Actiiv ACMMD001 User Manual

WRIST BLOOD PRESSURE MONITOR
User Manual
Thank you very much for selecting the Actiiv Wrist Blood Pressure Monitor ACMMD001.
Please read the user manual carefully and thoroughly so as to ensure the safe usage of this product, and keep the manual for further reference in case you have problems.
MODEL: ACMMD001
Table of Contents
Table of Contents
INTRODUCTION...............................................................................................................
General Description Measurement Principle Safety Information Indications for Use LCD Display Signal Monitor Components
BEFORE YOU START...................................................................................................... 6
Charging your Device Setting Date and Time
MEASUREMENT
Positioning the Cuff Pair up the Blood Pressure Monitor with your Device Start Measurement
DATA MANAGEMENT.......................................................................................................
Recall the Records Delete the Records
INFORM ATION FOR USER............................................................................................... 15
Tips for Measurement Maintenance
ABOUT BLOOD PRESSURE............................................................................................. 17
What are systolic pressure and diastolic pressure?
What is the standard blood pressure classification?
Why does my blood pressure vary, even in one day? Why is the blood pressure I get from the hospital different from home? Will I get the same result if I measure on the right wrist?
TROUBLESHOOTING...................................................................................................... 19
SPECIFIC ATIONS............................................................................................................ 20
THE MATCHED COMPONENTS...................................................................................... 21
CONTACT INFORMATION............................................................................................... 21
COMPLIED EUROPEAN STANDARDS LIST.................................................................... 22
EMC GUIDANCE.............................................................................................................. 23
APPENDIX........................................................................................................................ 24
..............................................................................................................
2
9
13
INTRODUCTION
General Description
Thank you for selecting the Actiiv blood pressure Monitor (ACMMD001 .) The monitor featu res bl ood press ure measurement, pul se rate measurement and storage of results.
Readings taken by the device are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method. This manual contains important safety and care information, and provides step by step instructions for using the product.
Please read this user manual carefully and thoroughly before use.
FEATURES:
Systolic Blood Pressure
Diastolic Blood Pressure
Measurement Principle
This product uses the Oscillometric Measuring Method to detect blood pressure. Before every measurement, the unit establishes a “zero point” equivalent to the
atmospheric pressure. Then it starts inflating the cuff. Meanwhile, the unit detects
pressure oscillation generated by beat-to-beat pulsatile, which is used to deter­mine the systolic pressure and diastolic pressure as well as pulse rate. The device also compares the longest and the shortest intervals of detected pulse wave with the average value, and then calculates the standard deviation. The monitor will light up a warning symbol when the calculated standard deviation is larger than or equal to 15.
Pulse Rate Memory: Up to 60 readings can be
recorded
Safety information
The below signs might appear in the user manual, labeling or other components.
Symbol for “THE OPERATION GUIDE MUST BE READ”
For indoor use only
The Bluetooth Combination Mark
F1
Symbol for “TYPE BF APPLIED PARTS”
Symbol for “DIRECT CURRENT”
T1A/250V Φ3.6*10CCC
INTRODUCTION
Indications for use
The Actiiv Blood Pressure Monitor is a digital monitor intended for use in measuring blood pressure and heartbeat rate with a wrist circumference ranging from 13.5 cm to 21.5 cm ( about 5-8.5 inches ). It is intended for adult indoor use only.
CAUTION
* It is intended for adult indoor use only. Pregnant women, pre-eclamptic patients and patients with severe obesity should not use this device. If required, please consult a professional doctor.
* This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is not intended for use on extremities other than the wrist or for functions other than obtaining a blood pressure measurement.
* Please use the device under the specified environment as instructed in this user manual, otherwise the accuracy of the device will be influenced.
* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure. Please only start or end any medical treatments based solely on a physician's treatment advice. * If you are taking medication, consult your physician to determine the most appropriate time for your measurement. Never change a prescribed medication without your physician’s consent. * This unit is not suitable for continuous monitoring during medical emergencies or operations.
After the cuff has been inflated for a long time, the patient’s wrist and fingers blood supply will become insufficient and could result in distending pain and ecchymosis. * If the pressure of the cuff exceeds 40 kPa (300 mmHg), the unit will automatically deflate. If the cuff doesn’t deflate when its pressure exceeds 40 kPa (300 mmHg), detach the cuff from the wrist and press the START/STOP button to stop inflation. * Do not use the monitor under strong electromagnetic field conditions (e.g. medical RF equipment)
that radiate an interference signal or electrial fast transient/ burst signal. * The maximum temperature that the applied part can achieve is 42.5 ℃ while the environmental temperature is 40℃.
* The device is not AP/APG equipment. It is not suitable for use in the presence of a flammable
anesthetic mixture with air (or oxygen, nitrous oxide). * Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of small parts is dangerous or even fatal.
* Please use the accessories and detachable parts as specified and authorised by the manufacturer.
Otherwise, it may cause damage to the unit or danger to the user / patient. * The patient is an intended operator. The patient can measure, transmit data and charge the battery under normal circumstances and maintain the device and its accessories according to the user manual. * The blood pressure monitor, its adaptor, and the cuff are suitable for use within the patient environment. If you are allergic to dacron or plastic, please don’t use this device. *This device cannot be used with HF surgical equipment at the same time.
* There is a PTC current limiter in the monitor, with a specification of 8V and 0.5A. When the voltage
and current exceed the limiting value, the monitor will stop working. * The device is not suitable for public use.
INTRODUCTION INTRODUCTION
LCD Display Signal
Systolic Blood Pressure
Diastolic Blood Pressure
Pulse beat/minute
Low Battery
Unit Measurement unit of blood pressure
IHB Detector
Bluetooth Successful Bluetooth Connection
Error
Memory
Time
4
High blood pressure
Low blood pressure
Please use the USB cable provided to recharge the battery.
Irregular Heartbeat Detector
Error
Recalling the history records
Hour:Minute (Month/Day/Year)
Monitor Components
MEM/UP BUTTON
SET
MEM
SET/DOWN BUTTON
List
1.Blood Pressure Monitor (ACMMD001)
3.User Manual
2.USB Cable
SYSTOLIC
DIASTOLIC
PULSE RATE
TIME
START/STOP BUTTON
CUFF (Type BF applied part)
USB Interface
5
BEFORE YOU START BEFORE YOU START
Power Supply and Charge Power
1. The battery for ACMMD001 is a built-in rechargeable lithium-ion battery, with a current of 420 mAh.
2. Please use the USB cable provided to charge the battery just like the picture below:
Your device will require charging under the following circumstances:
displays on the LCD
The LCD display dims
When powering on the monitor, the LCD doesn’t light up.
CAUTION
1. The battery used is a built-in rechargeable lithium-ion battery, please do not disassemble it by an unauthorized maintenance personel.
2. Under normal use, it can be charged about 300 times. If measured three times per day, and the battery
is fully charged, it can be used for about 20 days.
3. Store and use the blood pressure monitor in a cool, dry and
ventilated environment. Avoid close proximity to fire and heat sources or it
may cause the battery explode.
4.
You cannot use the blood pressure monitor during the charging process.
5. During the process of charging, the blood pressure monitor will display this symbol:
When charging is complete, please remove plug before use.
6. When charging, do not touch the charging connector and the patient simultaneously.
6
Setting Date and Time
Please proceed to set the time before your initial use to ensure each record is labelled with a time stamp. (Year Range: 2012-2052; Time Format: 12 Hours)
1.When the monitor is OFF, press and hold the “SET” button for 3 seconds to enter Time Setting Mode.
2.As pictured in the right, the
blinking number “12” representing [HOUR]. Press “MEM” button to change the number. Each press will increase the number by one in a cycling manner.
3.Press “SET” button again to
confirm [HOUR]. Then the
number representing [MINUTE] blinks.
7