Model VQ Ceiling and VQL In-Line fans are direct drive centrifugal exhausters design for ultra-quiet operation. Capacities up to 3868 CFM and up to 1 inch static pressure. Perfect for offices, conference rooms, bathrooms, hospital rooms - Anywhere quiet, high capacity ventilation is needed.
Sound-absorbing acoustic insulation completely lines
Quiet, built-in automatic backdraft damper located in duct connector.
Duct connectors on many models for easy installations.
housing on many models to further reduce sound levels.
Ceiling & Cabinet Exhausters
Heavy gauge galvanized steel housing.
Quite, low RPM motor ­permanently lubricated for continuous operation.
Impact-resistant, balanced centrifugal blower wheel ensures consistent performance.
8-way adjustable mounting brackets on many models permit installation flexibility.
Equipped with electrical terminal box and plug-in
disconnect inside housing Wiring plate allows unit to be wired from outside
housing Low RPM motors mounted on resilient mounts for
quiet, vibration-free operation Motors designed for continuous operation and are
permanently lubricated Acoustic insulation inside rugged, heavy gauge
galvanized steel housings (VQ50, VQ80, and some in-line models not insulated) May be installed in ceiling or wall
Balanced blower wheels for extremely low sound
levels Attractive, low profile grilles standard on VQ models
May be ducted right angle, straight through or as an
in-line blower (VQ50 and VQ80 right angle only) Quiet, built-in backdraft dampers (optional damper
kit for VQL2000 and VQL3500)
Specially designed resilient motor mounts help eliminate vibration.
DIMENSIONS
Fan Model A B C
VQ50 7.25 7.50 3.63 3.00 Round 5 VQ80 8.00 8.25 5.75 4.00 Round 7 VQ100, 150 VQL100, 150 VQ200, 250, 300 VQL200, 250, 300 VQ400, 500, 700 VQL400, 500, 700 VQ900, 1500 VQL900, 1500 VQL2000 14.68 38.00 14.63 7.75 x 33.75 89 VQL3500 16.75 45.75 16.75 9.75 x 41.375 144
Dimensions are shown in inches. Weights are shown in pounds.
12.25 12.25 11.75 6.00 Round 5
12.25 12.25 11.75 8.00 Round 5
12.25 21.50 11.75 4.50 x 18.50 34
18.00 22.00 18.00 8 x 12 64
Duct
Connector
Est. Ship
Low-profile grille complements any surroundings. Impact-resistant, high-strength polymer or white enameled steel, depending on model.
Acme Engineering & Manufacturing Corporation certifies that the models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings
Wt.
Program.
Consult your Acme representative for availability.
U.L.705 Listed
PERFORMANCE DATA
Fan
Model
VQ50 Right Angle 52 3.9 49 4.3 47 4.4 42 4.6 29 5.5 1870 48 0.7 VQ80 Right Angle 89 3.9 81 3.8 80 3.8 68 3.8 36 3.9 1280 48 0.5
VQ100
VQ150
VQ200
VQ250
VQ300
VQ400
VQ500
VQ700
VQ900
VQ1500
Discharge
Right Angle 136 0.5 115 0.8 109 0.9 93 1.3 80 1.8 65 2.3 44 3.0 12 3.2 640 87 1.1 Straight Through 138 0.7 117 0.9 112 1.0 94 1.3 80 1.8 67 2.2 46 2.8 13 3.0 650 87 1.1 Right Angle 181 1.3 161 1.4 157 1.5 141 2.2 132 2.6 124 3.1 114 3.6 94 4.1 62 4.6 710 100 1.3 Straight Through 179 1.4 163 1.6 160 1.6 149 2.0 142 2.5 133 3.0 122 3.3 105 3.6 73 3.9 23 42 750 100 1.3 Right Angle 231 1.6 214 1.8 210 1.7 196 2.3 186 2.9 177 3.5 165 4.1 144 4.9 113 5.3 51 5.3 740 127 1.8 Straight Through 224 1.5 210 1.8 207 2.0 197 2.3 187 2.7 179 3.4 167 4.0 144 4.5 99 5.1 41 5.2 760 127 1.8 Right Angle 272 2.1 261 2.3 259 2.2 250 2.9 242 3.3 233 3.9 218 4.4 201 4.8 165 5.5 99 5.8 830 166 2.1 Straight Through 269 2.3 261 2.6 259 2.7 253 3.0 248 3.3 239 3.7 224 4.2 203 4.7 171 5.4 101 5.6 860 166 2.1 Right Angle 312 2.8 309 2.9 308 2.9 303 3.3 296 3.5 287 3.9 273 4.3 254 4.7 219 5.1 125 5.6 905 212 2.6 Straight Through 319 2.6 314 2.9 313 3.0 306 3.4 299 3.6 288 3.9 274 4.4 251 4.7 219 5.0 120 5.5 940 212 2.6 Right Angle 480 2.0 442 2.4 434 2.3 388 2.8 344 3.3 299 3.8 229 4.5 182 4.8 114 5.4 33 5.6 735 146 1.4 Straight Through 467 2.3 428 2.6 416 2.6 378 3.0 335 3.5 291 4.0 237 5.1 170 5.5 85 5.7 8 5.9 755 146 1.4 Right Angle 538 3.0 520 3.1 514 3.3 491 3.6 463 4.0 434 4.4 389 5.0 339 5.7 282 6.2 186 6.7 810 232 2.2 Straight Through 539 2.9 517 3.1 512 3.2 481 3.4 451 3.8 418 4.2 367 4.8 319 5.9 247 6.3 137 6.4 865 232 2.2 Right Angle 722 4.5 704 4.6 701 4.7 667 4.8 640 5.0 607 5.2 571 5.6 534 6.2 453 7.1 333 7.2 960 313 2.9 Straight Through 708 5.2 691 5.0 687 5.0 658 5.7 628 5.8 597 6.1 560 6.4 515 7.4 444 7.1 312 7.6 985 313 2.9 Right Angle 918 3.8 905 4.0 901 4.1 877 4.0 842 4.2 793 4.3 725 4.4 636 4.9 536 4.5 390 5.3 650 306 3.0 Straight Through 909 3.8 892 3.4 885 3.4 850 3.5 807 3.6 756 3.7 695 3.9 568 4.2 440 4.3 282 4.4 650 306 3.0 Right Angle 1578 8.6 1526 8.4 1513 8.4 1438 8.1 1371 7.5 1285 7.0 1198 6.7 1103 6.2 1000 5.8 816 5.8 955 468 5.0 Straight Through 1590 8.5 1519 8.4 1502 8.4 1423 8.1 1340 7.9 1259 7.5 1176 7.2 1069 7.1 954 6.9 689 6.5 955 468 5.0
.000" .100" .125" .250" .375" .500" .625" .750" .875" 1.00"
CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone
Static Pressures
Nominal
RPM
Watts
AMPS
@60HZ
Performance ratings include the effects of inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard
301. Values shown are for Installation Type B: Free inlet hemispherical sone levels. Performance certified is for Installations Type B: Free inlet, Ducted outlet.
Ceiling & Cabinet Exhausters
PERFORMANCE DATA
Fan
Model
VQL100
VQL150
VQL200
VQL250
VQL300
VQL400
VQL500
VQL700
VQL900
VQL1500
Discharge
Right Angle 109 0.5 98 0.8 96 0.8 88 1.2 82 1.6 78 2.0 67 2.3 48 2.5 16 2.8 780 87 1.1 Straight Through 121 0.5 108 0.7 106 0.7 97 1.1 93 1.4 86 1.8 70 2.1 44 2.4 17 2.6 760 87 1.1 Right Angle 144 1.2 138 1.4 137 1.4 131 1.6 123 1.9 114 2.1 102 2.4 83 2.5 54 2.7 17 2.9 950 100 1.3 Straight Through 153 0.9 148 1.0 147 1.1 140 1.4 134 1.6 125 1.9 111 2.1 91 2.2 54 2.4 18 2.6 920 100 1.3 Right Angle 183 1.6 177 1.6 176 1.6 170 1.9 163 2.3 152 2.7 137 2.9 121 3.1 96 3.4 51 3.6 930 127 1.8 Straight Through 205 1.7 196 1.9 195 1.9 190 2.1 185 2.3 175 2.4 158 3.0 135 3.3 96 3.4 47 3.4 865 127 1.8 Right Angle 229 2.4 224 2.5 222 2.6 214 2.8 204 3.0 193 3.2 177 3.4 157 3.7 132 3.8 95 3.8 1115 166 2.1 Straight Through 248 2.0 245 2.3 245 2.3 241 2.6 235 2.8 224 3.2 208 3.4 183 3.6 141 3.9 84 3.8 1005 166 2.1 Right Angle 270 3.7 261 3.7 259 3.7 248 3.7 234 3.9 220 3.9 200 4.0 174 4.2 146 4.4 104 4.0 1285 212 2.6 Straight Through 300 2.9 294 3.0 293 3.1 285 3.3 274 3.4 259 3.5 243 3.6 214 3.7 168 4.0 113 3.9 1145 212 2.6 Right Angle 442 1.6 415 1.7 408 1.7 372 2.0 336 2.4 296 2.6 239 3.1 193 3.4 111 3.9 28 4.1 875 146 1.4 Straight Through 450 1.4 415 1.6 406 1.6 360 1.9 313 2.2 271 2.6 223 2.9 167 3.4 90 3.6 6 3.9 775 146 1.4 Right Angle 528 2.9 516 3.8 513 3.4 494 3.7 470 3.5 446 3.6 415 3.9 389 4.0 334 4.2 247 4.4 990 232 2.2 Straight Through 546 2.4 526 2.4 519 3.4 496 3.7 472 3.9 447 3.8 407 3.9 364 4.0 306 4.3 232 4.3 890 232 2.2 Right Angle 680 5.0 667 5.0 663 5.0 644 5.3 621 5.2 594 5.1 557 5.3 513 5.5 440 5.4 342 5.5 1205 313 2.9 Straight Through 704 3.6 686 3.8 681 3.7 656 3.9 631 4.0 604 4.2 575 4.3 533 4.4 480 4.7 412 5.0 1090 313 2.9 Right Angle 795 4.3 778 4.5 772 4.4 743 4.6 709 4.4 668 4.2 613 4.1 527 4.3 432 4.2 291 4.3 755 306 3.0 Straight Through 930 3.7 902 3.8 894 3.8 853 3.8 807 3.7 754 3.8 685 3.9 587 4.0 442 4.0 300 4.1 810 306 3.0 Right Angle 1160 7.9 1117 7.8 1106 7.9 1051 7.4 998 7.1 928 6.8 856 6.3 769 5.9 657 5.4 499 5.4 1020 468 5.0 Straight Through 1275 6.8 1228 6.8 1214 6.7 1152 6.5 1092 6.3 1029 6.0 958 6.0 871 6.0 764 6.0 631 6.1 1055 468 5.0
.000" .100" .125" .250" .375" .500" .625" .750" .875" 1.00"
CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone
Static Pressures
Nominal
RPM
Watts
AMPS
@60HZ
Performance ratings include the effects of backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculate per AMCA Standard 301. Values shown are for Installation Type D: Ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction. Performance ratings include the effects of 18 feet of round inlet duct, if needed, a rectangular to round duct transition in the airstream. Performance certified is for Installation Type D: Ducted inlet, Ducted outlet.
PERFORMANCE DATA
Fan
Model
VQL2000
VQL3500
Discharge
Right Angle 2070 11.1 1931 10.3 1898 10.1 1769 9.7 1609 9.4 1424 9.2 1314 8.5 795 7.0 288 6.7 1020 635 5.8 Straight Through 1891 10.3 1803 9.8 1791 9.4 1657 9.0 1508 8.6 1347 9.1 1165 8.9 808 7.0 284 6.7 965 590 5.8 Right Angle 3868 14.6 3714 14.2 3696 14.2 3537 13.3 3356 12.8 3168 12.5 2951 11.6 2671 11.4 2384 11.4 2005 13.4 1110 1205 5.4 Straight Through 3605 15.3 3498 14.8 3452 14.5 3278 14.1 3073 13.1 2893 12.8 2679 12.1 2429 11.8 2093 11.9 1693 10.8 1105 1204 5.4
.000" .100" .125" .250" .375" .500" .625" .750" .875" 1.00"
CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone
Static Pressures
Nominal
RPM
Watts
AMPS
@60HZ
Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown for Installation Type D: Ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction. Performance certified is for Installation Type D: Ducted inlet, Ducted outlet.