ActiveAire 48262 User Manual

SAFETY DATA SHEET
1. Identification
GP PRO ActiveAire® Urinal Screen, LavenderProduct identifier
Product list
Other means of identification
Recommended use
Recommended restrictions
Manufacturer/Importer/Supplier/Distributor information
Company name Address
Telephone
E-mail
Emergency phone number
2. Hazard(s) identification
Emergency overview
Physical hazards
Health hazards
Environmental hazards
OSHA defined hazards
GP PRO ActiveAire® Low-Splash Deodorizer Urinal Screen, Lavender SKU 48262 GP PRO ActiveAire® Deodorizer Urinal Screen, Lavender SKU 48272
None.
Take precautionary measures against static discharge.
Georgia-Pacific Consumer Products LP 133 Peachtree Street, NE Atlanta, GA 30303 Technical Information 866.435.5647 (M)SDS Request 404.652.5119 MSDSREQ@GAPAC.com
Chemtrec - Emergency 800.424.9300
This is a consumer care product that is safe for consumers when used according to the label directions.
Not classified.
long-term hazard
Not classified.
Category 1Sensitization, skin
Category 3Hazardous to the aquatic environment,
Label elements
Signal word
Hazard statement
Precautionary statement
Prevention
Response
Storage
Disposal
Hazard(s) not otherwise classified (HNOC)
Supplemental information
Warning
May cause an allergic skin reaction. Harmful to aquatic life with long lasting effects.
In case of prolonged or frequently repeated contact, wear protective gloves. Do not eat, drink or smoke when using this product. Avoid release to the environment.
If on skin: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/attention. Wash contaminated clothing before reuse. Specific treatment (see section 4 on the SDS).
Store away from strong oxidizing agents.
Dispose of contents/container in accordance with local/regional/national/international regulations.
None known.
None.
3. Composition/information on ingredients
Mixtures
CAS number %Common name and synonymsChemical name
FRAGRANCE*
Other components below reportable levels 70 - 80
Proprietary*
20 - 30
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
SDS US
1 / 7
Composition comments
4. First-aid measures
Inhalation
Skin contact
Eye contact
Ingestion
Most important symptoms/effects, acute and delayed
Indication of immediate medical attention and special treatment needed
General information
5. Fire-fighting measures
Suitable extinguishing media
Unsuitable extinguishing media
Specific hazards arising from the chemical
Special protective equipment and precautions for firefighters
Fire fighting equipment/instructions
Specific methods
General fire hazards
This product is a multi-component mixture of fragrance ingredients. The specific chemical identities of the ingredients not listed herein are considered to be trade secrets by the manufacturer and are withheld in accordance with the provisions of 29 CFR 1910.1200.
Under normal conditions of intended use, this material is not expected to be an inhalation hazard. Call a physician if symptoms develop or persist. Move to fresh air.
Wash with soap and water. In case of eczema or other skin disorders: Seek medical attention and take along these instructions.
Flush eyes immediately with large amounts of water. Get medical attention if irritation develops and persists.
Rinse mouth. Do not induce vomiting without advice from poison control center. If vomiting occurs, keep head low so that stomach content doesn't get into the lungs. Get medical attention if symptoms occur.
May cause an allergic skin reaction. Dermatitis. Rash. Direct contact with eyes may cause temporary irritation.
Provide general supportive measures and treat symptomatically. Symptoms may be delayed. Keep individual under observation.
Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. Show this safety data sheet to the doctor in attendance.
Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).
Do not use water jet as an extinguisher, as this will spread the fire.
During fire, gases hazardous to health may be formed.
Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Use water spray to cool unopened containers.
Use standard firefighting procedures and consider the hazards of other involved materials.
No unusual fire or explosion hazards noted.
6. Accidental release measures
Personal precautions, protective equipment and emergency procedures
Methods and materials for containment and cleaning up
Environmental precautions
Provide adequate ventilation and avoid contact with skin and eyes. Wear appropriate protective equipment and clothing during clean-up. For personal protection, see section 8 of the SDS. Local authorities should be advised if significant spillages cannot be contained. Remove all sources of ignition.
Sweep up and shovel into suitable containers for disposal. Contain the spill, then place in a suitable container. Collect and dispose of spillage as indicated in section 13 of the SDS. For waste disposal, see section 13 of the SDS. Prevent product from entering drains.
Avoid release to the environment. If large quantities enter a waterway, advise local authorities.
7. Handling and storage
Precautions for safe handling
Conditions for safe storage, including any incompatibilities
Avoid contact with eyes, skin, and clothing. Provide adequate ventilation. When using, do not eat, drink or smoke. Do not taste or swallow. Wear appropriate personal protective equipment. Avoid release to the environment.
Keep containers tightly closed and dry. Store in a cool well ventilated area away from incompatible materials. Keep away from direct sunlight. Keep away from heat, sparks and open flame. Keep out of the reach of children. Store locked up. Metal containers must be lined. Storage 32-90°F (0-32.2°C) for less than 30 days. Optimal conditions for long term storage 60-75°F (15.5-23.8°C). Acceptable conditions for long term storage 40-80°F (4.4-26.6°C).
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
SDS US
2 / 7
8. Exposure controls/personal protection
US ACGIH Threshold Limit Values: Time Weighted Average (TWA): mg/m3, non-standard units
US. ACGIH Threshold Limit Values
US. NIOSH: Pocket Guide to Chemical Hazards
wash work clothing and protective equipment to remove contaminants.
Occupational exposure limits
Type
2,6-DI-TERT-BUTYL-P-CR ESOL
(CAS 128-37-0)
TWA 2 mg/m3 Inhalable fraction and
Type
TWA 20 ppm.ALPHA.-PINENE (CAS 80-56-8) CITRAL
TWA 5 ppm Inhalable fraction and (CAS 5392-40-5)
TWA 10 mg/m32,6-DI-TERT-BUTYL-P-CR ESOL
(CAS 128-37-0)
Biological limit values
No biological exposure limits noted for the ingredient(s).
Exposure guidelines
US ACGIH Threshold Limit Values: Skin designation
CITRAL (CAS 5392-40-5) Can be absorbed through the skin.
Appropriate engineering
General ventilation normally adequate.
controls
Individual protection measures, such as personal protective equipment
Eye/face protection
Wear safety glasses or goggles if handling large quantities.
Skin protection
Hand protection
Other
In case of prolonged or frequently repeated contact, wear appropriate gloves.
None necessary under normal conditions of use. Wear appropriate gloves if handling large quantities.
Respiratory protection
Thermal hazards
General hygiene considerations
Under normal conditions of use respiratory protection is not expected to be required.
Not applicable.
When using, do not eat, drink or smoke. Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely
ValueConstituents
Form
vapor.
ValueConstituents
Form
vapor.
ValueConstituents Type
9. Physical and chemical properties
Appearance
Physical state
Form
Color
Odor
Odor threshold
pH
Melting point/freezing point
Initial boiling point and boiling range
Flash point
Evaporation rate
Flammability (solid, gas)
Upper/lower flammability or explosive limits
Flammability limit - lower (%)
Flammability limit - upper (%)
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
Solid.
Solid
Clear
Lavender
Not available.
Not available.
140 - 185 °F (60 - 85 °C)
Not available.
> 199.4 °F (> 93.0 °C)
Not available.
Not available.
Not available.
Not available.
SDS US
3 / 7
Explosive limit - lower (%)
Inhalation
Skin contact
Eye contact
Ingestion
Acute toxicity
Respiratory sensitization
Carcinogenicity
Explosive limit - upper (%)
Vapor pressure
Vapor density
Relative density
Solubility(ies)
Solubility (water)
Partition coefficient (n-octanol/water)
Auto-ignition temperature
Decomposition temperature
Viscosity
10. Stability and reactivity
Reactivity
Chemical stability
Possibility of hazardous reactions
Conditions to avoid
Incompatible materials
Hazardous decomposition products
Not available.
Not available.
Not available.
Not available.
Not available.
Insoluble
Not available.
> 626 °F (> 330 °C)
> 572 °F (> 300 °C)
Not available.
The product is stable and non-reactive under normal conditions of use, storage and transport.
Material is stable under normal conditions.
No dangerous reaction known under conditions of normal use.
Avoid temperatures above 210 °C. Heat, flames and sparks. Extremes of temperature and direct sunlight.
Strong oxidizing agents.
Carbon dioxide, carbon monoxide, and unburned hydrocarbons.
11. Toxicological information
Information on likely routes of exposure
Health injuries are not known or expected under normal use.
May cause an allergic skin reaction.
Direct contact with eyes may cause temporary irritation.
Not applicable under normal conditions of use. May cause gastrointestinal irritation if ingested.
Symptoms related to the physical, chemical and toxicological characteristics
Information on toxicological effects
GP PRO ActiveAire® Urinal Screen, Lavender
Acute
Inhalation
LC50 Rat 4957 mg/l/4h estimated
* Estimates for product may be based on additional component data not shown.
Skin corrosion/irritation
Serious eye damage/eye irritation
Respiratory or skin sensitization
ACGIH sensitization
.ALPHA.-PINENE (CAS 80-56-8) Dermal sensitization CITRAL (CAS 5392-40-5) Dermal sensitization
Skin sensitization
Germ cell mutagenicity
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
May cause an allergic skin reaction. Dermatitis. Rash. Direct contact with eyes may cause temporary irritation.
May cause an allergic skin reaction.
Prolonged skin contact may cause temporary irritation.
Direct contact with eyes may cause temporary irritation.
Not classified.
May cause an allergic skin reaction.
No data available to indicate product or any components present at greater than 0.1% are mutagenic or genotoxic.
This product is not considered to be a carcinogen by IARC, ACGIH, NTP, or OSHA.
Test ResultsProduct Species
SDS US
4 / 7
IARC Monographs. Overall Evaluation of Carcinogenicity
Aspiration hazard
Chronic effects
warnings even after container is emptied.
Not listed.
OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050)
Not regulated.
US. National Toxicology Program (NTP) Report on Carcinogens
Not listed.
Reproductive toxicity
Specific target organ toxicity ­single exposure
Specific target organ toxicity ­repeated exposure
Not classified.
Not classified.
Not classified.
Not applicable.
Not hazardous under normal conditions of use.
12. Ecological information
Ecotoxicity
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Other adverse effects
Harmful to aquatic life with long lasting effects.
No data is available on the degradability of this product.
No data available.
No other adverse environmental effects (e.g. ozone depletion, photochemical ozone creation potential, endocrine disruption, global warming potential) are expected from this component.
13. Disposal considerations
Disposal instructions
Local disposal regulations
Hazardous waste code
Waste from residues / unused products
Contaminated packaging
This product, if discarded, is not considered a hazardous waste under Federal Hazardous Waste Regulations 40 CFR 261. If processing, use, or contamination alters the material, the waste must be tested using methods described in 40 CFR 261 to determine if it meets applicable definitions of hazardous wastes. Do not incinerate used or unused product.
Dispose in accordance with all applicable regulations.
The waste code should be assigned in discussion between the user, the producer and the waste disposal company.
Dispose of in accordance with local regulations. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions).
Do not re-use empty containers. Empty containers should be taken to an approved waste handling site for recycling or disposal. Since emptied containers may retain product residue, follow label
14. Transport information
DOT
Not regulated as dangerous goods.
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not available.
15. Regulatory information
US federal regulations
TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D)
Not regulated.
CERCLA Hazardous Substance List (40 CFR 302.4)
Not listed.
SARA 304 Emergency release notification
Not regulated.
OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050)
Not regulated.
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.
SDS US
5 / 7
Superfund Amendments and Reauthorization Act of 1986 (SARA)
A "No" indicates that one or more components of the product are not listed or exempt from listing on the inventory administered by the governing
Hazard categories
Immediate Hazard - Yes Delayed Hazard - No Fire Hazard - No Pressure Hazard - No Reactivity Hazard - No
SARA 302 Extremely hazardous substance
Not listed.
SARA 311/312 Hazardous
Yes
chemical
SARA 313 (TRI reporting)
Not regulated.
Other federal regulations
Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List
Not regulated.
Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130)
Not regulated.
Safe Drinking Water Act
Not regulated.
(SDWA)
US state regulations
US. California Controlled Substances. CA Department of Justice (California Health and Safety Code Section 11100)
Not listed.
US. Massachusetts RTK - Substance List
.ALPHA.-PINENE (CAS 80-56-8) 2,6-DI-TERT-BUTYL-P-CRESOL (CAS 128-37-0)
US. New Jersey Worker and Community Right-to-Know Act
.ALPHA.-PINENE (CAS 80-56-8) 2,6-DI-TERT-BUTYL-P-CRESOL (CAS 128-37-0)
US. Pennsylvania Worker and Community Right-to-Know Law
.ALPHA.-PINENE (CAS 80-56-8) 2,6-DI-TERT-BUTYL-P-CRESOL (CAS 128-37-0)
US. Rhode Island RTK
Not regulated.
US. California Proposition 65
California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65): This material is not known to contain any chemicals currently listed as carcinogens or reproductive toxins.
International Inventories
Country(s) or region Inventory name On inventory (yes/no)*
*A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s)
YesUnited States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory
country(s).
16. Other information, including date of preparation or last revision
Issue date
Version #
HMIS® ratings
NFPA ratings
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
April-28-2016
01
Health: 2 Flammability: 1 Physical hazard: 0
Health: 2 Flammability: 1 Instability: 0
SDS US
6 / 7
Disclaimer
This SDS is intended to quickly provide useful information to the user(s) of this material or product. It is not intended to serve as a comprehensive discussion of all possible risks or hazards, and it assumes a reasonable use of the product. The information contained in this SDS is believed to be accurate as of the date of preparation of this SDS and has been compiled from sources believed to be reliable. It is offered for your consideration, investigation and verification. The user or handler (or their employer) should consider the specific conditions in which this material will be used, handled, or stored and determine what specific safety or other precautions are required. Employers should ensure that their employees, agents, contractors, and customers who will use the product receive adequate warnings and safe handling procedures, including a current SDS. Product users or handlers (or their employer) who are unsure of what specific precautions are required should consult their employer, product supplier, or safety or health professionals before handling or working with this product. Please notify us immediately if you believe this SDS or other safety and health information about this product is inaccurate or incomplete.
Material name: GP PRO ActiveAire® Urinal Screen, Lavender
5515 Version #: 01 Issue date: April-28-2016
SDS US
7 / 7
Loading...