ACTi R11C-30 Quick Start Guide

Readers & Controllers Quick Installation Guide
R11C-30
2020/03/23
Quick Installation Guide
Table of Contents
Part 1: Installation and Wiring ............................... 3
Installation ................................................................................................ 3
Cabling Instructions ................................................................................. 4
Connectors Diagram ............................................................................. 4
Wiring Instructions ................................................................................ 6
Part 2: Basic Settings ............................................. 8
Step 1: Go to SETTINGS .......................................................................... 8
Step 2: Set the Language ........................................................................ 9
Step 3: Change Password ...................................................................... 11
Part 3: Other Configurations ................................ 12
Configure IP Address ............................................................................. 12
Configure RELAY ................................................................................... 16
Restore to Default Factory Settings ..................................................... 18
2
Quick Installation Guide
Thank you for using ACTi Reader. This documentation contains basic settings of your device. If you wish to add users, it is recommended to add users through the Access Control Standard Server (ACSS). For more information, please refer to the ACSS manual.
Part 1: Installation and Wiring
Installation
Attach the waterproof strip to the mounting plate. Pull the cables from the square hole of the mounting plate. Use a screwdriver to screw the base onto the wall. Connect the terminal cables to the body and attach the body to the
mounting plate.
Assemble the covers with the bundled Allen key and scres. Turn on the power, the LED will light and a beep will sound, you will see
Ready” on the LCD screen.
3
Cabling Instructions
Wire Application
Wire
Color
Description
Lock Relay
1
Blue - White
Normal On (N.O.)
2
Purple – White
Normal Close (N.C.)
Lock Relay COM
3
White
COM
Door Contact
4
Orange
Negative Trigger Input
Exit Switch
5
Purple
Negative Trigger Input
Alarm Relay
6
Gray
DC24V1Amp
Power
7
Red
DC 12V
8
Black
DC 0V
Connectors Diagram
Cable: CN4 (Main cable)
Quick Installation Guide
4
Quick Installation Guide
Wire Application
Wire
Color
Description
Beeper
1
Pink
Beeper Output 5V/100mA, Low
LED
2
Yellow
Red LED Output 5V/20mA, Max
3
Brown
Green LED Output 5V/20mA, Max
Door Output
4
Blue – White
Transistor Output Max. 12V/100mA (Open collector Active Low)
Wiegand
5
Green
Wiegand DAT: 0 Input
6
Blue
Wiegand DATA: 1 Input
WG Door Contact
7
Orange
Negative Trigger Input
WG Door Switch
8
Purple
Negative Trigger Input
Wire Application
Wire
Color
Description
1
---
---
2
---
---
TCP/IP Output
3
Orange-White
Net - TX+
4
Orange
Net - TX-
5
Green - White
Net - RX+
6
Green
Net - RX-
7
---
---
Cable: CN5 (Wiegand DI/DO Wiring)
Cable: CN7 (Network Wiring)
5
Quick Installation Guide
EXIT
Exit Switch
GND
N.O.
Exit PB
0V
12V
DC 12V
DC 0V
CN4
1
2
3
4
5
6
7
8
N.O.
COM
12V
0V (GND) )
PB
R11C-30
DC 12V
DC 0V
Wiring Instructions
A. Connecting the Reader / Controller and Exit Switch
Electric Lock
6
Loading...