ACME ENGINEERING &
MANUFACTURING CORP.
P.O. Box 978 • Muskogee, OK 74402
918/682-7791 • FAX 800/382-ACME
www.acmeag.com acmeag@acmefan.com
www.acmehort.com acmehort@acmefan.com
VALU-MASTER
Model HAF
Horizontal Air Flow Fan
FANS
Acme’s precise engineering has matched the proper propeller
with a continuous duty motor to form a high airflow and low
energy consumption fan.
CHECK THESE FEATURES -
Propeller -
•
efficiency as well as quiet operation.
• Moisture Resistant Motor -
3 phase, ACME has the right motor for the fan size. All have
thermal overload protection and ball bearings. Selected
motors can be used with variable speed control for more
precise air movement.
Designed to give the best performance and
From 1/15 HP PSC to ½ HP
• PVC Coated Guards - Two piece wire easy-access
guard has a white PVC coating to resist corrosion.
• Easy Installation -
provides a locking tilt adjustment for proper angle of air flow.
“S” bracket provides two different dimensional mountings.
Optional brackets are available for alternate mounting styles.
• Factory Wiring -
wired using either a 6 foot 115 volt or 8 foot 230 volt cord with
molded plug.
Optional Standard Mounting Bracket
FAN
SIZE
12"
20"
20"
36"
MODEL RPM
uHAF12A4
uHAF20A4
1566
1626
HAF20F4 1686 1/3 115/230/1 60 402.5 5105 12.7
HAF36G8
808 1/2 115/230/1 60 680.0 12280 18.1
36" HAF36G8 808 1/2 ★200/230/460/3 60 680.0 12280 18.1
* Watt reading is corrected to standard air density.
uAvailable with variable speed controller.
★200/230/3 dual voltage or 460/3 single voltage
MOTOR
HP
VOLTAGE HZ WATTS*
1/15 115/1 60 124.5 1145 9.2
1/15 115/1 60 105.0 3005 28.6
Speed (RPM) shown is nominal.
Performance is based on actual speed of test.
Performance ratings include the effect of guards.
Two piece standard rotational bracket
All single phase motors come factory
AIR
FLOW
CFM/WATT
THIS UNIT HAS ROTATING PARTS AND SAFETY PRECAUTIONSSHOULD BE EXERCISED
DURING INSTALLATION, OPERATION AND MAINTENANCE. OSHA APPROVED GUARDS
MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PEOPLE OR WITHIN 8 FEET (2.5
METERS) OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY. GUARDS
CURRENTLY INSTALLED ON HAF12A4, DO NOT MEET OSHA REQUIREMENTS.
WALL OR POST MOUNTING BRACKET
CEILING MOUNTING BRACKET
HORIZONTAL PIPE MOUNTING BRACKET
LIMITED WARRANTY Acme Engineering and
Manufacturing Corporation extends this limited
warranty to the original purchaser and warrants
that products described herein shall be free from
original defects in workmanship and materials
for two years from date of shipment (except for
Acme’s exclusive duplex split pillow block
bearings and shaft 5 years from shipment, belts
one year from shipment, and polyethylene
tubing at90 days from shipping), provided same
have been properly handled, stored, installed,
serviced, maintained and operated. Refer to
Form MS149 for complete limited warranty
terms and conditions. This form is available to
anyone at www.acmefan.com. The Company's
warranty is in lieu of all otherwarranties, express
or implied, arising by law or otherwise, including
without limitation the implied warranties of
merchantability and fitness for a particular
purpose, which are hereby expressly disclaimed
claimed and waived.
ACME ENGINEERING &
MANUFACTURING CORP.
P.O. Box 978, Muskogee, Oklahoma 74402
Telephone: 918-682-7791 Fax: 918-682-0134
www.acmeag.com e-mail: acmeag@acmefan.com
www.acmehort.com e-mail: acmehort@acmefan.com
VERTICAL PIPE MOUNTING BRACKET
Acme products are designed and manufactured
to provide reliable performance but they are not
guaranteed to be 100% free of defects. Even
reliable products will experience occasional
failures and this possibility should be recognized
by the Purchaser and End User. If these
products are used in a life support ventilation
system where failure could result in loss or
injury, the Purchaser and End User should
provide adequate back-up ventilation,
supplementary natural ventilation or failure
alarm system, or acknowledge willingness to
accept the risk of such loss or injury.
WARNING DO NOT use in HAZARDOUS
ENVIRONMENTS where fan’s electrical system
could provide ignition to combustible or
flammable materials unless unit is specifically
built for hazardous environments. Comply with
all local and national safety codes including the
National Electrical Code (NEC) and National
Member Air Movement and Control Association International, Inc.
Fire Protection Act (NFPA). Guards must be
installed when fan iswithin reach of personnel or
within eight (8) feet (2.5 m) of working level or
when deemed advisable for safety.
DISCLAIMER The Company has made a
diligent effort to illustrate and describe the
products in this literature accurately; however,
such illustrations and descriptions are for the
sole purpose of identification, and do not
express or imply a warrantythat the products are
merchantable, or fit for a particular purpose.
INDEMNITY Purchaser acknowledges various
warnings by the Company regarding the
products and its installation and use. If the
Company incurs any claims, lawsuits,
settlements, or expenses (including attorney
fees) for any loss, injury, death or property
damage including, but not limited to, claims
arising out of the Purchaser’s or any end user’s
installation or use ofthe products, the Purchaser
shall indemnify and hold the Company
harmless.
July 2006 Form B147F