Acme Engineering HAF20A4 User Manual

ACME ENGINEERING &
MANUFACTURING CORP.
P.O. Box 978 Muskogee, OK 74402
918/682-7791 FAX 800/382-ACME
www.acmeag.com acmeag@acmefan.com
www.acmehort.com acmehort@acmefan.com
VALU-MASTER Model HAF
Horizontal Air Flow Fan
FANS
Acme’s precise engineering has matched the proper propeller with a continuous duty motor to form a high airflow and low energy consumption fan.
CHECK THESE FEATURES -
Propeller -
efficiency as well as quiet operation.
3 phase, ACME has the right motor for the fan size. All have thermal overload protection and ball bearings. Selected motors can be used with variable speed control for more
precise air movement.
Designed to give the best performance and
From 1/15 HP PSC to ½ HP
PVC Coated Guards - Two piece wire easy-access
guard has a white PVC coating to resist corrosion.
Easy Installation -
provides a locking tilt adjustment for proper angle of air flow. “S” bracket provides two different dimensional mountings. Optional brackets are available for alternate mounting styles.
Factory Wiring -
wired using either a 6 foot 115 volt or 8 foot 230 volt cord with molded plug.
Optional Standard Mounting Bracket
FAN
SIZE
12" 20" 20" 36"
MODEL RPM
uHAF12A4 uHAF20A4
1566
1626 HAF20F4 1686 1/3 115/230/1 60 402.5 5105 12.7 HAF36G8
808 1/2 115/230/1 60 680.0 12280 18.1
36" HAF36G8 808 1/2 200/230/460/3 60 680.0 12280 18.1
* Watt reading is corrected to standard air density. uAvailable with variable speed controller. 200/230/3 dual voltage or 460/3 single voltage
MOTOR
HP
VOLTAGE HZ WATTS*
1/15 115/1 60 124.5 1145 9.2 1/15 115/1 60 105.0 3005 28.6
Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings include the effect of guards.
Two piece standard rotational bracket
All single phase motors come factory
AIR
FLOW
CFM/WATT
THIS UNIT HAS ROTATING PARTS AND SAFETY PRECAUTIONSSHOULD BE EXERCISED DURING INSTALLATION, OPERATION AND MAINTENANCE. OSHA APPROVED GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PEOPLE OR WITHIN 8 FEET (2.5 METERS) OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY. GUARDS
CURRENTLY INSTALLED ON HAF12A4, DO NOT MEET OSHA REQUIREMENTS.
WALL OR POST MOUNTING BRACKET
CEILING MOUNTING BRACKET
HORIZONTAL PIPE MOUNTING BRACKET
LIMITED WARRANTY Acme Engineering and
Manufacturing Corporation extends this limited warranty to the original purchaser and warrants that products described herein shall be free from original defects in workmanship and materials for two years from date of shipment (except for Acme’s exclusive duplex split pillow block bearings and shaft 5 years from shipment, belts one year from shipment, and polyethylene tubing at90 days from shipping), provided same have been properly handled, stored, installed, serviced, maintained and operated. Refer to Form MS149 for complete limited warranty terms and conditions. This form is available to anyone at www.acmefan.com. The Company's warranty is in lieu of all otherwarranties, express or implied, arising by law or otherwise, including without limitation the implied warranties of merchantability and fitness for a particular purpose, which are hereby expressly disclaimed claimed and waived.
ACME ENGINEERING & MANUFACTURING CORP.
P.O. Box 978, Muskogee, Oklahoma 74402 Telephone: 918-682-7791 Fax: 918-682-0134 www.acmeag.com e-mail: acmeag@acmefan.com www.acmehort.com e-mail: acmehort@acmefan.com
VERTICAL PIPE MOUNTING BRACKET
Acme products are designed and manufactured to provide reliable performance but they are not guaranteed to be 100% free of defects. Even reliable products will experience occasional failures and this possibility should be recognized by the Purchaser and End User. If these products are used in a life support ventilation system where failure could result in loss or injury, the Purchaser and End User should provide adequate back-up ventilation, supplementary natural ventilation or failure alarm system, or acknowledge willingness to accept the risk of such loss or injury.
WARNING DO NOT use in HAZARDOUS ENVIRONMENTS where fan’s electrical system could provide ignition to combustible or flammable materials unless unit is specifically built for hazardous environments. Comply with all local and national safety codes including the National Electrical Code (NEC) and National
Member Air Movement and Control Association International, Inc.
Fire Protection Act (NFPA). Guards must be installed when fan iswithin reach of personnel or within eight (8) feet (2.5 m) of working level or when deemed advisable for safety. DISCLAIMER The Company has made a
diligent effort to illustrate and describe the products in this literature accurately; however, such illustrations and descriptions are for the sole purpose of identification, and do not express or imply a warrantythat the products are merchantable, or fit for a particular purpose. INDEMNITY Purchaser acknowledges various
warnings by the Company regarding the products and its installation and use. If the Company incurs any claims, lawsuits, settlements, or expenses (including attorney fees) for any loss, injury, death or property damage including, but not limited to, claims arising out of the Purchaser’s or any end user’s installation or use ofthe products, the Purchaser shall indemnify and hold the Company harmless.
July 2006 Form B147F
Loading...