Acme Engineering PDU080 User Manual

Direct Drive Centrifugal Roof/Wall Exhauster
Models PDURF and PDURG Restaurant Exhauster
Models PDURF and PDURG (restaurant exhauster) are direct drive upblast centrifugal exhausters. Capacities up to 5,317 CFM and up to 1 1/4 inch static pressure. The PDURF is a clean air ventilator designed for high velocity vertical discharge. Model PDURG is ideally suited for removal of grease laden exhaust found in restaurant and commercial kitchen applications. Other applications include a wide range of commercial, industrial, and institutional facilities such as schools, hospitals, prisons, and assembly areas.
Centrifugal Exhausters
Construction Features
Housing
Windband constructed of heavy gauge aluminum with rolled
bead for strength Sealed windband perimeter to prevent leakage
Quick release latches allow easy removal of motor
compartment cover without special tools Heavy gauge galvanized wire birdscreen (PDURF only)
Aluminum curb cap
Centrifugal Wheel
Aluminum construction backward curved blade
Non-overloading design for safe operation
Wheel optimally matched with die-formed orifice
Precision balanced for smooth vibration free operation
Motors
Continuous duty motors with sealed ball bearings located
outside the airstream
Large breather tube directs outside air into the motor compartment resulting in maximum life
Motor compartment cooled by fins located on top of impeller
Options/Accessories
DIMENSIONS
Roof
Est.
Fan
Model
PDU080 13.50 13.06 20.63 12.84 9 x 9 23 36 AR8.75 C12 CR12
PDU100 13.50 16.10 20.63 12.84 9 x 9 30 43 AR8.75 C12 CR12 PDU110 13.50 16.41 20.63 12.84 9 x 9 30 43 AR8.75 C12 CR12
PDU120 19.00 19.48 26.41 16.59 14.5 x 14.5 50 72 AR14 C17.5 CR17.5 PDU135 19.00 20.87 26.41 16.59 14.5 x 14.5 50 72 AR14 C17.5 CR17.5
PDU150 24.00 23.89 30.16 21.92 19.5 x 19.5 76 102 AR18 C22.5 CR22.5 PDU165 24.00 23.89 30.16 21.92 19.5 x 19.5 76 102 AR18 C22.5 CR22.5
PDU185 28.00 25.75 34.65 21.99 23.5 x 23.5 94 179 AR22 C26.5 CR26.5 PDU200 28.00 25.75 34.65 21.99 23.5 x 23.5 94 179 AR22 C26.5 CR26.5
Dimensions are shown in inches. Weights are shown in pounds. *Recommended maximum. ‡ Please contact your local representative for correct rated sizing for hurricane construction
AB CD
Acme Engineering & Manufacturing Corporation certifies that the models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Opening
*‡
Unit
Wt.
Est.
Ship
Wt.
Damper
Model
Roof Curb ‡
RF RG
Roof Curbs Dampers Coatings Wall Bracket (PDU080-200) Birdscreen (PDURG) Grease Trough Curb Hinge
Model PDURF is Listed for Electrical (UL/C-UL 705) File No. E39982. Model PDURG is Listed for (UL 762) File No. MH11542.
CSA Certified
Consult your Acme representative for availability.
Page 18
PERFORMANCE DATA
Fan
Model
PDU080 1/10
PDU100 1/10
PDU110 1/10
PDU120E4 1/4
PDU135F6 1/3
PDU135G4 1/2
PDU150F6 1/3
PDU165G6 1/2
PDU185G6 1/2 1160 4340 15.0 4193 15.0 4047 14.5 3900 14.0 3751 13.3 3602 12.6 3426 12.7 .600
PDU200J6 1 1160 5317 19.5 5155 18.2 4994 17.8 4830 17.8 4657 17.0 4483 17.0 4305 16.8 3898 16.1 3415 15.4 1.215
Motor
HP RPM
1600 385 9.7 368 9.5 350 9.2 323 8.8 253 8.5 .040
1300 313 7.4 292 7.7 261 11.0 .020
1630 850 12.0 788 11.8 735 11.3 681 10.6 625 9.6 573 8.9 .085
1300 678 8.3 604 7.8 537 7.5 468 6.9 .042
1550 1017 10.1 951 10.2 885 10.6 816 9.6 731 9.5 617 9.5 506 9.5 .098
1300 853 8.1 774 8.3 693 7.6 588 7.5 454 7.5 270 7.5 .057
1050 689 6.0 591 6.2 468 5.5 292 5.5 .030
860 564 4.5 441 4.2 243 4.2 .016
1680 1753 13.8 1689 13.7 1611 13.6 1522 13.6 1433 13.5 1295 13.2 1155 13.1 .250
1550 1617 13.5 1548 13.5 1457 13.1 1361 12.7 1233 12.4 1082 12.0 .200
1300 1356 10.8 1269 9.9 1154 9.5 1001 9.6 .110
1160 1210 9.0 1106 8.8 972 8.7 770 8.2 .080
860 897 5.3 742 5.3 .030
1160 1840 11.9 1718 11.6 1597 11.1 1470 11.0 1311 10.6
1050 1665 10.5 1531 10.0 1397 9.7 1242 9.4
860 1364 8.5 1201 8.1 1020 7.6
1725 2736 20 2654 19.2 2572 19.2 2491 19.0 2410 18.5 2328 18.4 2243 18.3 2052 18.1 1782 17.5 .540
1550 2458 17.6 2367 17.1 2276 16.9 2186 16.5 2095 16.2 2000 16.1 1897 16.0 1614 15.0
1300 2062 14.0 1953 13.6 1845 13.1 1737 12.9 1619 12.7 1473 12.0
1050 1665 10.5 1531 10.0 1397 9.7 1242 9.4
860 1364 8.5 1201 8.1 1020 7.6
1160 2230 11.6 2073 10.9 1911 9.9 1748 10.0 1583 9.5 1353 8.9 .220
860 1652 8.0 1439 8.4 1218 8.5 909 7.9 .090
1160 3242 18.2 3087 18.5 2934 18.1 2781 17.0 2621 16.2 2439 16.1 2194 15.2 1692 15.9 .500
1050 2935 15.9 2764 16.3 2595 16.0 2421 14.9 2227 13.7 1962 13.4 1680 13.8 .373
860 2404 11.9 2196 12.4 1986 10.7 1725 10.6 1385 10.2 .205
.000" .125" .250" .375" .500" .625" .750" 1.000" 1.250"
CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone CFM Sone
CFM and Sones vs. Static Pressure
Max. BHP
.164
.122
.067
.392
.231
.122
.067
Centrifugal Exhausters
Performance certified is for Installation Type A: Free Inlet, Free Outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5ft) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: Free Inlet hemispherical sone levels. The brake horsepower capability of an exhauster motor is dependent on the degree of cooling the motor receives from the air moving through the motor. The motor loading beyond the motor nameplate rating does not overheat the motor and is in accordance with the motor manufacturer’s recommendations. It is therefore not detrimental to the motor and is economically desirable. Maximum RPM shown obtained with the standard one speed motor, for all other RPM’s use solid state controller.
For more information on this product contact your sales support.
Page 19