning
Module Overview 3-3
Beginning A Scanning Session 3-5
Carotid Artery 2-D Imaging 3-7
Spectral Doppler Imaging 3-9
Color Doppler Imaging 3-12
Liver & Kidney Imaging 3-15
Cardiology/Heart Imaging 3-17
Image Enhancements 3-22
Data Field Values 3-28
Scanning a Phantom 3-30
Scanning Reference Information 3-31
Using AEGIS® 3-32
Scanning Questions 3-34
128XP® User Interface 3-35
Aspen 1.0 to 4.0 System User Interface 3-36
Aspen and Sequoia Systems New User Interface 3-37
MODULE 4 Field Replaceable Units (FRUs)
Overview 4-3
Accessing and Removing FRUs 4-4
Brief Board Descriptions 4-8
System Monitor Assembly 4-11
User Interface FRUs 4-13
Covers and Card Cage Assembly 4-19
AUX and FIZ Modules 4-26
Power Subsystem 4-28
SCSI Devices 4-32
Worksheet: FRU Removal and Re-install 4-34
Acuson Confidential
vi Sequoia Service Training Manual P/N 59191 Rev. 1
MODULE 5 System Architecture
Overview 5-4
System Architecture 5-5
Coherent Imageformer 5-7
Theory of Operation 5-8
Transmitter Board 5-11
Multiplexer Board 5-12
Receiver Board 5-13
Beamformer Board 5-15
Controller Board 5-16
DIMAQ Integrated Ultrasound Workstation 5-17
Color and Spectral Doppler Board 5-22
BDM Board 5-23
Reconstruction and Display Processor Board 5-24
Input/Output Video Board 5-25
Input/ Output Expansion Board 5-26
Peripheral Interface Controller Board 5-27
Physio Interface Module 5-28
Front Panel Processor Board 5-29
2-D/ M-Mode Signal Flow 5-30
Solo Spectral Doppler Signal Flow 5-33
Color Doppler Signal Flow 5-35
ECG/Physio Signal Flow 5-37
DIMAQ System Store and Review 5-38
VCR Playback 5-40
Worksheet: System Architecture 5-41
MODULE 6 Power Distribution
Overview 6-3
Power Supply Architecture 6-4
Theory of Operation 6-6
Power Subassemblies 6-10
Accessory Isolated Power 6-14
System Cabling Diagram 6-15
Minimum Configuration Requirements 6-16
Power Usage 6-17
Worksheet: Power Supplies 6-18
P/N 59191 Rev. 1 Sequoia Service Training Manual vii
Acuson Confidential Contents
MODULE 7 Configuring the Sequoia System
Overview 7-3
Customizing System Set-up 7-4
System Configuration 7-13
Board Configuration 7-14
Worksheet: Configuration 7-15
MODULE 8 Diagnostic Tools
Overview 8-3
Learning MSM Tools 8-4
Expert System Tools 8-10
Viewing Sequoia System Logs 8-13
Worksheet: MSM Tools 8-17
MODULE 9 Installing Peripherals
Questions 9-3
MODULE 10 Sequoia Troubleshooting Tools
Overview 10-3
Recommended Approach 10-4
Identifying Symptoms 10-5
Stage 1 - System Down 10-6
Stage 2 - No Boot 10-8
Stage 3 - Functionality Problem 10-10
Stage 4 - Subtle Image Quality Problems 10-11
Stage 5 - Lock-ups 10-12
Stage 6 - Intermittent 10-12
Choosing Appropriate Tools for the Symptom 10-13
Managing Sequoia System Logs 10-16
Worksheet: Fault Isolation 10-20
Troubleshooting Scenarios 10-21
Acuson Confidential
viii Sequoia Service Training Manual P/N 59191 Rev. 1
MODULE 11 Verifying the Sequoia System
Overview 11-3
Mechanical Inspection 11-4
Electrical Verification 11-5
Preparing for Performance Verification 11-6
Hardware Verification 11-8
Functional Verification 11-9
AEGIS System Functional Verification 11-15
Peripheral Device Verification 11-16
Worksheet: Verification 11-17
MODULE 12 Installing the Sequoia System
Overview 12-3
Worksheet: Installation 12-4
MODULE 13 Upgrading the Sequoia System
Overview 13-3
Worksheet: Upgrades 13-4
MODULE 14 Advanced Diagnostic Tools
Overview 14-3
Connecting the Laptop Hardware 14-4
Setting Hyper Terminal 14-5
Setting Reflection Options 14-6
Using the Sequoia Terminal 14-8
Running Diagnostics 14-11
Saving Data 14-12
Worksheet: Field Laptop 14-13
MODULE 15 Acusons Service Programs
P/N 59191 Rev. 1 Sequoia Service Training Manual ix
Acuson Confidential Contents
MODULE 16 Stress Echo Cardiography
Overview 16-3
Defining Stress Echo Cardiography 16-4
Exercise Stress Program 16-5
Pharmacological Stress Program 16-6
How Does It Work? 16-8
Connecting the ECG from OEMs 16-13
Typical Stress Echo Problems and Solutions 16-16
Worksheet: Stress Echo 16-18
MODULE 17 Interpreting Boot Sequence
Overview 17-3
Sequoia Boot Sequence 17-4
Sequoia 3.nn Boot Details 17-6
Boot Messages 17-7
Boot Sequence Example 17-10
Worksheet: Boot Sequence 17-14
Acuson Confidential
x Sequoia Service Training Manual P/N 59191 Rev. 1
PREFACE
Acuson is pleased to welcome you to the Sequoia® ultrasound systems. The Sequoia systems are special-purpose machines designed for general radiology, obstetrics, gynecology, cardiology, and/or vascular exams.
Acuson systems have an exceptional record of dependability, and Acuson has a customer service network ready to respond to the needs of our customers.
For information on Acusons service offerings, please consult the Acuson Service Provider or call us at 800-9-ACUSON or 650-969-
9112. For local numbers outside the United States, see the Contacting Acuson heading in this section.
ABOUT THIS MANUAL
The purpose of this manual is to familiarize service personnel with basic operation, maintenance, and troubleshooting of Sequoia systems. Service personnel are expected to be familiar with the use of basic test equipment (DVM, oscilloscope, etc.) and with basic ultrasound theory.
Use this manual when servicing a Sequoia ultrasound system.
KEY CONVENTIONS This manual uses several conventions to refer to controls on the
system. The following list shows the conventions and their descriptions.
WARNING!
This manual is intended for use by trained service personnel. There are lethal voltages inside Sequoia systems. Bodily harm, possibly death, and damage to the system may result from untrained individuals opening the system.
Symbol Description
[LEFT]
Represents a soft key
CALC
Represents a key, knob, switch, or toggle control
CODE + SIZE
Means Press the CODE key and press SIZE
Indicates steps to follow to perform a procedure
NOTE: A Note indicates especially important information. It is not an alert to a
dangerous situation.
CAUTION! A Caution alerts the user to the potential for damage to the ultrasound
system or other equipment.
P/N 59191 Rev. 1 Sequoia Service Training Manual xi
Acuson Confidential Preface
Acuson provides special alphanumeric keys in several languages; however, in this manual, labels for all keys and annotation terms are given in English. To convert the system to another language, contact the Acuson Customer Service representative. For English and international keyboard layouts, see the Keyboard section of the User
Manual.
OTHER SEQUOIA SYSTEM MANUALS
In addition to this manual, the following manuals are available for the Sequoia system:
Acuson Sequoia
® Ultrasound System User Manual
The User Manual provides information used regularly to perform ultrasound exams. It explains how to operate the standard and optional features of the Sequoia system for radiology, obstetrics, cardiology, gynecology, and/or vascular exams, including the use of special purpose transducers such as endocavity transducers, transesophageal transducers, and interoperative transducers. It explains how to use transducer needle guides to perform biopsies. It also contains setup information, which is used less frequently. The User Manual addresses the reader who is familiar with ultrasound techniques; therefore, it does not include sonography training or clinical procedures.
Acuson Sequoia® Ultrasound System Reference Manual
The Reference Manual consists of the Safety Manual, the Tr a ns d u ce r Specifications Manual, and the Administrator Manual.
The Safety Manual explains system and transducer safety precautions and maintenance procedures.
The Tr an s du c er S pe c if ic at io ns M an u a l lists technical information about the individual transducers, including power value tables for all Acuson transducers.
The Administrator Manual describes system and calculation package setup options. In addition, it contains information on setting up and operating peripheral devices with the Sequoia system.
WARNING!
A Warning alerts the user to a potential risk of death or serious injury to the user or patient.
Acuson Confidential
xii Sequoia Service Training Manual P/N 59191 Rev. 1
CONTACTING ACUSON
For additional information about the Acuson system, contact the nearest Acuson office.
U.S.A.
Acuson Corporation, U.S.A. Telephone: 1-(650) 969-9112 1-800-4-ACUSON Fax: 1-(650) 964-8331
GREAT BRITAIN
Acuson Ltd., England Telephone: (44) 1895-251010 Fax: (44) 1895-202999
JAPAN
Acuson Nippon, K.K. Telephone: (81) 3-3316-3999 Fax: (81) 3-3316-7002
ASIA PACIFIC/LATIN AMERICA
Acuson Asia Pacific/Latin America, U.S.A.
Telephone: 1-(650) 969-9112 1-800-4-ACUSON Fax: 1-(650) 965-9471
FINLAND
Acuson OY Telephone: (358) 9-27092290 Fax: (358) 9-27092299
LATIN AMERICA
Acuson Latin America, U.S.A. Telephone: 1-(305) 596-3148 Fax: 1-(305) 596-3149
AUSTRALIA
Acuson Pty. Ltd. Telephone: (61) 29201-7777 Fax: (61) 29869-1600
FRANCE
Acuson S.A.R.L. Telephone: (33) 1-6929-8110 Fax: (33) 1-6446-9840
NORWAY
Acuson AS Telephone: (47) 67-58-02-00 Fax: (47) 67-58-15-30
BELGIUM
Acuson SA/NV Telephone: (32) 761-06-96 Fax: (32) 761-06-90
GERMANY
Acuson GmbH Telephone: (49) 91-31-82650 Fax: (49) 91-31-826565
RUSSIA
Acuson Intl Sales Corp. Moscow, Russia Telephone: (7) 095-956-0018
or (7) 095-956-0019 Fax: (7) 502-222-1269
CANADA
Acuson Canada Ltd. Telephone: 1-(416) 296-1634 Fax: 1-(416) 296-1259
HONG KONG
Acuson Hong Kong Ltd. Telephone: (852) 2574-7989 Fax: (852) 2574-6945
SINGAPORE
Acuson Singapore Pte Ltd. Telephone: (65) 254-8982 Fax: (65) 254-8952
DENMARK
Acuson AS Telephone: (45) 39179991 Fax: (45) 40300796
ITALY
Acuson S.p.A. Telephone: (39)02 982-591 Fax: (39)02 982-41107
SWEDEN
Acuson AB Telephone: (46) 8-594-40660 Fax: (46) 8-594-40675
EUROPE
Acuson EHQ. Telephone: (44) 1895-202960 Fax: (44) 1895-202965
SPAIN
Acuson Iberica S.A. Telephone: (34) 91-372-17-55 Fax: (34) 91-372-14-78
P/N 59191 Rev. 1 Sequoia Service Training Manual xiii
Acuson Confidential Course Procedures
COURSE PROCEDURES
COURSE ATTENDANCE
This class runs Monday through Thursday, from 8:00 A.M. to 5:30 P. M . i n t h e B u i l d i n g H Tr a i n i n g R o o m , w i t h a b r e a k f o r l u n c h a t about 11:30 A.M. In addition, students may stay after class or contact the instructor for additional help as needed.
There will be breaks between the sessions; however, please be sure to return to the training room on schedule.
MODULES Each module includes lab instructions, reference material, and
evaluation questions. When the module is complete, confer with the instructor to determine whether the objectives have been met before going on to the next module.
RESOURCES All references for the course are in the course modules and
handouts. Lab equipment is at each lab station. Please do not remove supplemental resources from the room. For copies, contact an instructor.
Please feel free to ask questions at any time. There will be Post-It notes by the back door. For an issue or question that cannot be resolved immediately, make a note of it on a Post-It note and stick it on the back door.
PRACTICE Feel free to use any classroom equipment to practice the module
skills. Ask for help or clarification as needed.
Acuson Confidential
xiv Sequoia Service Training Manual P/N 59191 Rev. 1
COURSE SCHEDULE
The schedule is approximate and may vary. Short breaks will be taken between sections as appropriate. One hour will be given for lunch some time between 11:30 A.M. and 1:30 P.M.
MONDAY
TUESDAY
WEDNESDAY
THURSDAY
TIME TOPIC
8:30 A.M. Course introduction & Acuson history
9:30 A.M. Introduction to Ultrasound Physics
11:00 A.M. Scanning lecture and lab: carotid artery
2:00 P.M. General imaging demo and lab
3:00 P.M. Cardiology demo and lab
4:00 P.M. Image Enhancements and AEGIS
8:00 A.M. Replacing field replaceable units (FRUs)
10:30 A.M. Scanner architecture lecture
1:00 P.M. Verifying the Scanner lab
2:15 P.M. System troubleshooting lab - Scanner
8:00 A.M. System architecture- DIMAQ workstation
9:30 A.M. Diagnostics lecture and lab
11:00 A.M. Software architecture lecture
1:15 P.M. Factory tour
2:00 P.M. System troubleshooting- DIMAQ workstation
8:00 A.M. Configuration lecture and lab
9:20 A.M. Power supply lecture and lab
11:00 A.M. Troubleshooting lecture
11:30 A.M. Acuson luncheon
1:00 P.M. Power supply and whole system troubleshooting
4:00 P.M. Verification lecture and lab
5:00 Course conclusion: certificates and evaluations
Loading...