Activeforever Electronic Stethoscope Adult Black User Manual

Table of Contents
Three-Year Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
A Proper Fit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electronic Control Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Using Your Stethoscope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Powering Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Changing Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Changing Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Auto Shut Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
Powering Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Memory Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Replacing the Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Replacing the Diaphragm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ID Name Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Care, Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Thank you for purchasing a MABIS Signature Electronic Stethoscope.Please carefully read the operating and cleaning instructions to ensure that your new stethoscope will provide years of durability and reliable performance.
Three-Year Limited Warranty
This MABIS Stethoscope is guaranteed to be free from manufacturing defects for a period of three years from the date of purchase under normal use. MABIS Healthcare determines th at t he unit failed t o operate due to a manufacturing defect, the unit will be repaired or replaced at the option of MABIS Healthcare. Repair or replacement of the unit is the s ole remedy under this limited warranty. This warranty gives you specific legal rights, which vary from state to state. As a condition of this warranty, the enclosed warranty registration card must be completed and sent to us within 10 days of the purchase date.
This Limited Warranty constitutes MABIS Healthcare’s only responsibility and obligation to repair and/or replace materials or components.We mak e no other express or implied warranties, arising by operation of law or otherwise, or any warranty of merchantability or fitness for a particular use or purpose whether or not the use or pur pose has been disclosed to MABIS Healthcare in speci­fications, drawings or otherwise, and whether or not MABIS Healthcare’s prod­ucts are specifically designed and/or manufactured by MABIS Healthcare for the buyer’s use or purposes, except for the limited warranty stated above. MABIS will not be responsible for any indirect, incidental, special, consequen­tial, or punitive damages or other loss, including, but not limited to, damage to or loss of other property or equipment and personal injuries, whether to pur­chaser or others. MABIS shall in no event be liable to the purchaser for any amount in excess of the cost of repair and/or replacement of the unit.
Your MABIS Signature Electronic Stethoscope offers state-of-the-art technol­ogy with volume amplification and sound filtering systems. Sounds that are typically difficult to identify in standard stethoscopes can easily be heard.
Your Electronic Stethoscope is equipped with a built-in computer chip.Through this chip, aphonic and resonance effects are eliminated. Audio frequency is divided into three modes: Standard Bell, Diaphragm and Extended Diaphragm. Additionally, the electronic amplifying system adjusts for eight dif­ferent volumes.
The illustration below identifies the key parts to your Electronic Stethoscope.
Binaurals
Chestpiece
Diaphragm
Binaural Slider Button
Binaural Slider Sleeve
Tubing
Electronic
Control
Center
Mode Selection
Volume Control
21
Your Electronic Stethoscope is designed with an adjustable Binaural Slider Sleeve for controlling the angle of the binaural. Press the Binaural Slider Button and slide the sleeve up or down for comfort and proper position.
A Proper Fit
The binaurals on your Electronic Stethoscope are anatomically designed for superior acoustics, reliability and comfort.
When inserting into the ear canals, make sure that the ear tips are fac­ing forward.In addition, the binaur­al end caps are embossed with “L” (left) and “R”(right) to ensure prop­er positioning.
Electronic Control Center
Your Electronic Stethoscope features an independent Electronic Control Center, which is separate from the auscultation head. This diminishes operating noise caused by button manipulation, creating a more precise method of sound collection.
Using Your Stethoscope
Your Electronic Stethoscope is set with the following factory-set default settings:
At any time you can return to the default settings by pressing “-”and “+”simul­taneously for approximately three (3) seconds.The Orange, Green and Yellow lights will each flash once indicating the change.
Mode Bell Volume Level 4 Memory Function ON Auto-Shut Off ON
SETTING
3 4
Using Y our Stethoscope
POWERING UP
To turn the Electronic Stethoscope on:
1. Press the “+” button located at the bottom of the Control Center.
2.The green and orange lights will flash three (3) times.
3.The Mode and Volume level will be set at the setting previously used prior to the Electronic Stethoscope being turned off.
CHANGING MODES
Frequency Modes are identified by the following lights:
Yellow Extended Range
Orange Bell
Green Diaphragm
To change Modes:
1. Press the “M” button to select the next frequency mode.
2. Modes will change sequence as follows:
Yellow Õ Green Õ Orange Õ Yellow
CHANGING VOLUME
Eight (8) volume levels can be selected in each Mode. Press the “+” button to raise volume level. Press the “-” button to lower the volume level.
1. While in the Bell (Orange) Mode, the orange light will flash once to indicate a change in the volume level.
2. While in the Diaphragm (Green) Mode, the green light will flash once to indicate a change in the volume level.
3. While in the Extended (Yellow) Mode, the yellow light will flash once to indicate a change in the volume level.
4. Adjust the volume to minimum (1) or maximum (8) by sound.
FUNCTION BUTTON PRESS BUTTON VOLUME LEVELS FLASHES
ADJUST
VOLUME
“+” or “-” ONCE 1-8
MODE LIGHT
FLASHES
ONCE
FUNCTION BUTTON
MODE change “M” Once
PRESS
BUTTON
AUTO SHUT OFF
DISPLAY FLASHES
Yellow Õ Green Õ Orange Õ Yellow
5 6
Mode light
changes in
sequence
To extend the battery life, your Electronic Stethoscope comes with an auto-off function that will automatically turn the unit off after approximately 100 sec­onds after the last keyed operation.
To deactivate this feature, press the “-” and “M” button simultaneously for approximately three (3) seconds.The Yellow and Orange lights will flash three (3) times to indicate that the auto-off feature has been disabled.
AUTO SHUT OFF (continued)
The Electronic Stethoscope can be powered off by pressing the “M”button for approximately three (3) seconds;however, it is recommended that you enable the auto-off function prior to storing.To reactivate this feature, press the “-”and “M” buttons simultaneously for approximately three (3) seconds. The Yellow and Orange lights will flash twice to indicate that the auto-off feature has been reactivated.
FUNCTION BUTTON
Deactivate Auto
Shut Off
“-” and “M”
PRESS
BUTTON
Approximately
3 seconds
YELLOW LIGHT
(EXTENDED
MODE)
W W
ORANGE
LIGHT
(BELL MODE)
GREEN LIGHT
(DIAPHRAGM
MODE)
Flashes 3 times consecutively
MEMORY FEATURE
Your Electronic Stethoscope will automatically start in the most recently used sound mode and volume level when it is turned on.
To deactivate this feature, press the “+” and “M” buttons simultaneously for approximately three (3) seconds.The Yellow and Green lights will flash three (3) times to indicate that the memory feature has been disabled. Your stethoscope will return to the factory default settings when you restart it.
SETTING
Mode Bell Volume Level 4 Memory Function ON Auto-Shut Off ON
Reactivate Auto
Shut Off
“-” and “M”
Approximately
3 seconds
W W
Flashes 2 times consecutively
POWER OFF
Press the “M” button for approximately 3 seconds to turn the stethoscope off.
FUNCTION BUTTON
Power Off “M”
PRESS
BUTTON
Approximately
3 seconds
YELLOW LIGHT
(EXTENDED
MODE
ORANGE LIGHT
(BELL MODE)
W W W
7
GREEN LIGHT
(DIAPHRAGM
MODE)
To restore the auto memory feature, press the “+” and “M” buttons simultaneously for over three (3) seconds. The Yellow and Green lights will flash two (2) times.
FUNCTION BUTTON
Deactivate
Memory
Reactivate
Memory
“+” and “M”
“+” and “M”
PRESS
BUTTON
Approximately
3 seconds
Approximately
3 seconds
YELLOW LIGHT
(EXTENDED
MODE)
W W
W W
8
ORANGE
LIGHT
(BELL MODE)
GREEN LIGHT
(DIAPHRAGM
MODE)
Flashes 3 times consecutively
Flashes 2 times consecutively
Replacing the Batteries
The batteries need to be replaced when the Yellow and Orange lights remain illuminated when the Electronic Stethoscope is turned on. Replace the batter­ies with three (3) LR44 batteries or equivalent.
To replace the batteries in your Electronic Stethoscope:
1. Slide the battery cover away from the chestpiece.
2. Remove the three (3) batteries and properly dispose.
3. Insert three (3) new batteries with the positive (+) side facing up.
4. Carefully slide the battery cap into place.
NOTE: We recommend that you remove the batteries if the Electronic Stethoscope will not be used for an extended period of time.
FUNCTION
Low
battery
YELLOW LIGHT
(EXTENDED
MODE)
W W
ORANGE LIGHT
(BELL MODE)
GREEN LIGHT
(DIAPHRAGM
MODE)
FLASHES
3 times
Replacing the Diaphragm
Under normal conditions, it is not necessary to remove the rim and diaphragm for cleaning since the diaphragm can easily be cleaned with an isopropyl alco­hol wipe. If, however, it is necessary to remove the rim and diaphragm, care­fully follow these instructions:
Rim and Diaphragm Removal:
1. Using the palm of your hand, gently press down on the rim.
2. Twist the rim counterclockwise to remove both the rim and the diaphragm
(See diagram below).
Cleaning the Rim and Diaphragm:
1. Remove the diaphragm from the ring. The diaphragm can be cleaned with mild soapy water or isopropyl alcohol.
2. Carefully wipe down the chestpiece with isopropyl alcohol, making sure not to saturate the chestpiece. Excess moisture will damage the electrical components inside the chestpiece and void your warranty.
Rim and Diaphragm Reassembly:
1. Once the rim and diaphragm are completely dry, place the diaphragm into the inside of the rim.
2. Position the rim and diaphragm onto the chestpiece.Twist the rim clockwise to reattach it to the chestpiece.
9 10
Replacing the Eartips
An extra pair of eartips are provided with your Electronic Stethoscope. To replace eartips, unscrew the tips and replace with the alterna­tive pair.
ID Name Tag
Your Electronic Stethoscope features a spe­cially designed ID tag on the backside of the Control Box. This offers the opportunity to personalize your Electronic Stethoscope.
Care, Cleaning and Maintenance
Note: Failure to follow these recommendations may result in reliability prob-
lems, cause damage to the internal components of your Electronic Stethoscope and void your warranty. Internal damage may cause malfunc­tion ranging from a slight decrease in auditory response to complete failure of the Electronic Stethoscope.
• To extend the life of your Electronic Stethoscope, avoid extreme changes
in temperature, solvents and oils.
• Ear tips, binaurals, plastic tubing, control box and chestpiece can be
cleaned with a soft cloth and isopropyl alcohol.
• Do not immerse your Stethoscope into any liquid or use high thermal
sterilization processes.
• Ear tips should be removed for a more thorough cleaning.
• Use only LR44 batteries or equivalent.
• Do not disassemble or attempt to repair the Electronic Stethoscope.
• Recommended storage temperature conditions are -4°F - 140°F
(-20°C - 60°C) and 15% to 95% relative humidity.
• Recommended usage temperature conditions are -5°F - 60°F
(-21°C - 16°C) and 20% to 95% relative humidity.
11 12
Troubleshooting
Specifications
CONDITION POSSIBLE
CAUSE
Will not switch on.
Will not change modes. Batteries are weak.
Device is ON, but cannot hear sounds.
High background noise
It is difficult to hear sounds.
Dead batteries or improperly installed batteries.
The volume may be set too low.
The volume setting may be too high.
Volume is set too low. The stethoscope is set in the wrong Mode.
13 14
CORRECTIVE
ACTION
Check batteries. Replace all three (3) batteries if necessary.
Replace all three (3) batteries.
Increase the volume using the “+” button.
Reduce the volume using the “-” button.
Use the “+” button to increase the volume. Use the “M” button to change the Mode.
Name MABIS®Signature Electronic Stethoscope, and Model 10-400-020 Sound Amplifier 3 dB ±2% of each volume level Storage Temperature -4°F - 140°F (-20°C - 60°C) and
15% to 95% relative humidity
Usage Temperature 23°F - 140°F (-5°C - 60°C) and
20% to 95% relative humidity
Latex-Free This product does not contain any latex ingredients Eartips Two pairs of screw-on plastic eartips are included Dimensions 22”Y-tubing Batteries (3) LR44 or equivalent
The MABIS Signature Electronic Stethoscope meets the norms: EN IEC 60601-01, EN EC 60601-1-2 (EMC), and EN IEC 60601-1-4
Production certified ISO9002/EN460002.ISO13488 The MABIS Signature Electronic Stethoscope is a medical appliance of class
CL 1 and complies with the relevant norms of the guideline MDD93/42/EEC.
Specifications subject to change without notice.
#91-032-400 08/07
©2007 MABIS Healthcare