ACI-Automation Components THERMISTORS Data Sheet

Automation Components, Inc.
THERMISTORSTEMPERATURE
R2 Enclosure
Room with Setpoint & Override
Room, Setpoint
Room, Override
Room
Room, Override
Room, Setpoint,
Override
Room, Setpoint
Room (Infinity)
Stainless Plate
Stainless Plate,
Override
Brass Button Sensor
Stainless Button Sensor
Plastic Button Sensor
THERMISTORS
Wall Mounting
ACI offers a comprehensive list of wall mounting configurations for Thermistors (see list above). These sensors provide a predictable and accurate output over the specified temperature range. Each sensor configuration is designed and manufactured for long-term quality and performance. The most prominent of the series is the R2 wall mount enclosure which features a sleek and modern design. ACI wall mount enclosures offer the option of having a customized logo. Certain minimums, special part numbers, and specific artwork file types may be required. Please contact ACI for further details regarding custom labels. The ACI Button Series is an unobtrusive option for unique applications. This series is offered in brass, stainless steel, and plastic to blend into a wide array of decors.
Automation Components, Inc. Made in the USA
9
TEMPERATURE THERMISTORS
Automation Components, Inc.
SPECIFICATIONS
Accuracy (0-70oC) Stability Interchangeability Operating Temperature Range PBS Housing Material Sensor Output [A/AN] Sensor Output [A/CP] Sensor Output [A/3K] Sensor Output [A/1.8K] Sensor Output [A/20K] Sensor Output [A/100KS]
Single Point: +/-0.2oC (+/-0.36oF)
o
+/-0.13
C (+/-0.23oF)
o
+/-0.2
C (+/-0.36oF) 32 to 122 ABS Compound (low smoke) 10KΩ @ 77°F (Type III) 10KΩ @ 77°F (Type II)
3KΩ @77°F (25°C)
1.8KΩ @77°F (25°C) 20KΩ @77°F (25°C) 100KΩ @77°F (25°C)
o
F (0 to 50oC)
Sensor Output [A/10KS] Sensor Output [A/2252] Sensor Output [A/CSI] Sensor Output [A/AN-BC] Sensor Output [A/10K-E] Sensor Output [A/10K-E1] Setpoint Tolerance Power Dissipation Constant Operating Humidity Range Product Dimensions
10KΩ @77°F (25°C) 2252Ω @77°F (25°C) 10KΩ @77°F (25°C) 10KΩ with 11K Shunt 10KΩ @77°F (25°C) 10KΩ @77°F (25°C)
+/- 10% of the range
o
C
3 mW/ 0 to 90% RH non-condensing Please reference pages 7 & 8
ORDERING
Select one Series (A), one Enclosure (either Aries or Infinity) (B), & one Communication Jack (C). When selecting your Configuration (B) if “R2S”, “RS”, “RSO” or “R2SO” please choose a Pot Value (D), an Offset Resistor (E), Sticker (F) & a Pot Action (G). If ”R2S”, “RS”, “RSO” or ”R2SO” is not selected, your Part Number is finished after completing Communication (C). If a Stainless Plate or Button Sensor (1) is desired, please add a Stainless Plate (SP), Brass Button Sensor (BBS), Stainless Button Sensor (SBS), or a Plastic Button Sensor (PBS) to the separate Part Number below. NOTE:
Sections (D) through (G) are for internal references and will not be displayed in your final part number. *Regarding the Sensor Series (1) and
Additional Configuration (2), the A/10KS and A/AN-BC are not avilable as PBS.
Room Sensor Series Aries Enclosure Infinity Enclosure
A/AN (Type lll)
(Type ll)
A/CP A/3K A/1.8K
Pot Value
400 1K 2K 5K
8.5K 10K 20K 100K
A/20K A/100KS A/10KS A/2252
A/CSI A/AN-BC A/10K-E A/10K-E1
Offset Resistor
0Ω (Default) 499Ω 806Ω 910Ω
R2 (Room)
(Room, Setpoint)
R2S
(Room, Override)
R2O
(Room, Setpoint, Override)
R2SO
1KΩ 2KΩ
4.99K
6.19K
7.32K
8.25K 10K 20K
Blue/Red (R2 Only) Cool/Warm 55 to 85°F 10 to 30°C
Sticker
R (Room)
(Room, Setpoint)
RS
(Room, Override)
RO
(Room, Setpoint, Override)
RSO
Pot Action
DA (Direct)
(Reverse)
RA
Communication
RJ4 (4 Pin/Conductor)
(6 Pin/Conductor)
RJ6
(Stereo Jack)
RS232
(No Jack)
----
Sensor Series Additional Configuration
A/AN A/CP A/3K A/1.8K
A/20K A/100KS A/10KS* A/2252
A/CSI A/AN-BC* A/10KE A/10KE1
SP (Stainless Plate)
(Stainless Plate, Override)
SP-OR
BBS
(Brass Button Sensor) (Stainless Button Sensor)
SBS
PBS*
(Plastic Button Sensor)
BUILD PART NUMBER
After completing (A), (B), (C), (D), (E), (F) & (G) from the above table, fill in the “Part Number Table” below. (1) & (2) are additional configurations. An “example” part number is offered.
10
EXAMPLE: A/AN - R2 - RJ6
EXAMPLE: A/AN - SP
The R2 & R enclosures have a UL94-HB flammability rating.
Loading...