Acson ART 55 A, ART 60 A, ART 80 A, ART 100 A, ART 120 A user guide manual

...
ART 55 A/AR ART 60 A/AR ART 80 A/AR ART 100 A/AR ART 120 A/AR ART 150 A/AR ART 200 A/AR ART 250 A/AR ART 300 A/AR ART 360 A/AR ART 420 A/AR
A4RT 60 A/AR A4RT 80 A/AR A4RT 100 A/AR A4RT 120 A/AR A4RT 150 A/AR A4RT 200 A/AR A4RT 250 A/AR A4RT 300 A/AR A4RT 360 A/AR
A4RT 420 A/A
R
ART-A_(i)
Rooftop Packaged
Air Conditioners
TABLE OF CONTENTS
1. NOMENCLATURE.......................................................................................................... 1
- PRODUCT LINE-UP
2. FEATURES..................................................................................................................... 4
3. APPLICATION INFORMATION........................................................................................ 5
- OPERATING RANGE
- REFRIGERANT CIRCUIT DIAGRAMS
- CONTROLLERS
- PRECAUTION AND INSTALLATION
4. SOUND DATA............................................................................................................... 43
5. SELECTION PROCESS...............................................................................................49
- FAN PERFORMANCE CHART
6. ENGINEERING & PHYSICAL DATA............................................................................63
- GENERAL DATA
- COMPONENTS DATA
- SAFETY DEVICES
7. PERFORMANCE DATA..............................................................................................105
- PERFORMANCE TABLE
8. OUTLINE AND DIMENSION.......................................................................................137
9. ELECTRICAL DATA....................................................................................................143
10. WIRING DIAGRAMS...................................................................................................155
11. SERVICING AND MAINTENANCE.............................................................................170
12. TROUBLESHOOTING................................................................................................173
13. EXPLODED VIEW & PART LIST.............. ..................................................................178
This manual supercedes ART-2009
A RT 100 AR - FX AA
Series
A: A series
Model Type
R: Heatpump Blank: Cooling Only
Capacity
100: 100,000 Btu/h
Model Name
RT: Rooftop
Brand
A: Acson
Electrical
F: 380-415V/3Ph/50Hz
Type of ref. connection
X: Not Applicable
Production spec variation
4
Refrigerant
4: R407C Blank: R22
1. NOMENCLATURE
1
Product Line-up
FXBA
FXBC
FXBA
FXBC
FXBB
FXBC
FXBA
FXBD
FXBA
FXBD
A(4)RT Cooling Only
Classification
A4RT
ART
Model
Cooling Only
60A FXAB 60A FXAD 80A FXAA XXXXXXXXX 80A FXAC XXXXXXXX 100A FXAA XXXXXXXX 100A FXAC XXXX 120A FXAB XXXXXXXX 120A FXAC XXXXXXXX
150A FXAA X XXXXXXX 150A FXAD X XXXXXXX 200A FXAA X XXXXXXX 200A FXAD X XXXX 250A FXAA XXXX XX 250A FXAC XXXX XX 300A FXAA XXXX XX 300A FXAC XXXX XX 360A FXAC XXX 420A FXAC XXXXX XX 55A FXAI XXXX XX 60A FXAH XXXXXXX 60A FXAI XXXXXXX 80A FXBC X X X X X X 80A FXBH X X X X X X 80A FXBI X X X X X X X X 80A FXBN X X X X X X X 100A FXBC X X X X X X 100A FXBH X X X X X X 100A FXBI X X X X X X X X 100A FXBN X X X X X X X 120A FXBH X X X X X X X X 120A FXBI X X X X X X X X 150A FXBC X X X X X X X 150A FXBH XX X X X X 150A FXBI X X X X X X X X 150A FXBN X X X X X X X 200A FXBC X X X X X X 200A FXBH X X X X X X 200A FXBI X X X X X X X X 200A FXBN 250A FXAA XXXXXXX 250A FXAD XXXXXXX 250A FXAH XXXXX XX 300A FXAA XXXXXXX 300A FXAD XXXXXXX 300A FXAH XXXXX XX 360A FXAA XXXXXXX 360A FXAH XXXXX XX 420A FXAA XXXXXXX 420A FXAH XXXXX XX
Nomenclature
SLM Controller
XXX XXX
X X X
Seq. Controller
Capil lary Tube
Thermal Expansion Valve (TXV)
Normal Fin
Gold (NA549) Fin
X
X
X
X
X
Scroll Compressor
Air Filter
Down Flow
XX XX
XX XXX
XXXX
XX XX
X X X X
Side Flow
XX XX
Convertible
Filter Drier
2
A(4)RT Heat Pump
SLM Controller
Seq. Controller
Capillary Tube
Thermal Expansion Valve (TXV)
Normal Fin
Gold (NA549) Fin
Reciprocating Compressor
Scroll Compressor
Air Filter
Down Flow
Side Flow
Convertible
Filter Drier
60AR FXAC XXXXXXX
80AR FXAC XXXXX XXX 100AR FXAC XXXXX XXX 120AR FXAC XXXXX XXX 150AR FXAC XXXXX XXX 200AR FXAC XXXXX XXX 250AR FXAC XXXXXXX 300AR FXAC XXXXXXX 360AR FXAC XXXXXXX 420AR FXAC XXXXXXX
55AR FXAI XXXXXX
60AR FXAH XXXXXXX
60AR FXAI XXXXXXX
80AR FXAC XXXXXX
80AR FXAH XX XX XX
80AR FXAN XXXXXXX 100AR FXAC XXXXXX 100AR FXAH XX XX XX 100AR FXAN XXXXXXX 120AR FXAH XXXXX XXX 120AR FXAI XXXXX XXX 150AR FXAC XX XXXX 150AR FXAH XX XX XX 150AR FXAN XX XXXXX 200AR FXAC XX XXXX 200AR FXAH XX XX XX 200AR FXAN XX XXXXX 250AR FXAA XXXXXXX 250AR FXAD XXXXXX X 250AR FXAH XXXXXXX 300AR FXAA XXXXXXX 300AR FXAD XXXXXX X 300AR FXAH XXXXXXX 360AR FXAH XXXXXXX 420AR FXAH XXXXXXX
ART
Nomenclature
Classification
A4RT
Model
Heat Pump
FXBC
FXBC
FXBC
FXBC
FXBC
FXBH
FXBC
FXBN
FXBC
FXBH
FXBN
FXBH
FXBI
FXBH
FXBC
FXBN
FXBC
FXBH
FXBN
3
Thank you for evaluating Wondershare PDF Password Remover.