Acrosser AR-B104B User Manual

AR-B104B User Manual
AR-B104B_4P/8P, PCI104 COM
RS232/RS485/ Full duplex with Isolation and ESD protect
User Manual
1
2009/1/15
Revision
Version Date Author Description
AR-B104B User Manual
0.1
0.2 2009/2/3 Judy Tseng Revise
1.0 2009/2/4 Marc Chung Release
1.1 2010/10/18 Kenny Lee OXmPCI954 change to
Marc Chung Draft
OXuPCI954
2
AR-B104B User Manual
Copyright 2009
All Rights Reserved.
Manual’s first edition:
For the purpose of improving reliability, design and function, the information in this document is subject to change without prior notice and does not represent a commitment on the part of the manufacturer.
In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
This document contains proprietary information protected by copyright. All rights are reserved. No part of this Manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
Trademarks
AR-B104B is a registered trademarks of Acrosser; IBM PC is a registered trademark of the International Business Machines Corporation; Pentium is a registered trademark of Intel Technologies Inc; Award is a registered trademark of Award Software International Inc; other product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
3
AR-B104B User Manual
Contents
1 Introduction ......................................................................... 5
1.1 Specifications................................................................................................... 6
1.2 Package Contents ............................................................................................ 7
1.3 Block Diagram .................................................................................................. 8
2 AR-B104B H/W Information .................................................. 9
2.1 Connectors and Jumpers Setting................................................................... 9
2.2 Connectors and Jumpers Pin Define ........................................................... 11
3 OXuPCI954 Drive Installation Guide .................................. 15
4
AR-B104B User Manual
1 Introduction
Welcome to the AR-B104B_4P/8P PCI104 COM PORT. The AR-B104B_4P/8P is the PCI 104 compliant that compatible with 16C550 performance UART channel and supports all RS-232C transceiver mode. Maximum baud rate is to 115.2Kbps in asynchronous mode.
The AR-B104B_4P/8P is a Complete Platform that totally supports 4 UART channels(AR-B104B/4P), could option to 8 channel(AR-B104B/8P)
5
AR-B104B User Manual
1.1 Specifications
Module Name: AR-B104B/4P or 8P.  Dimension: 90.2mm x 95.9mm.  Controller: Oxford OXuPCI954.  RS232: Isolation 2KV and ESD contact 8KV air 15KV protect.  Function selectable: RS232/RS485/RS422 selectable by jumper  System Interface: PCI Local bus specification V3.0 in PCI-104 format  Connector: 2 x 22 2.0mm pin head 180 degree.  Operation Temperature: AR-B104B/4P: -20 to 85℃;AR-B104B/8P: -20 to
70. Support: OS Windows XP/XPE, Linux FC6/FC7.
6
1.2 Package Contents
Check if the following items are included in the package. AR-B104B_4P Packing List:
AR-B104B_4P  2.0mm 2x22 Pin header to 4 x DB9 cable  1 software utility CD  Gift Box  User Manual
AR-B104B_8P Packing List:
AR-B104B_8P  2.0mm 2x22 Pin header to 4 x DB9 cable  2.0mm 2x22 Pin header to DB37 cable  DB37 to 4 x DB9 cable  1 software utility CD  Gift Box
AR-B104B User Manual
User Manual
7
1.3 Block Diagram
AR-B104B User Manual
8
AR-B104B User Manual
2 AR-B104B H/W Information
This chapter describes the installation of AR-B104B. At first, it shows the function diagram and the layout of AR-B104B. It then describes the unpacking information which you should read carefully, as well as the jumper/switch settings for the AR-B104B configuration.
2.1
Connectors and Jumpers Setting
9
COM
8 transfer type select
PCI Clock and IDSEL signal select
COM5 transfer type select
COM
1 transfer type select
COM5 ~ COM8 termination enable
COM
4 t
ransfer type select
COM
6 transfer type select
COM
1 ~ COM
4 termination enable
COM
7 transfer type select
COM
3 transfer type select
OXuPCI954 for COM
5 ~ COM
8
COM
2 transfer type select
COM5 ~ COM8
output port
COM1 ~ COM4 output port
OXuPCI954 for COM1 ~ COM4
PCI 104 slot signal from M/B
PCI INT signal select
AR-B104B User Manual
JP8
JP5
JP10
JP6
JP7
UART Controller 1
COM 5~8
UART Controller 2
JP12
JP11
JP1
JP4
JP9
JP3
JP2
COM 1~4
CN1
10
2.2 Connectors and Jumpers Pin Define
AR-B104B User Manual
2.1 JP8
COM8 transfer type select
Transfer type Select
3 – 4
RS-232
(default)
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
(AR-B104B/8P Optional)
2.4 JP6
2.2 JP5
COM5 transfer type select
Transfer type Select
3 – 4
RS-232
(default)
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
(AR-B104B/8P Optional)
2.5 JP7
2.3 JP10
COM5 ~ COM8 termination enable
120R
termination enable
COM5 120R
termination enable
COM6 120R
termination enable
COM7 120R
termination enable
COM8 120R
termination enable
(AR-B104B/8P Optional)
(default)
(default)
(default)
(default)
2.6 UART Controller 1
Select
1 – 2
3 – 4
5 – 6
7 – 8
COM6 transfer type select
Transfer type Select
3 – 4
RS-232
(default)
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
(AR-B104B/8P Optional)
COM7 transfer type select
Transfer type Select
3 – 4
RS-232
(default)
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
(AR-B104B/8P Optional)
OX16C954 UART Controller for COM5~COM8
(AR-B104B/8P Optional)
11
PCI INT signal
AR-B104B User Manual
2.7 COM 5~8
COM5 ~ COM8 output port
Pin RS-232 RS-422 RS-485
1 DCD_8 N/C N/C 2 DSR_8 Rx-_8 N/C 3 RXD_8 Rx+_8 N/C 4 RTS_8 N/C N/C 5 TXD_8 N/C N/C 6 CTS_8 Tx-_8 Data-_8 7 DTR_8 N/C N/C 8 RI_8 Tx+_8 Data+_8 9 GND GND GND
10 +5V +5V +5V 11 DCD_7 N/C N/C 12 DSR_7 Rx-_7 N/C 13 RXD_7 Rx+_7 N/C 14 RTS_7 N/C N/C 15 TXD_7 N/C N/C 16 CTS_7 Tx-_7 Data-_7 17 DTR_7 N/C N/C 18 RI_7 Tx+_7 Data+_7 19 GND GND GND 20 +5V +5V +5V 21 DCD_6 N/C N/C 22 DSR_6 Rx-_6 N/C 23 RXD_6 Rx+_6 N/C 24 RTS_6 N/C N/C 25 TXD_6 N/C N/C 26 CTS_6 Tx-_6 Data-_6 27 DTR_6 N/C N/C 28 RI_6 Tx+_6 Data+_6 29 GND GND GND 30 +5V +5V +5V 31 N/C N/C N/C 32 N/C N/C N/C 33 DCD_5 N/C N/C 34 DSR_5 Rx-_5 N/C 35 RXD_5 Rx+_5 N/C 36 RTS_5 N/C N/C 37 TXD_5 N/C N/C 38 CTS_5 Tx-_5 Data-_5 39 DTR_5 N/C N/C 40 RI_5 Tx+_5 Data+_5 41 GND GND GND 42 +5V +5V +5V 43 N/C N/C N/C 44 N/C N/C N/C
2.8 UART Controller 2
OXuPCI954 UART Controller for COM1~COM4
2.9 JP12 PCI INT signal select
select
INTA
INTB 3 - 4 INTC 5 - 6 INTD 7 - 8
Select
1 – 2
(default)
12
AR-B104B User Manual
2.10 JP11
PCI Clock and IDSEL signal select
PCI INT and
IDSEL signal
select
CLK0, IDSEL 0
CLK1, IDSEL 1 CLK2, IDSEL 2 CLK2, IDSEL 3
Select
1-2, 3-4
(default)
1 - 2 3 - 4
N/A
2.11 JP1
COM1 transfer type select
Transfer type Select
RS-232
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
3 – 4
(default)
2.12 JP4
COM4 transfer type select
Transfer type Select
RS-232
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
3 – 4
(default)
2.13 JP9
COM1 ~ COM4 termination enable
120R
Termination enable
COM1 120R termination
enable
COM2 120R termination
enable
COM3 120R termination
enable
COM4 120R termination
enable
Select
1 – 2
(default)
3 – 4
(default)
5 – 6
(default)
7 – 8
(default)
2.14 JP3
COM3 transfer type select
Transfer type Select
RS-232
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
3 – 4
(default)
2.15 JP2
COM2 transfer type select
Transfer type Select
RS-232
RS-422 1 – 2, 5 - 6 RS-485 1 - 2
3 – 4
(default)
13
Pin RS-232 RS-422 RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
AR-B104B User Manual
2.16 COM 1~4
COM1~ COM4 output port
DCD_4 N/C N/C DSR_4 Rx-_4 RXD_4 Rx+_4
RTS_4 N/C N/C TXD_4 N/C N/C CTS_4 Tx-_4 Data-_4
DTR_4 N/C N/C
RI_4 Tx+_4 Data+_4 GND GND GND
+5V +5V +5V DCD_3 N/C N/C DSR_3 Rx-_3 RXD_3 Rx+_3
RTS_3 N/C N/C TXD_3 N/C N/C CTS_3 Tx-_3 Data-_3
DTR_3 N/C N/C
RI_3 Tx+_3 Data+_3 GND GND GND
+5V +5V +5V DCD_2 N/C N/C DSR_2 Rx-_2 RXD_2 Rx+_2
RTS_2 N/C N/C TXD_2 N/C N/C CTS_2 Tx-_2 Data-_2
DTR_2 N/C N/C
RI_2 Tx+_2 Data+_2 GND GND GND
+5V +5V +5V
N/C N/C N/C
N/C N/C N/C DCD_1 N/C N/C DSR_1 Rx-_1 RXD_1 Rx+_1
RTS_1 N/C N/C TXD_1 N/C N/C CTS_1 Tx-_1 Data-_1
DTR_1 N/C N/C
RI_1 Tx+_1 Data+_1 GND GND GND
+5V +5V +5V
N/C N/C N/C
N/C N/C N/C
N/C N/C
N/C N/C
N/C N/C
N/C N/C
2.17 CN1
PCI 104 slot signal from M/B
14
AR-B104B User Manual
3 OXuPCI954 Drive Installation Guide
When you install the OXuPCI954 drivers in AR-B104B, you only need to install driver follow step1 to step9. If you want to adjust the COM port properties, you can follow step10 to step13 to adjust the COM port properties.
Installation Step::
1. Click the right button of mouse on “My Computer” icon, the screen will show the function list then select the “Properties” function.
15
AR-B104B User Manual
2. When “System Properties” appear on screen, select “Hardware” item.
3. In “Hardware” Setting, select “Driver Signing” item, “Driver Signing Options” screen will appear.
16
4. Select “Ignore” item, select “OK”.
AR-B104B User Manual
5. In “Hardware” Setting, select “Device Manager”
17
?
?
6. You must confirm “?
PCI Serial Port” and “?
in system devices list (When you use AR-B104B/4P, only “?
?
?
Other PCI Bridge Device” device exist
?
?
AR-B104B User Manual
PCI Serial Port” exists).
7. Now, execute the installation program of driver, then slect “OK”, the OXuPCI954 driver will be auto installation.
18
8. When the auto installation driver install finish, select “OK”.
AR-B104B User Manual
9. You can see 8 “Enhanced Communication Port” be added (When you use AR-B104B/4P, only 4 “Enhanced Communication Port” exist).
19
AR-B104B User Manual
10. If you want adjust the COM port setting, click the right button of mouse on the COM port icon.
11. Select the “Properties” function.
20
AR-B104B User Manual
12. When the COM Port icon Properties appear on screen, select “Settings” item.
13. When the properties of the COM Port icon appear on screen, select the item which you want to change, such as the sequence of the COM Port, if you setup the COM Port finish, select “OK”, the setting will be changed.
21
Loading...