ACI-Automation Components ROOM Data Sheet

Automation Components, Inc.
R
R-LCD
R2
TEMPERATURE | TRANSMITTERS | ROOM
ROOM
Wall Mount Enclosures, Transmitter
The ACI Transmitter Room Series features a two-wire, 4 to 20 mA loop powered output with optional 3-Wire voltage output signals available. All transmitters include Zero and Span adjustments for eld calibration and are calibrated using NIST Certied Calibration equipment. ACI recommends the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to reduce the chances of noise being introduced onto the signal lines. The room transmitters are designed to be mounted over a standard single gang junction box or hole in the wall and includes a foam pad to reduce the eects of self-heating from the transmitter and thermal drafts from within the wall. For best accuracy, ACI recommends the use of the A/TTM Series Matched transmitters with 3 or 5 Point NIST Calibration Certicate, since they include a second calibration step in which the RTD and transmitter are calibrated together as a system.
Applications: Space Temperature Sensing, Oce Buildings, Schools, Gyms, Manufacturing Plants, Pharmaceutical, Hospitals, Data Centers
PRODUCT SPECIFICATIONS
Optional Set Point, Override and Loop Powered LCD Display.
Transmitter Supply Voltage | Supply Current:
Maximum Load Resistance: Output Signals: Calibrated Transmitter Accuracy | Linearity: Temperature Drift: TTM100/TTM1K Certication Points: Warm Up Time | Warm Up Drift: Calibrated Temperature Spans: Connections | Wire Size: Terminal Block Torque Rating: Override Contact Type | Contact Ratings: Set Point Accuracy:
Sensor Type | Sensor Curve | Sensing Points: Number Wires | Wire Colors (TTM Series only): Nominal Sensor Output @ 0°C (32°F): RTD Tolerance Class | Sensor Accuracy:
Din Standard | Temperature Coecient: Sensor Stability: LCD Display Input Signal: LCD Display Accuracy: LCD Display Descriptor | Resolution: LCD Display Life Expectancy: Operating Temperature Range: Storage Temperature Range: Operating Humidity Range: Enclosure Specications (Material Type, Color UL Flammability Rating): Foam Pad Material | Flammability Rating (TTM Only): Product Dimensions: Product Weight:
Agency Approvals:
Note: Transmitter’s calibrated at 71ºF (22ºC) nominal | Note: Temperature Drift is referenced to 71ºF nominal calibration temperature | Note: Temperature spans may go outside of the operating
temperature range but the unit must be used within the operating temperature limit
+8.5 to 32 VDC (Reverse Polarity Protected) | 25 mA minimum
250 Ohm Load: +13.5 to 32 VDC | 500 Ohm Load: +18.5 to 32 VDC “-LCD” Loop Powered: Add +7 VDC to 250/500 Ohm Load Supply Voltage above
(Terminal Voltage - 8.5 V) | 0.020 A
Current: 4-20 mA (2-Wire Loop Powered) | Voltage: 1-5 VDC or 2-10 VDC (3-Wires) Temp. Spans < 500ºF (260ºC): +/- 0.2% Temp. Spans < 100ºF (38ºC): +/- 0.04%/ºF | Temp. Spans > 100ºF (38ºC): +/- 0.02% 3 Point NIST: 20%, 50% & 80% of span | 5 Point NIST: 0%, 20%, 50%, 80% & 100% of span
0.37 ft-lb (0.5 N-3m ) nominal Dry Contact “N/O” Contact | Minimum: 10 uA @ 1 VDC | Maximum: 50 mA @ 24 VDC +/- 10% | 4-20 mA: 4 mA (Far Left) / 20 mA Far Right (DA- Direct Acting (Default) 20 mA (Far Left / 4 mA Far Right (RA- Reverse Acting (Optional) Platinum RTD | PTC (Positive Temperature Coecient) | One Two | A/TTM100-R/R2: Brown/Brown | A/TTM1K-R/R2: Black/Black A/TT100/TTM100-R/R2: 100 Ohms | A/TT1K/TTM1K-R/R2: 1000 Ohms +/- 0.06% Class A | (Tolerance Formula: +/- ºC = (0.15ºC + (0.002 * |t|)) where |t| is the absolute value of temperature above or below 0ºC in ºC DIN EN 60751 (IEC 751) | 3850 ppm / ºC +/- 0.03% after 1000 Hours @ 300ºC (572ºF) 4 to 20 mA Only (2-wire Loop Powered) +/- 1.0% of Calibrated Temperature Span or +/- Whichever is Greater ºF (Fahrenheit) or ºC (Celsius) | 3 ½ Digits (-199.9 to 199.9) 50,000 Hours Minimum 35 to 122ºF (1.5 to 50ºC) Non-LCD: -40 to 65ºC (-40 to 149ºF), LCD Display: -10 to 65ºC (14 to 149ºF) 5 to 90% RH, non-condensing
“-R2” Enclosure: ABS Plastic, White, UL94-HB “-R” Enclosure: ABS Plastic, Beige , UL94-HB
Neoprene/EPDM/SBR Polymer | UL94-HBF; FMVSS-302; MIL-R-6130C
4.50” (114.3 mm) x 2.78” (70.6 mm) x 1.00” (25.4 mm)
“-R/RS/RO” Series: 0.17 lbs. (0.375 kg) | “-RSO” Series: 0.21 lbs. (0.46 kg) “-R2/R2S/R2O” Series: 0.19 lbs. (0.42 kg) | “-R2SO” Series: 0.23 lbs. (0.51kg) All LCD Display Units: 0.174 lbs. (0.079 kg)
RoHS2, WEEE
Call: 1-888-967-5224 | Web: www.workaci.com
TEMPERATURE | ##
TEMPERATURE | TRANSMITTERS | ROOM
DIMENSIONAL DRAWING
Automation Components, Inc.
2.75” (69.85mm)
R R2 R RR2
4.50”
(114.30mm)
2.75” (69.85mm)
4.50”
(114.30mm)
1.12” (28.55mm)
1.12” (28.55mm)
Front View Right View Top View
CUSTOM ORDERING |
A. Sensor Series
B. Model Series
C. Conguration
No Selection Required
Select One (1)
Select One (1)
STANDARD ACCURACY
A/
TT100 = 100 Ohm Platinum RTD | TT1K = 1K Ohm Platinum RTD
R = Room | RO = Room with Override | RS = Room with Set Point
Model # Example:
A/A.TT100
B. E.
RSO = Room with Set Point and Override | R2 = Room | R2O = Room with Override R2S = Room with Set Point | R2SO = Room with Set Point and Override
Select One (1)
Select One (1)
1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mAD. Output Signal
---- = No LCD Display | LCD = With LCD DisplayE. LCD Display
Specify Span in ºF or ºC (Best Accuracy in 100ºF Increments)F. Calibrated Span
Setpoint Conguration Options
1.
Potentiometer
2.
Setpoint Indication
Note*: Best transmitter accuracy with spans in 100ºF Increments (ie. 0 to 100ºF or 1.5 to 40ºC
Select One (1)
Select Options below if RS, RSO, R2S or R2SO was selected as a Conguration (C).
4-20 mA
Select One (1)
+ to - | Blue | Red | Cool | Warm | Cooler | Warmer | 10 to 30C | 18 to 28C | 55 to 85F
R2SOC.4 LCD
D.
R2
10 to 30C
4-20 mA40 to 90ºF
1.F.
2.
MODEL #
A/
CUSTOM ORDERING |
A. Sensor Series
B. Model Series
C. Conguration
No Selection Required
Select One (1)
Select One (1)
Select One (1)
HIGHER ACCURACY
A/
TTM100 = Matched 100 Platinum RTD | TTM1K = Matched 1K Platinum RTD*
R2 = Room | R = Room
1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mAD. Output Signal
Specify Span in ºF or ºC (Best Accuracy in 100ºF Increments)E. Calibrated Span
Note* = Must specify a 3 or 5 Point NIST Certicate with the TTM1K Transmitter above
ACCESSORIES ORDERING
Model #
A/MOUNTING PLATE
A/MOUNT PLATE WHITE
LOCKING COVER
A/ROOM-FOAM-PAD
Item #
106821
126386
107370
125690
Description
Wall Mounting Back Plate, Plastic, Beige
Wall Mounting Back Plate, Plastic, White
Clear Thermostat Guard, Locking Cover, Low Prole
1/8” Foam Insulation Pad with Adhesive (3” x 2”, Black)
Model # Example:
A/A.TTM1K
B.
RC.4
Model # Example:
5 Point
0 to 100ºF
D.
E.
F.
MODEL #
A/
-OR-
106821A/MOUNTING PLATE
TEMPERATURE | ##
Revision C0000002 | Rev 1.0
Call: 1-888-967-5224 | Web: www.workaci.com