Acme Engineering PNU100 User Manual

Belt Drive Centrifugal Roof/Wall Exhauster
Models PNURF and PNURG Restaurant Exhausters
Models PNURF and PNURG (restaurant exhauster) are belt drive upblast centrifugal exhausters. Capacities up to 33,374 CFM and up to 3 inches static pressure. Models PNUHP and PNUXP are high pressure exhausters for applications up to 5 inches static pressure. The PNURF is a clean air ventilator designed for high velocity vertical discharge. Model PNURG is ideally suited for removal of grease laden exhaust found in restaurant and commercial kitchen applications. Other applications include a wide range of commercial, industrial, and institutional facilities such as schools, hospitals, prisons, and assembly areas.
Centrifugal Exhausters
DIMENSIONS
Fan
Model
New Former RF RG
PNU080 PNUXP080 24.00 26.35 33.66 22.09 19.5 x 19.5 AR18 C22.5 CR22.5 PNU100 PNUHP100 24.00 26.35 33.66 22.09 19.5 x 19.5 AR18 C22.5 CR22.5 PNU120 PNU120 24.00 27.37 33.50 22.13 19.5 x 19.5 AR18 C22.5 CR22.5 PNU135 PNU135 24.00 27.37 33.50 22.13 19.5 x 19.5 AR18 C22.5 CR22.5 PNU150 PNU150 28.00 25.92 38.00 22.46 23.5 x 23.5 AR22 C26.5 CR26.5 PNU155 PNUXP165 28.00 29.59 38.00 24.14 23.5 x 23.5 AR22 C26.5 CR26.5 PNU160 PNUHP165 28.00 25.59 38.00 24.14 23.5 x 23.5 AR22 C26.5 CR26.5 PNU165 PNU165 28.00 25.92 38.00 22.46 23.5 x 23.5 AR22 C26.5 CR26.5 PNU185 PNU185 28.00 31.56 39.75 28.73 23.5 x 23.5 AR22 C26.5 CR26.5 PNU200 PNU200 28.00 31.56 39.75 28.73 23.5 x 23.5 AR22 C26.5 CR26.5 PNU235 PNUXP245 34.00 35.01 44.67 31.42 29.5 x 29.5 AR28 C32.5 CR32.5 PNU240 PNUHP245 34.00 35.01 44.67 31.42 29.5 x 29.5 AR28 C32.5 CR32.5 PNU245 PNU245 34.00 38.76 44.75 31.50 29.5 x 29.5 AR28 C32.5 CR32.5 PNU290 PNUXP300 40.00 40.41 55.29 34.15 35.5 x 35.5 ARH34 C38.5 CR38.5 PNU295 PNUHP300 40.00 40.41 55.29 34.15 35.5 x 35.5 ARH34 C38.5 CR38.5 PNU300 PNU300 40.00 42.50 55.38 34.25 35.5 x 35.5 ARH34 C38.5 CR38.5 PNU355 PNUXP365 46.00 44.10 65.75 41.00 41.5 x 41.5 ARH40 C44.5 CR44.5 PNU360 PNUHP365 46.00 44.10 65.75 41.00 41.5 x 41.5 ARH40 C44.5 CR44.5 PNU365 PNU365 46.00 46.00 66.00 41.25 41.5 x 41.5 ARH40 C44.5 CR44.5 PNU425 PNU425 60.00 53.50 79.75 49.75 55.5 x 55.5 ARH54 C58.5 CR58.5 PNU490 PNU490 60.00 58.00 79.75 52.10 55.5 x 55.5 ARH54 C58.5 CR58.5
Dimensions are shown in inches. *Recommended maximum. ‡ Please contact your local representative for correct rated sizing for hurricane
ABCD
Roof
Opening*‡
Damper
Model
Roof Curb‡
Construction Features
Housing
Windband constructed of heavy gauge aluminum with rolled
bead for strength Sealed windband perimeter to prevent leakage
Wheel and drive assembly supported by rugged galvanized
steel frame Quick release latches allow easy removal of motor
compartment cover without special tools Aluminum curb cap (except smoke exhaust fans)
Centrifugal Wheel
Aluminum construction backward curved blade (steel wheel
for smoke exhaust fans) Non-overloading design for safe operation
Wheel optimally matched with die-formed orifice
Precision balanced for smooth vibration free operation
Bearings
Permanently lubricated in an Acme D.S. pillow block housing
Bearings are resiliently mounted in neoprene rings
Rated at L50life of 200,000 hours
5 year limited warranty on Acme D.S. pillow block bearings
Drive Assembly
Cast iron drives sized for 150% of drive horsepower
Static free, oil and heat resistant belts
Motors
Continuous duty motors located outside the airstream
Large breather tube directs outside air into the motor compartment resulting in maximum life
Motor compartment cooled by fins located on top of impeller
Options/Accessories
Roof Curbs
Dampers
Coatings
SE Option U.L. Listed "Power Ventilator for Smoke Control Systems"
Wall Bracket (PNU080-245)
Grease Trough
Curb Hinge
Pillow block bearings with 2 year warranty
Acme Engineering & Manufacturing Corporation certifies that the models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Model PNURF is Listed for Electrical (UL/C-UL 705) File No. E39982. Model PNURG is Listed for (UL 762) File No. MH11542.
CSA Certified
Consult your Acme representative for availability.
Page 20
PNU080 (PNUXP080)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
RPM
1324
1633
1673
2110
2130
2333
2598
2833
2840
2877
3293
3378
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
330 271 211 117
0.05 5.0 0.06 4.7 0.06 4.7 0.06 4.9 407 360 310 262 190
0.09 7.0 0.10 6.7 0.11 6.4 0.11 6.1 0.12 6.7 417 371 322 277 211
0.10 7.3 0.11 7.1 0.12 6.7 0.12 6.5 0.12 7.0 526 488 452 413 377 339 289 225
0.20 11.4 0.21 11.2 0.22 10.7 0.23 10.3 0.24 10.2 0.25 10.5 0.25 10.8 0.25 11.1 531 493 458 419 384 347 299 236 155
0.21 11.5 0.22 11.4 0.23 10.9 0.24 10.5 0.25 10.4 0.25 10.6 0.26 10.9 0.26 11.3 0.24 11.7 582 546 516 480 445 414 380 338 281 224
0.27 13.2 0.28 13.1 0.30 12.5 0.31 12.2 0.32 11.9 0.33 11.9 0.33 12.2 0.34 12.5 0.34 12.9 0.33 13.3 648 614 588 558 526 495 467 439 403 360
0.37 15.5 0.39 15.5 0.40 14.9 0.42 14.6 0.43 14.0 0.44 13.6 0.45 14.0 0.46 14.3 0.46 14.7 0.47 15.2 707 674 650 625 596 567 538 512 487 456
0.49 17.7 0.50 17.6 0.52 17.0 0.53 16.8 0.54 16.0 0.56 15.3 0.57 15.7 0.58 16.0 0.59 16.3 0.60 17.0 709 675 652 627 598 569 540 514 489 459
0.49 17.7 0.50 17.7 0.52 17.1 0.54 16.9 0.55 16.1 0.56 15.4 0.57 15.7 0.58 16.0 0.59 16.4 0.60 17.0 718 685 662 637 609 580 552 526 501 473
0.51 18.1 0.52 18.1 0.54 17.4 0.56 17.2 0.57 16.4 0.58 15.7 0.59 16.0 0.61 16.3 0.62 16.7 0.62 17.0 822 791 770 750 727 703 678 653 628 605
0.76 23 0.77 23 0.79 22 0.82 22 0.83 20 0.85 19.2 0.86 19.4 0.88 19.7 0.89 20 0.91 20 843 813 792 772 751 727 703 678 654 631
0.82 24 0.83 24 0.85 23 0.88 23 0.90 21 0.91 20 0.93 20 0.94 21 0.96 21 0.97 21
Fan Model HP RPM Range
PNU080E1 1/4 1324 - 1673 84 120 PNU080E2 1/4 1633 - 2110 84 120 PNU080E3 1/4 2130 - 2598 84 120 PNU080F 1/3 2333 - 2877 87 123 PNU080G 1/2 2833 - 3293 94 130 PNU080H 3/4 2840 - 3378 101 137
Est. Unit Wt. Est. Ship Wt.
lbs. lbs.
Centrifugal Exhausters
CFM and Sones vs. Static Pressure
RPM
2598
2833
2840
2877
3293
3378
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable.
2.500" 2.750" 3.000" 3.250" 3.500" 3.750" 4.000" 4.250" 4.500" 4.750" 5.000"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
309 258 177
0.47 15.4 0.46 15.8 0.44 16.2 423 379 332 285 224
0.60 17.1 0.61 17.4 0.61 17.8 0.60 18.1 0.58 18.5 425 382 335 288 232
0.61 17.1 0.61 17.5 0.61 17.8 0.60 18.2 0.59 18.5 439 401 354 308 262
0.63 17.4 0.63 17.7 0.64 18.1 0.63 18.4 0.62 19.1 583 562 535 506 475 435 394 354 313 251
0.92 21 0.93 21 0.94 21 0.94 22 0.95 22 0.95 22 0.95 23 0.94 23 0.93 23 0.91 24 610 588 566 538 510 477 437 398 358 319 257
0.98 22 1.00 22 1.01 22 1.01 22 1.02 23 1.03 23 1.03 23 1.03 24 1.02 24 1.01 25 0.98 25
Page 21
RPM
942
1211
1225
1531
1561
1633
Centrifugal Exhausters
1922
1983
2128
2288
2436
2798
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
500 359
0.02 3.9 0.03 4.3 642 543 404
0.05 5.9 0.06 5.6 0.07 7.2 650 552 417
0.05 6.0 0.06 5.7 0.07 7.3 812 738 651 538 383
0.09 9.0 0.11 8.7 0.12 9.0 0.13 10.8 0.13 11.4 828 755 671 564 422
0.10 9.3 0.11 9.1 0.13 9.2 0.14 11.0 0.14 11.8 866 797 717 623 496
0.11 10.3 0.13 10.1 0.14 9.9 0.16 11.9 0.16 13.0
1020 960 898 828 746 645 528
0.18 16.9 0.20 16.5 0.22 16.1 0.24 16.7 0.25 19.2 0.26 21 0.26 21
1052 995 935 867 791 700 590
0.20 17.7 0.22 17.5 0.24 17.1 0.26 17.3 0.27 19.6 0.28 21 0.29 22
1129 1075 1022 959 894 819 727 623
0.25 18.9 0.27 19.1 0.29 18.3 0.31 18.3 0.33 19.4 0.34 22 0.35 23 0.36 24
1214 1164 1114 1059 1000 935 865 776 679 563
0.31 20 0.33 21 0.35 19.7 0.37 19.2 0.40 19.6 0.41 22 0.43 23 0.44 24 0.44 25 0.44 25
1292 1246 1199 1149 1094 1039 974 907 821 730
0.37 22 0.39 22 0.42 21 0.44 20 0.47 21 0.49 21 0.50 23 0.52 25 0.53 26 0.53 27
1484 1444 1403 1362 1318 1270 1222 1171 1114 1057
0.56 25 0.59 27 0.62 24 0.64 24 0.67 23 0.70 24 0.72 24 0.75 26 0.77 27 0.78 28
PNU100 (PNUHP100)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
Fan
Model
PNU100E1 1/4 942 - 1211 84 120 PNU100E2 1/4 1225 - 1561 84 120 PNU100E3 1/4 1531 - 1922 84 120 PNU100F 1/3 1633 - 2128 87 123 PNU100G 1/2 1983 - 2436 94 130 PNU100H 3/4 2288 - 2798 101 137
HP
RPM
Range
Est. Unit
Est. Ship Wt. lbs. lbs.
Wt.
CFM and Sones vs. Static Pressure
RPM
2436
2798
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable.
2.500" 2.750" 3.000" 3.250" 3.500" 3.750" 4.000" 4.250" 4.500" 4.750" 5.000"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
626
0.53 27 984 909 828 742
0.80 29 0.81 30 0.81 31 0.81 31
Page 22
PNU120 (PNU120)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
RPM
710
908
1033
1167
1321
1415
1544
1615
1787
1878
2059
2305
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
739
0.02 4.4 945 638
0.03 6.4 0.05 6.0
1075 815
0.05 8.0 0.07 7.6
1215 987
0.07 10.4 0.10 10.2
1375 1167 956
0.11 10.6 0.13 9.6 0.15 8.9
1473 1275 1089
0.13 12.0 0.16 11.0 0.18 10.3
1607 1420 1263 1062
0.17 12.5 0.20 12.4 0.23 12.3 0.24 11.7
1681 1499 1354 1166 939
0.19 13.6 0.22 13.4 0.26 13.4 0.28 12.9 0.28 12.6
1860 1689 1557 1408 1233
0.26 15.4 0.29 14.8 0.33 14.4 0.36 14.8 0.38 16.4
1955 1792 1662 1529 1366 1197
0.30 16.7 0.34 16.1 0.38 15.7 0.41 16.0 0.43 17.3 0.45 19.1
2144 1995 1868 1755 1620 1468
0.40 17.6 0.44 17.2 0.48 16.9 0.52 16.8 0.56 17.2 0.57 17.0
2400 2267 2143 2042 1940 1815 1680 1543 1372
0.56 21 0.60 23 0.65 21 0.70 21 0.74 20 0.78 19.1 0.80 19.1 0.82 22 0.82 22
Fan
Model
PNU120E1 1/4 710 - 849 84 120
PNU120E2 1/4 850 - 1033 84 120
PNU120E3 1/4 908 - 1099 84 120 PNU120E4 1/4 1100 - 1321 84 120 PNU120E5 1/4 1167 - 1369 84 120 PNU120E6 1/4 1370 - 1615 84 120 PNU120F1 1/3 1415 - 1600 87 123 PNU120F2 1/3 1601 - 1787 87 123 PNU120G1 1/2 1544 - 1804 94 130 PNU120G2 1/2 1805 - 2059 94 130 PNU120H1 3/4 1878 - 2082 101 137 PNU120H2 3/4 2083 - 2305 101 137
HP
RPM
Range
Est. Unit
Est. Ship Wt. lbs. lbs.
Wt.
Centrifugal Exhausters
PNU135 (PNU135)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
RPM
795
994
1122
1213
1346
1400
1551
1785
2055
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
1143 708
0.04 8.2 0.06 6.8 1429 1087
0.08 9.4 0.09 8.2 1613 1308 997
0.10 11.0 0.13 10.2 0.14 8.9 1743 1464 1184
0.13 12.6 0.15 12.1 0.18 10.2 1934 1685 1432 1161
0.17 14.1 0.20 13.6 0.23 12.5 0.24 11.3 2012 1774 1527 1275
0.19 14.9 0.22 14.5 0.25 13.7 0.27 12.4 2229 2016 1788 1577 1333
0.26 16.3 0.29 16.2 0.32 15.4 0.35 13.7 0.37 13.2 2565 2381 2187 1993 1810 1599 1320
0.39 19.6 0.43 17.6 0.46 18.6 0.49 17.6 0.53 16.8 0.55 16.1 0.55 14.7 2953 2793 2630 2457 2291 2132 1957 1772 1507
0.58 25 0.63 21 0.67 23 0.71 22 0.75 21 0.79 19.5 0.82 18.9 0.83 18.3 0.83 18.3
Fan
Model
PNU135E1 1/4 795 - 999 84 120 PNU135E2 1/4 1000 - 1099 84 120 PNU135E3 1/4 1000 - 1199 84 120 PNU135E4 1/4 1200 - 1400 84 120 PNU135F1 1/3 1122 - 1300 87 123 PNU135F2 1/3 1275 - 1551 87 123 PNU135G1 1/2 1346 - 1499 94 130 PNU135G2 1/2 1500 - 1785 94 130 PNU135H1 3/4 1551 - 1749 101 137 PNU135H2 3/4 1750 - 2055 101 137
HP
RPM
Range
Est. Unit
Est. Ship
Wt.
lbs. lbs.
Wt.
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable.
Page 23
RPM
1034
1129
1250
1286
1346
Centrifugal Exhausters
1432
1615
1632
1795
2064
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250" 2.500" 3.000"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
1763 1420 918
833
0.09 8.8 0.11 7.2 0.12 7.2 1792 1456 982
847
0.09 9.2 0.12 7.5 0.13 7.5 2188 1922 1607 1187
0.17 10.7 0.20 10.4 0.23 10.9 0.23 10.9 2389 2151 1874 1547 344
0.22 13.2 0.26 13.0 0.29 14.4 0.31 13.7 0.16 13.7 2645 2431 2192 1921 1607
0.30 15.1 0.34 14.3 0.37 14.1 0.41 12.7 0.42 12.6 2721 2514 2283 2024 1728 793
0.33 15.8 0.37 15.0 0.40 14.8 0.44 13.5 0.46 12.9 0.32 12.9 2848 2650 2433 2194 1925 1583
0.38 15.7 0.42 14.0 0.46 13.8 0.49 13.1 0.52 12.9 0.52 12.9 3030 2844 2645 2431 2186 1912 1540
0.45 17.7 0.50 15.8 0.54 16.0 0.57 14.7 0.61 15.3 0.63 14.7 0.62 14.7 3417 3252 3086 2896 2701 2484 2248 1974 803
0.65 21 0.70 19.6 0.75 18.5 0.79 19.4 0.83 18.3 0.88 19.1 0.90 17.9 0.91 17.9 0.57 17.9 3453 3290 3126 2939 2748 2533 2304 2050 1097
0.67 21 0.72 20 0.78 18.9 0.82 19.7 0.86 18.7 0.90 19.4 0.93 18.4 0.94 18.4 0.69 18.4 3798 3649 3501 3340 3169 2991 2795 2594 2364 2075 715
0.89 23 0.95 23 1.01 22 1.06 22 1.10 22 1.15 21 1.19 19.8 1.23 19.1 1.25 18.3 1.23 18.3 0.70 18.3 4367 4238 4109 3979 3835 3687 3538 3373 3203 3033 2834 2357
1.36 30 1.43 31 1.49 28 1.56 27 1.61 27 1.66 27 1.71 26 1.76 26 1.82 25 1.87 24 1.89 23 1.87 23
PNU150 (PNU150)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
Fan
Model
PNU150E 1/4 833 - 1129 99 176 PNU150F 1/3 833 - 1250 102 179 PNU150G 1/2 1034 - 1432 109 186 PNU150H 3/4 1286 - 1632 116 193 PNU150J 1 1346 - 1795 128 205 PNU150K 1 1/2 1615 - 2064 139 216
HP
RPM
Range
Est. Unit
Est. Ship Wt. lbs. lbs.
Wt.
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable.
Page 24
PNU155 (PNUXP165)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
RPM
950
1039
1188
1330
1355
1524
1583
1663
1707
1943
2197
2217
2419
2769
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
527 453 365
0.04 5.3 0.06 4.8 0.06 5.1 576 508 434 349
0.05 6.0 0.07 5.1 0.08 4.9 0.09 5.5 659 600 540 466 394
0.08 7.3 0.10 6.5 0.12 6.2 0.13 6.3 0.13 6.8 737 685 631 575 505 442
0.12 8.6 0.14 7.9 0.15 7.5 0.17 7.5 0.18 7.6 0.18 8.0 751 700 647 594 525 462
0.12 8.9 0.14 7.7 0.16 7.7 0.18 7.7 0.19 7.9 0.19 8.3 845 799 753 706 656 594 538
0.17 10.9 0.20 10.1 0.22 9.6 0.24 9.3 0.25 9.3 0.27 9.5 0.27 9.8 878 833 789 744 699 640 584 530
0.19 11.6 0.22 10.8 0.24 10.3 0.26 10.1 0.28 10.3 0.29 10.4 0.30 10.5 0.30 10.8 922 880 838 795 752 702 645 594 525
0.22 12.5 0.25 11.8 0.28 11.2 0.30 10.9 0.32 10.8 0.33 10.8 0.35 11.0 0.35 11.3 0.35 11.7 946 905 864 823 781 735 680 628 579
0.24 13.1 0.27 12.4 0.30 11.8 0.32 11.3 0.34 11.2 0.36 11.2 0.37 11.3 0.38 11.6 0.38 12.1
1077 1041 1005 969 932 896 859 812 763 718
0.36 16.1 0.39 15.5 0.42 14.8 0.45 14.4 0.47 14.0 0.50 13.1 0.52 13.9 0.54 13.9 0.55 14.0 0.56 14.2
1218 1186 1154 1122 1090 1058 1026 993 959 916
0.52 18.9 0.55 18.0 0.59 17.1 0.62 16.4 0.65 16.6 0.68 16.7 0.71 16.8 0.73 16.8 0.76 16.8 0.78 16.8
1229 1198 1166 1134 1103 1071 1038 1006 974 931
0.53 19.1 0.57 18.6 0.60 18.1 0.64 17.7 0.67 17.4 0.70 17.2 0.72 17.1 0.75 17.1 0.78 17.1 0.79 17.1
1341 1312 1283 1254 1225 1196 1167 1137 1108 1078
0.69 22 0.73 21 0.77 21 0.80 21 0.84 21 0.88 21 0.91 21 0.94 21 0.96 21 0.99 21
1535 1510 1485 1459 1434 1409 1383 1358 1332 1306
1.04 26 1.08 26 1.12 25 1.17 25 1.21 25 1.25 24 1.30 24 1.33 24 1.36 29 1.40 24
Fan
Model
PNU155E1 1/4 950 - 1355 99 176 PNU155E2 1/4 1039 - 1524 99 176 PNU155F 1/3 1188 - 1707 102 179 PNU155G 1/2 1330 - 1943 109 186 PNU155H 3/4 1583 - 2197 116 193 PNU155J 1 1663 - 2419 128 205 PNU155K 1 1/2 2217 - 2769 139 216
HP
RPM
Range
Est. Unit
Wt. lbs. lbs.
Est. Ship
Wt.
CFM and Sones vs. Static Pressure
RPM
1943
2197
2217
2419
2769
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable.
2.500" 2.750" 3.000" 3.250" 3.500" 3.750" 4.000" 4.250" 4.500" 4.750" 5.000"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
675
0.56 14.6 873 832 793 755 688
0.79 16.8 0.80 16.8 0.81 17.1 0.81 17.3 0.80 17.7 889 847 809 770 732
0.81 17.1 0.83 17.1 0.83 17.3 0.83 17.5 0.83 17.7
1044 1005 966 927 892 857 822 754
1.02 21 1.04 21 1.06 21 1.07 21 1.07 21 1.08 21 1.08 20 1.07 20
1280 1255 1229 1198 1164 1130 1096 1063 1032 1001 971
1.43 24 1.46 24 1.50 24 1.52 24 1.55 24 1.57 24 1.59 24 1.61 24 1.61 24 1.61 24 1.61 24
Page 25
RPM
729
857
886
1012
1042
1175
1218
Centrifugal Exhausters
1267
1289
1480
1508
1694
1865
2135
.000" .250" .500" .750" 1.000" 1.250" 1.500" 1.750" 2.000" 2.250"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
1071 855
0.04 5.0 0.06 5.0 1259 1083 818
0.06 6.5 0.09 6.3 0.11 5.4 1301 1134 897
0.07 6.9 0.10 6.6 0.12 6.5 1487 1346 1170 897
0.10 8.3 0.14 6.8 0.16 6.5 0.18 6.7 1531 1394 1230 981
0.12 8.9 0.15 7.3 0.18 6.8 0.19 7.1 1726 1605 1468 1297 1054
0.16 10.5 0.20 9.3 0.24 8.6 0.26 8.6 0.28 8.6 1789 1673 1543 1388 1173 718
0.18 11.6 0.22 10.0 0.26 9.1 0.29 9.3 0.30 9.4 0.28 9.1 1862 1749 1627 1490 1304 997
0.21 11.1 0.24 10.5 0.28 9.6 0.32 9.6 0.34 10.0 0.34 9.9 1894 1783 1665 1530 1352 1091
0.22 11.4 0.26 10.8 0.30 10.0 0.33 9.9 0.36 10.3 0.36 10.2 2175 2078 1982 1869 1751 1596 1405 1097
0.33 14.3 0.37 13.0 0.42 12.8 0.46 12.7 0.50 12.8 0.53 13.1 0.55 12.9 0.54 13.0 2216 2121 2027 1917 1802 1656 1481 1218
0.35 15.1 0.39 13.5 0.44 13.2 0.48 13.1 0.53 13.1 0.56 13.7 0.58 13.7 0.58 13.7 2489 2405 2321 2235 2132 2029 1903 1764 1581 1313
0.49 17.5 0.54 17.6 0.60 16.9 0.65 16.4 0.70 16.0 0.74 15.8 0.78 16.5 0.81 16.8 0.82 16.7 0.81 16.9 2740 2664 2588 2511 2426 2333 2240 2130 2003 1863
0.66 21 0.72 21 0.77 19.6 0.83 19.5 0.88 18.6 0.94 18.9 0.99 18.6 1.03 19.3 1.07 19.8 1.10 19.9 3137 3071 3004 2937 2870 2797 2716 2634 2553 2457
0.99 26 1.05 26 1.12 26 1.18 25 1.25 24 1.31 24 1.37 24 1.43 24 1.49 24 1.54 24
PNU160 (PNUHP165)
PERFORMANCE DATA
CFM and Sones vs. Static Pressure
Centrifugal Exhausters
Est. Unit
Fan
Model
PNU160E1 1/4 729 - 1012 129 169 PNU160E2 1/4 857 - 1175 132 172 PNU160F 1/3 886 - 1289 131 180 PNU160G 1/2 1042 - 1480 188 209 PNU160H 3/4 1218 - 1694 154 194 PNU160J 1 1267 - 1865 161 201 PNU160K 1 1/2 1508 - 2135 172 212
HP
RPM
Range
Est. Ship Wt. lbs. lbs.
Wt.
CFM and Sones vs. Static Pressure
RPM
1865
2135
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable.
2.500" 2.750" 3.000" 3.250" 3.500" 3.750" 4.000" 4.250" 4.500" 4.750" 5.000"
BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone
1687 1418
1.10 19.7 1.08 19.9 2347 2236 2101 1947 1732 1414
1.58 25 1.62 25 1.64 25 1.65 25 1.63 25 1.56 25
Page 26