ACI-Automation Components WET TO WET Data Sheet

Automation Components, Inc.
WET TO WETPRESSURE
WET TO WET
Dierential Pressure Transducer w/ Remote Probes
The A/WPR2 Series Remote Wet to Wet Differential Pressure Transmitter is designed to reduce installation time and provide mounting flexibility, often eliminating the need for additional plumbing. They accurately measure wet media pressures in a variety of applications. Commonly used for monitoring pumps, these devices are also ideal for measuring pressure across filters, heat exchangers and compressors. The A/WPR2’s enclosure opens conveniently to allow it to be reconfigured between three additional ranges (see order grid) and outputs of 4 to 20 mA (default), 0 to 5 VDC, or 0 to 10 VDC.
A/WPR2 also features a push button auto zero function for remote calibration.
The LCD option will display pressure values for both the High and Low side pressures, a differential pressure value, “OVR” for values over the specified range, “ERROR” for differential pressures out of range, and “ZERO” when the auto-zero is in process.
Automation Components, Inc. Made in the USA
The A/WPR2 Series can measure both uni
55
SPECIFICATIONS
Automation Components, Inc.
Supply Voltage
Supply Current Differential Pressure Output Output Load Resistance Field Selectable Range/Spans
Accuracy Output Update Rate Response Time (0-100% FSO) Thermal Effects Proof Pressure Burst Pressure Operating Temperature Compensated Temperature Range Operating RH Process Fitting Enclosure Rating Product Dimensions
RANGE AND OUTPUT CHART
Series: A/WPR2-30 (Uni-directional) Series: A/WPR2-30 Series: A/WPR2-100 Series: A/WPR2-100 Series: A/WPR2-300 Series: A/WPR2-300
(Bi-directional)
(Uni-directional) (Bi-directional) (Uni-directional) (Bi-directional)
4 to 20 mA Output: 250Ω Load: 16 to 36 VDC | 500Ω Load: 20 to 36 VDC 0 to 5 / 0 to 10 VDC Output: 16 to 36 VDC, 24 VAC +/- 10% 25 mA maximum (current output), 6 mA maximum (voltage outputs)
2 wire: Linear 4-20 mA DC Current (default), 3 wire: 0-5 VDC; 0-10 VDC (field selectable)
4 to 20 mA: 500 ohms maximum | 0 to 5 / 0 to 10 VDC: 5K ohms minimum
3, 7.5, 15 & 30 psi (uni and bi-directional) for 30 psi sensors 10, 25, 50 & 100 psi (uni and bi-directional) for 100 psi sensors 30, 75, 150 & 300 psi (uni and bi-directional) for 300 psi sensors
±1.0% FSO (includes linearity, hysteresis and repeatability) | ±1.5% for 0-10 & 0-30 psi ranges
1 second 8 seconds
±2.0% FSO from 32 to 140°F (0-60°C) 3X F.S (A/WPR2-30 Series) & (A/WPR2-100 Series) | 2X F.S. (A/WPR2-300 Series)
1500 psi
Sensors: -30 to 120°C (-22 to 248°F) | Electronics/Housing/Cables: 0 to 75°C (32 to 167°F) 32 to 140°F (0 to 60°C)
10 to 90% RH non-condensing 1/4"-18 NPT Male (304 stainless steel); Pressure Snubber included for light oils/water for WPR2-100
NEMA 4X/IP66
Enclosure: (L) 5.10” (W) 3.93” (H) 3.00”
Uni-directional Range: 0-30 psi
Default Selectable Bi-directional Range: Default
Uni-directional Range: 0-100 psi Selectable Bi-directional Range: Default Uni-directional Range: Selectable Bi-directional Range:
±30 psi
±100 psi
0-300 psi
±300 psi
Selectable Uni-directional Ranges: Selectable Bi-directional Ranges: Selectable Uni-directional Ranges: Selectable Bi-directional Ranges: Selectable Uni-directional Ranges: Selectable Bi-directional Ranges:
15, 7.5 & 3 psi
±15, ±7.5 & ±3 psi
0-50, 25 & 10 psi
±50, ±25 & ±10 psi
0-150, 75 & 30 psi
±150, ±75 & ±30 psi
ORDERING
Select a Sensor Series (A), one Wiring Harness (B), & one LCD Option (C). NOTE: For maximum line pressures less than 100 psi, you should select the A/WPR2-100 Series and for maximum line pressures between 100 and 300 psi, you should select the A/WPR2-300 Series. The jumpered output range should be selected based upon the maximum expected differential pressure rather than the maximum line pressure. In addition, for applications in which the maximum line pressure is 10 PSI or below with a maximum differential pressure of 5 lbs or less we recommend the use of the A/WP Series Differential pressure with a 3 Valve Manifold for best results.
Sensor Series
A/WPR2-30 A/WPR2-100 A/WPR2-300
Wiring Harness
10’ 20’
LCD Option
---- (No LCD) LCD
BUILD PART NUMBER
After completing (A), (B) & (C) from the above table, fill in the Part Number Table below. An example part number is offered.
EXAMPLE: A/WPR2-100 - 10’ - LCD
56