SP850 Security System
Features
• 6 EOLR supervised zones
• Entry/exit timers can be assigned to separate zones
• Real time clock
• Last event alarm memory
• 2 on board programmable outputs plus bell output
• Up to eight user codes with opening/closing by user
• Automatic Test Timer for initiating a self test or a call for
downloading
• Two methods of programming:
1. Program locally from the keypad;
2. Download from ScanPro software
• Answering machine Bypass and Built-in Ring Count circuitry
allows unattended uploading/downloading
DOB Data Output Board
The optional DOB board provides eight additional open
collector outputs to the basic control panel. Programmable
outputs are:
• Remote Buzzer
• Door Strike
• Strobe light output
• Courtesy
• Arm/Alarm
• Ready/Trouble
• Smoke Power
• Fire/Burg Bell
Description
The Arrowhead SP850 is a six zone, control panel/digital
communicator security system. The SP850 may be keypad
programmed or remotely downloaded from IBM-compatible
computers using ScanPro Downloader software. The ScanPro
software provides remote panel operation and system status
information. The SP850 comes in a steel enclosure and is
compatible with the optional KP600F LED or KP600L LCD/
alphanumeric keypad.
Two programmable open collector outputs are included for
Remote Buzzer, Door Strike, Strobe Light, Courtesy , Arm/
Alarm Status, Ready/Trouble Status, Smoke Power , Fire/
Burglary Bell or Single Bell assignments.
The SP850 readily converts from Keypad to Key Switch
configuration.
"Defeat Auto Lockout" feature for arming with E/E or
Follower zones violated.
Built-in Digital Communicator
The communicator reports all standard pulse reporting
formats, Silent Knight 4 + 2, Ademco Highspeed, and Arrowhead ScanPro.
KP600F Keypad
KP600L Keypad
UL Household Burglary/Fire
Downloaded from: http://www.guardianalarms.net
Keypad Controlled User Functions
• Arming/Disarming
• Bypassing zones or zone groups
• System test
• Four emergency 24-hour programmable functions
• Duress
• Smoke detector reset
• Chime feature
• Set time/date
• Fault Analysis: AC Loss, Low Battery, Zone Trouble, Failure
to Communicate
Digital Communicator Features
• Split reporting up to three 20-digit telephone number with
three separate account numbers
• Three or four digit account numbers
• Opening/closing reports up to 8 users
• Programmable reporting attempts
• Failure to communicate annunciation at keypad
• Zone bypass, Test time reporting
• Silent Knight 4+2; standard pulse reporting formats
• ScanPro FSK formats, 300-baud software available
• Alarm, Trouble, Restoral reports by zone
• Remotely shut down nonpaying accounts
• Remote high speed up/downloading from IBM-compatible
Programmable Software Features
• "Follower" zones
• 2 Assignable outputs
• Opening/closing reports
• Automatic test report to any combination of 3 phone numbers
• Dynamic low battery/restoral reporting; programmable
reporting delays
• False alarm shutdown
• Software delete of EOL resistors
• Call back security
Specifications
Input power requirements: 16.5 - 18VAC, 20 VA
Standby battery: 12-volt battery, 7AH (NP7-12) rechargeable
gel-type, not supplied
Temperature operating range: 32o to 120o F
Auxiliary power output: 12.5VDC regulated, 500mA
Bell output: Burglary/fire output, 12.5 VDC, 500mA
Loop Response: 10 - 300mSec. (1 second when dialing)
Maximum loop resistance: Not to exceed 300 Ohms on any
loop (does not include EOL resistor)
Transient and lightning protection: Lightning and surge
protection on all input, power and telephone lines
Dimensions: 13"H x 9"W x 3"D
Shipping weight: 10 lbs.
FCC registration number: 4T2USA-24862-AL-E
Ringer Equivalence: 0.2B
Compliance: UL Listed
Order Information
SP850: SP850 control packaged with EOL resistors, spare fuses
and metal enclosure.
KP600F Keypad: Digital arming station that allows full system
status. 7 separate LEDs provide system status. Backlit keys.
Comes with back box for surface mounting.
Dimensions: 4.500” X 4.510”X 1.110”
KP600L Keypad: Alphanumeric LCD arming station that allows
full system status from one or more convenient locations. 1 line
of 16 character display zone status and alarm memory for each
zone; Ready and arm status LEDs included.
Dimensions: 6.570” X 4.670”X 1.100”
DOB: Data Output Board. One DOB may be connected to a
SP850 for special outputs.
1510 T ate Blvd. SE
Hickory, NC 28603
Sales: 800.547.2556
Technical Support: 800.800.2027
Sentrol, Inc. reserves the
right to change specifications
without notice.
© 1997 Sentrol, Inc.