AcuRite 01512 Instruction Manual

Instruction Manual
Professional Weather Center
model 01512
CONTENTS
Unpacking Instructions ........... 2
Package Contents .................. 2
Product Registration ............... 2
Features & Benets: 5-in-1....... 3
Features & Benets: Display.... 4
Back of Display...................... 6
Setup .................................... 7
5-in-1 Sensor Setup ................ 7
Display Setup ........................ 8
Set the Time, Date & Units ...... 9
Backlight Settings ................... 9
Placement Guidelines ............10
Questions? Contact Customer Support at
5-in-1 Sensor Installation........11
Using the Weather Center .....12
Rainfall Tracking ...................13
Weather Ticker .....................14
Troubleshooting ....................15
Care & Maintenance............. 17
Calibration ...........................17
Specications........................19
FCC Information ...................19
Customer Support ................ 20
Warranty............................. 20
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety
and retain it for future reference.
Unpacking Instructions
Remove the protective lm that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
Package Contents
1. Display with tabletop stand
2. 5-in-1 sensor
3. Sensor mounting bracket
4. Mounting hardware
5. Power adapter
6. Instruction Manual
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
Archive~ Products
Register a Product
2
Features & Benets
7
1
2
9
11
6
5-in-1 SENSOR
1. Rainfall Collector Funnel
2. Solar Cell Panel
Converts sunlight into power to run internal aspirating fan.
Internal Aspirating Fan
(not shown)
Draws ambient air into sensor to reduce solar radiation heating, resulting in more accurate
temperature measurement.
3. A-B-C Switch
ID code that must match display’s A-B-C switch to ensure units synchronize.
4. Battery Compartment
4
3
5
8
10
5. Temperature & Humidity Sensors
(internal)
6. Mounting Point
7. Wind Speed Anemometer
8. Wind Direction Vane
9. Mounting Bracket
10. Mounting Hardware
includes anchors & screws.
Qty Diameter Length
5 #4 3/4” 1 #4 1/2” 1 #6 1/2”
11. Debris Filter
Pre-installed to prevent debris from
entering the rain gauge.
3
Features & Benets
Display Unit
31
30 29
28 27
26 25
24
23
1 2 3 1 4
ARNING
cC':',---
,, 1, 1, II 1, II I &
'""'
5 6
7 8
9 10 11
12 13 14
15 16
22
21 20 19 18 17
4
1. Previous 2 Wind Directions
2. Current Wind Speed
3. Current Wind Direction
4. Current Indoor Temperature
Arrow icon indicates direction
temperature is trending.
5. Display Low Battery Indicator
6. Peak Wind Speed
Highest speed from the last 60
minutes.
7. Current Indoor Humidity
Arrow icon indicates direction humidity is trending.
8. Wind Speed Alert Indicator
Activates when wind speed is over
50 mph.
9. Clock
10. Rainfall Alert Indicator
Indicates rainfall of more than 1” (25 mm) of rain in 2 hours or less.
11. AUTO DIM Indicator
Indicates display is in auto-dimming
brightness mode (see page 9).
12. Current Rainfall Total
Accumulates data during rainfall.
13. 12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from your 5-in-1 sensor to generate your personal forecast.
14. Storm Alert Indicator
Activates when barometric
pressure drops.
15. Month/Year/All-Time Rainfall
16. Current Barometric Pressure
Arrow icon indicates direction
pressure is trending.
17. RAINFALL Button
Press to change the RAINFALL data being displayed (Month, Year, All-Time).
A
18. TButton
for setup preferences.
19. SET Button
for setup preferences.
20. V Button
for setup preferences.
21. SELECT Button
Press to change the WEATHER SELECT category data being displayed.
22. Weather Ticker
23. Heat Index/ Wind Chill Alert Indicator
Activates when heat index rises
over 90ºF (32ºC) or when wind
chill drops below -17ºF (-27ºC).
24. Learning Mode Icon
Disappears after weather forecast self-calibration is complete.
25. WEATHER SELECT
Displays heat index, dew point, wind chill, feels like, days with rain this month, and days since last recorded rainfall.
26. Date
27. Current Outdoor Humidity
Arrow icon indicates direction humidity is trending.
28. Average Wind Speed
of all speeds from past 2 minutes.
29. 5-in-1 Sensor Signal Strength
30. Sensor Low Battery Indicator
31. Current Outdoor Temperature
Arrow icon indicates direction
temperature is trending.
TM
5
Back of Display Unit
1
2
3
6
5
4
BACK OF DISPLAY UNIT
1. Integrated Hang Hole
For easy wall mounting.
2. Backlight Button
Dimmer control while using power adapter. Activates momentary backlight while on battery power.
3. Plug-in for Power Adapter
4. Removable Tabletop Stand
5. CLEAR ALL / RESET Button
Press to clear record currently being
viewed. Press AND HOLD for more than 10 seconds for full reset to factory defaults.
6. A-B-C Switch
ID code that must match 5-in-1 sensor’s A-B-C switch to ensure units synchronize.
7. Power adapter
8. Battery Compartment Cover
(not shown)
6
7
SETUP
5-in-1 Sensor Setup
Set the A-B-C Switch
1
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.
Install or Replace Batteries
2
Batteries MUST be installed for this product to operate. AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not
recommended.
The 5-in-1 sensor requires lithium batteries in low temperature conditions. Cold temperatures can
cause alkaline batteries to function improperly. Use lithium batteries in
the 5-in-1 sensor for temperatures
below -4ºF / -20ºC.
1. Slide off the battery
compartment cover.
2. Insert 4 x AA batteries into the
battery compartment, as shown. Follow the polarity (+/-) diagram in the battery
compartment.
3. Replace the battery cover.
3
Remove Rain Gauge Stabilizer
Locate and remove the rain gauge stabilizer (plastic tab) taped into
the bottom of the sensor. The rain
gauge will not function until this is
removed.
A-B-C Switch
1
Set to match
display unit
2
A B C
Install Batteries
4 AA Batteries
Rain Gauge Stabilizer
3
7
Remove and discard
Display Unit Setup
AcuRite recommends high quality alkaline batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.
Set the A-B-C Switch
1
The A-B-C switch is located inside
the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.
1
A B C
Plug Power Adapter into
2
Electrical Outlet
Install or Replace Batteries
3
(optional)
Insert 6 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery
compartment.
Install Backup
3
Batteries
6 AA Batteries (optional)
Plug in Power
2
Adapter
IMPORTANT: Batteries are a backup power source to preserve records in the event of
a power outage. Power adapter is the recommended primary power source to enjoy the full functionality of this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be
8
Loading...
+ 16 hidden pages