ACOEM CAC1008000 User Manual

CAC1008000
Wireless accelerometer
SAFETY INSTRUCTIONS
INSTRUCTIONS DE SECURITE
INSTRUCCIONES DE SECURIDAD
INSTRUÇÕES DE SEGURANÇA
acoemgroup.com
Copyright © 2018, ACOEM
SAFETY INSTRUCTIONS
Symbol
Meaning
Warning: Whenever this symbol is present on the device, refer to the essential safety warning and instructions for use
Use a power source with limited power
(=> Mains Power supply block)
Please refer to the copy of the CE
certification data
Refer to Dismantling/recycling
The safety of the device and the user is compromised in case of use unforeseen by ACOEM.*
- Dismantling the instrument for an internal operation is forbidden. The only part for which dismantling is allowed is the hatch providing access to the USB connector
- All the spare parts must be provided by the manufacturer
Warning symbol listing
Warning: Whenever this symbol is present on the device, refer to the essential safety warning and instructions for use
General rules
- Comply with the safety instructions listed hereafter.
- Comply with the operating instructions listed in the user manual.
Verification of the overall condition
- Upon each use, check the overall condition of WLS and its accessories.
- Check that the housing is not cracked, broken or abnormally distorted.
- Check the condition of the opening plug of the USB connector.
- In case of a defect, have the defective part(s) repaired or replaced.
Electric connections
- All external circuits connected to the WLS must be non-hazardous voltage sources and be energy limited as explain in Sections 6.3 and 9.4 of Standard IEC61010-1
- Power Supply : 5 volts DC I=1A.
- Do not exceed maximum input voltage on the USB connector: maximum input voltage = 5 V DC.
- Do not exceed maximum input voltage for the power supply delivered by the mains block.
Operating environment
The device is designed to operate in the normal operating environment of IEC61010-1
altitude up to 2000 m; temperature from 5°C to 40°C; fluctuations in the voltage MAINS to ± 10% of nominal voltage; surges to levels of overvoltage category II; temporary surge occurring on the supply network; pollution rating 2.
And the following extended conditions:
outdoor use only on battery and without the charger; ambient temperatures from -10°C to 60°C; 95% non-condensing humidity
- In an industrial environment or outside, always use the instrument with the USB connector plug. Check the condition of the plug and its waterproofness at each implementation. If the plug is defective, please contact our after-sales department to have it replaced.
- In an office environment (no water splashes), WLS can be recharged by taking the plug off.
Battery
- The battery cannot be changed by the user and the instrument must be returned to the factory for battery replacement. Please contact our after-sales department for this operation.
- Do not attempt to replace the battery. This operation could affect the product safety (furthermore, metrological performances could also be affected during this operation).
- Do not open or dismount the battery pack. The pack includes essential safety protections and assembly that should in no event be modified.
- Do no place the battery into fire or close to any other temperature source (> 70°C). This action may cause overheating, even start a fire. This type of use may also lead to degraded performances and to a significantly reduced lifetime for the battery.
- Immediately disconnect the charger in the event of one of the following situations:
unusual odour  unusually high temperature
Mains power supply block
- The external power must be not dangerous and energy limited as explain in Sections 6.3 and 9.4 of the IEC61010-1 standard.
- The power supply is the main disconnect device in the system and as such should remain always perfectly accessible and disconnectable.
- The mains power block should only be used away from rain or any other water splash.
- WLS should be used away from rain or any other water splash when connected to the mains power block.
- Comply with the network power supply specifications (listed on the charger) for the power supply of the mains block.
- The charging procedure shall thus not be performed in an environment with a temperature higher than 35°C.
- During charging, the operator shall limit the presence of flammable products next to WLS and the mains power block. To connect the power supply, remove the USB plug, plug the USB plug of the block on the socket, then connect the power to the electrical outlet. Proceed in the reverse order for disconnect.
Radio
Radio (Wi-Fi) has been qualified to ensure EMC and personal
safety. This qualification is valid only with the instrument’s internal
antenna. This device complies with FCC and IC RF radiation exposure limits
set forth for general population. This device must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. IC:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This class (B) digital apparatus complies with Canadian ICES-003
Operating risks
- Since WLS is intended to be used in industrial settings, the operator shall wear required PPE (personal protective equipment) determined by the site manager.
- The use of WLS shall in no event constitute a justification for not wearing this PPE.
- In particular, the use of WLS shall in no event justify not wearing gloves if those are required by the operating regulations.
- During measurements, the operator shall specifically see to his/her own safety. In particular, he/she must ensure that he/she is not in a dangerous situation (e.g., uncertain balance when taking a measurement).
- The use of WLS shall in no event constitute a justification for taking risks that would endanger the life of the operator or of any other person.
- Using WLS implies accessing potentially dangerous machines. The operator shall make sure he/she is never in a situation where he/she could be caught or hurt by moving parts.
Storage
- Respect the storage temperature....-20°C < Tstorage < 45°C.
(Maximum storage temperature is +60°C. Storage at high temperature will lead to accelerated degradation of the battery).
- Never store the instruments and its accessories in the hot areas of a car, in particular on the dashboard. Favour shady areas, such as the rear trunk.
- Never store the instrument and its accessories under direct sunlight.
- Do not store the instrument and its accessories in a wet area.
Transport
- For air transport, follow procedure UN3481 Lithium-ion battery contained in equipment”.
Dismantling/recycling
- WLS and its accessories shall be recycled as electronic products including a battery.
- WLS and its accessories shall not be burnt or thrown into fire.
- WLS and its accessories shall not be disposed of in a dump.
INSTRUCTIONS DE SECURITE
Symbole
Signification
Attention: Chaque fois que ce symbole est présent sur l'appareil, se référer impérativement à l'avertissement de sécurité et la notice d'utilisation
Utiliser une source d'alimentation à énergie limitée (=>Bloc alimentation
secteur)
Reportez-vous à la copie du certificat
d'examen CE de type
Se référer à Démantèlement/recyclage
La sécurité de l'appareil et de l'utilisateur est compromise en cas d'utilisation non prévue par Acoem.
Le démontage de l'appareil pour une intervention interne est interdit. Les seuls éléments autorisés au démontage par l'utilisateur sont la la trappe d'accès au connecteur USB.
L'intégralité des pièces de rechange doit être fournie par le fabricant.
Liste des symboles d'avertissement
Attention ! : Chaque fois que ce symbole est présent sur l'appareil, se référer impérativement à l'avertissement de sécurité et la notice d'utilisation
Loading...
+ 22 hidden pages