Acme Engineering PL163 User Manual

Belt Drive Centrifugal Roof Exhauster
Model PL
Model PL belt drive fans are downblast centrifugal power roof ventilators designed for exhausting clean air. Capacities up to 31,810 CFM and up to 1 inch static pressure. The PL is built to be a low profile exhauster. PL exhausters are suitable for all types of commercial and institutional buildings such as schools, hospitals, office buildings and retail stores.
Construction Features
Hoods and base constructed of heavy gauge aluminum
and supported by steel frame Bolted-on hood provides easy access to motor and drive
compartment for servicing Rugged structural frame transmits entire weight of motor,
impeller, drive assembly and hood directly to roof curb Steel fasteners are zinc dichromate plated
Heavy gauge galvanized wire birdscreen
Full perimeter storm band and wide hood overhang
provide extra protection from driving rain and snow Full 360° perimeter hood outlet area for quiet, efficient
performance
Airfoil Centrifugal Wheel
Aluminum construction with backward curved hollow airfoil
blades Non-overloading design for safe operation
Precision balanced for smooth vibration free operation
Bearings
Permanently lubricated in an Acme D.S. pillow block
housing Bearings are resiliently mounted in neoprene rings
Rated at L50life of 200,000 hours
5 year limited warranty on Acme D.S. pillow block
bearings
Pillow block bearings standard on PL365-543
Centrifugal Exhausters
DIMENSIONS
Fan
Model
PL135 24.00 16.29 37.48 5.10 19.5 x 19.5 AR18 C22.5 PL145 24.00 16.29 37.48 5.10 19.5 x 19.5 AR18 C22.5 PL163 28.00 18.83 39.06 5.85 23.5 x 23.5 AR22 C26.5 PL171 28.00 18.82 39.06 5.85 23.5 x 23.5 AR22 C26.5 PL200 28.00 16.25 39.06 3.50 23.5 x 23.5 AR22 C26.5 PL223 28.00 16.25 39.06 3.50 23.5 x 23.5 AR22 C26.5 PL245 34.00 17.95 44.00 3.73 29.5 x 29.5 AR28 C32.5 PL270 34.00 17.95 44.00 3.73 29.5 x 29.5 AR28 C32.5 PL300 40.00 21.00 53.00 5.50 35.5 x 35.5 AR34 C38.5 PL330 40.00 21.00 53.00 5.50 35.5 x 35.5 AR34 C38.5 PL365 46.00 28.00 64.00 6.50 41.5 x 41.5 AR40 C44.5 PL403 46.00 28.00 64.00 6.50 41.5 x 41.5 AR40 C44.5 PL490 60.00 34.50 78.00 8.50 55.5 x 55.5 AR54 C58.5 PL543 60.00 34.50 78.00 8.50 55.5 x 55.5 AR54 C58.5
Dimensions are shown in inches. *Recommended maximum.
ABCE
Acme Engineering & Manufacturing Corporation certifies that the models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Roof
Opening*
Damper
Model
Curb
Model
Drive Assembly
Cast iron drives sized for 150% of drive horsepower
Static free, oil and heat resistant belts
Motors
Continuous duty motors mounted on slide rails to maintain correct belt tension
Factory wired to junction box
Options/Accessories
Roof Curbs
Dampers
Coatings
Curb Hinge
Louvered Hood (PLZ)
U.L. 705 Listed CSA Certified
Consult your Acme representative for availability.
Page 41
PERFORMANCE DATA
Fan
Model
PL135E1
PL135E2
PL135E3
PL135E4
PL135E5
PL135F
PL145E1
PL145E2
PL145E3
PL145F
PL163E1
Centrifugal Exhausters
PL163E2
PL163F
PL163G
PL171E1
PL171E2
PL171F
PL171G
PL200E1
PL200E2
PL200F
PL200G
PL223E1
PL223E2
PL223F
PL223G
PL245E
PL245F
PL245G
PL245H
PL270E
PL270F
PL270G
PL270H
Performance certified is for installation type A: Free inlet, Free Outlet. Performance ratings do not include the effects of appurtenance (accessories). The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer ’s recommendations. It is therefore not detrimental to the motor and is economically desirable. Power rating (BHP) does not include transmission losses.
Sones
RPM
@
7.3
14.1
11.3
14.4
9.9
13.9
9.5
11.4
8.6
10.8
6.8
9.8
7.3
10.8
6.9
9.8
HP
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
635
1/4
878
1/4
1115
1/4
1225
1/4
1380
1/4
1775
1/3
1230
1/4
1285
1/4
1500
1/4
1850
1/3
1545
1/4
1740
1/4
1965
1/3
2195
1/2
1665
1/4
1915
1/4
2030
1/3
2235
1/2
1790
1/4
1900
1/4
2265
1/3
2545
1/2
1910
1/4
2090
1/4
2325
1/3
2790
1/2
2500
1/4
3005
1/3
3170
1/2
3705
3/4
2815
1/4
3170
1/3
3485
1/2
4183
3/4
1/8” SP
474 5.4 712 950 657
987 1320 835 9.9
1228 1640
917 10.8 1376 1840 1032
1548 2070 1327 16.0 1720 2299
752 9.6 1075 1760
786 1180 1930
918 1376 2250
1130 17.1 1522 2490
658
988 2325
741 11.3 1110 2610
835 1229 2890
934 16.6 1425 3350
609
896 2450
700 9.8 1029 2815
742 1110 3035
817 14.3 1247 3410
499
727 2605
530 9.3
820 2940
632
906 3245
710 16.4 1049 3584
393
590 2870
430 8.0
674 3280
478
749 3645
574 12.1
860 4183
368
577 3920
442 9.3
638 4335
466
713 4845
545 14.8
831 5650
327
491 4225
368 8.0
532 4580
405
606 5215
486 12.7
688 5922
.000" .125" .250" .375" .500" .625" .750" 1.000" Est.
.01
660
.02 .01 .05 .03 .10 .04 .13 .06 .19 .12 .26 .04 .11 .04 .14 .07 .28 .13 .31 .04 .15 .06 .21 .09 .29 .13 .45 .05 .15 .06 .22 .08 .28 .11 .40 .05 .16 .06 .23 .10 .31 .15 .47 .04 .15 .06 .22 .08 .30 .13 .45 .06 .21 .10 .29 .11 .40 .18 .64 .06 .21 .09 .27 .12 .40 .21 .59
545
1100
865
1460
990 1675 1165 1925 1605 2140
970 1590 1040 1770 1300 2120 1690 2370 1185 2100 1430 2420 1695 2720 1960 3210 1280 2185 1580 2585 1715 2825 1945 3220 1370 2290 1500 2660 1910 2980 2230 3380 1345 2490 1585 2940 1865 3335 2400 3910 1805 3450 2410 3900 2600 4455 3200 5300 2045 3695 2490 4090 2855 4785 3645 5540
.02 .02 .06 .04 .11 .05 .14 .06 .20 .13 .28 .04 .12 .05 .15 .08 .24 .14 .32 .05 .17 .07 .23 .10 .31 .14 .47 .06 .17 .07 .25 .10 .31 .13 .43 .06 .17 .07 .24 .11 .32 .16 .49 .05 .16 .07 .23 .09 .31 .15 .47 .07 .23 .11 .31 .13 .43 .20 .67 .08 .24 .11 .30 .14 .43 .23 .62
900 575
1295
755
1525
975 1780 1450 2040
500 1395
650 1610 1040 1980 1510 2250
540 1850
950 2200 1370 2530 1685 3045
470 1935 1150 2360 1345 2610 1650 3025
815 2025 1100 2410 1610 2750 1960 3205
2128
2635 1250 3055 2025 3660
3020 1820 3510 2060 4095 2770 4980
3210
835 3635 2130 4370 3151 5160
.06 .04 .11 .05 .16 .07 .23 .14 .29 .04 .13 .05 .17 .08 .25 .15 .33 .05 .18 .08 .24 .11 .32 .15 .49 .04 .18 .06 .27 .11 .33 .14 .45 .06 .18 .08 .25 .12 .33 .17 .51
.17
.25 .09 .34 .16 .50
.25 .12 .33 .14 .44 .21 .69
.26 .06 .32 .15 .46 .25 .65
CFM and BHP vs. Static Pressure
585
.06
1135
250
1385
725 1655 1310 1920
1150
1410
600 1830 1290 2120
1560
1960
865 2325 1355 2875
1590
2130
570 2410 1190 2845
1750
2170 1225 2540 1675 3030
1585
2280
2775 1375 3425
2580
3130
3750 2265 4680
2535
3125
3980 2437 4820
.12 .04 .17 .07 .24 .15 .30
.13
.17 .07 .27 .15 .35
.19
.26 .10 .34 .16 .51
.18
.28 .08 .34 .12 .48
.19
.27 .13 .35 .18 .52
.17
.26
.35 .16 .50
.26
.35
.47 .22 .72
.26
.33
.48 .25 .68
930
1230
1535 1140 1805
760
1155
1660
990
1970
1145
1690
2100
800
2695
1030
1815
2155
130
2660
1410
1930
2325 1260 2880
1740
2440
3170
1945
2710
3415
4400
1855
3505
4470
.13
.18
.25 .16 .31
.12
.17
.28 .14 .36
.17
.26
.35 .13 .53
.16
.28
.35 .07 .49
.19
.28
.36 .17 .54
.25
.36
.53
.25
.36
.49
.74
.29
.49
.71
575
1045
1395
920
1700
745
1455
440
1810
385
1305
1855
2505
1370
1835
2435
1630
2110
2715
1885
2880
2010
3045
4110
2625
4050
.11
.18
.25 .16 .33
.15
.28 .11 .37
.12
.25
.36
.54
.27
.34
.50
.28
.37
.55
.35
.54
.34
.50
.77
.46
.72
750
1240
545
1575
1180
1630
700
1505
2290
550
1370
2160
1115
1850
2530
2500
2505
3800
3470
.16
.25 .13 .34
.26
.37
.20
.34
.55
.18
.31
.49
.24
.37
.57
.54
.49
.79
.72
700
1270
1090
290
1745
1280
2080
3020
.20
.35
.32
.20
.53
.41
.58
.78
Ship
Wt.
83
83
83
83
84
87
83
83
84
87
100
101
104
111
100
101
104
111
194
195
198
203
196
197
200
205
210
213
220
223
213
216
223
226
Page 42
Loading...