ACI-Automation Components RIGID AVERAGING Data Sheet

Automation Components, Inc.
GD
BB
PB
4X
TEMPERATURE | TRANSMITTERS | RIGID AVERAGING
RIGID AVERAGING
Continuous Averaging, Transmitter
The ACI Transmitter Rigid Averaging Series features a two-wire, 4 to 20 mA loop powered output signal with an optional 3-Wire voltage output signal available. The Rigid Averaging sensors are designed to be installed in small to medium size ducts to give you a better average compared to that of a single point sensor. All transmitters include Zero and Span adjustments for eld calibration and are calibrated using NIST Certied Calibration equipment. ACI recommends the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to help eliminate the possibility of noise being introduced onto the signal lines. The 1K Ohm Rigid Averaging sensor assemblies include a continuous sensing element the covers the entire length of the stainless steel probe and are manufactured using colored Etched Teon lead wires to dierentiate between the dierent sensor types. All units are hermetically sealed using our epoxy material to eliminate the eects of moisture on the
limit vibration once installed. Optional NEMA/IP rated weather proof enclosures are available as specied on the back of the product data sheet. For best accuracy, ACI recommends the use of the A/TTM Series Matched transmitters with a 3 or 5 Point NIST Calibration Certicate, since they include a second calibration process in which the RTD and transmitter are calibrated together as a system. On larger ducts, our bendable copper averaging transmitter should be used for better coverage and control of the air inside of the duct.
Applications: Roof Top Units, Air Handlers, Monitoring Supply/Discharge/Return/Mixed Air Temperatures, Data Centers, Hospitals
sensors. The Rigid Averaging transmitters include a foam pad to properly seal the duct and
PRODUCT SPECIFICATIONS
Transmitter Supply Voltage | Supply Current:
Maximum Load Resistance: Output Signals: Calibrated Accuracy | Linearity: Thermal Drift: Min/Max Temperature Spans: TTM100/TTM1K NIST Certication Points: Warm Up Time | Warm Up Drift: Transmitter Operating Temperature Range: Connections | Wire Size: Terminal Block Torque Rating: Sensor Type | Sensor Curve | Sensing Points: Number Wires | Wire Colors: Sensor Output @ 0°C (32°F): Sensor Accuracy: Din Standard | Temperature Coecient: Response Time (63% Step Change): Sensor Operating Temperature Range: Enclosure Specications (Operating Temperature, Material, Flammability, NEMA/IP Ratings):
Storage Temperature Range: Operating Humidity Range: Probe Diameter | Probe Material: Fitting Material | Flammability Rating: Fitting Thread Size: Foam Pad Material | Flammability Rating: Lead Length | Conductor Size: Lead Wire Insulation | Wire Rating: Conductor Material: Product Dimensions | Product Weight: Agency Approvals:
Note: Transmitter’s calibrated at 71ºF (22ºC) nominal | Note: Temperature Drift is referenced to 71ºF nominal calibration temperature
+8.5 to 32 VDC (Reverse Polarity Protected) | 25 mA minimum 250 Ohm Load: +13.5 to 32 VDC | 500 Ohm Load: +18.5 to 32 VDC (Terminal Voltage - 8.5 V) | 0.020 A
Current: 4-20 mA (2-Wire Loop Powered) | Voltage: 1-5 VDC or 2-10 VDC (3-Wires) Temp. Spans < 500ºF (260ºC): +/- 0.2% Temp. Spans < 100ºF (38ºC): +/- 0.04%/ºF | Temp. Spans > 100ºF (38ºC): +/- 0.02% Minimum Span: 50ºF (28ºC) | Maximum Span: 400ºF (204ºC) 3 Point NIST: 20%, 50% & 80% of span | 5 Point NIST: 0%, 20%, 50%, 80% & 100% of span
10 Minutes | +/- 0.1%
-40ºF to 185ºF (-40 to 85ºC) Screw Terminal Blocks (Polarity Sensitive) | 16 AWG (1.31 mm) to 26 AWG (0.129 mm)
0.37 ft-lb (0.5 Nm ) nominal Platinum RTD | PTC (Positive Temperature Coecient) | Continuous Three | Black/Black/White (Polarity Sensitive) 1000 Ohms nominal +/- 0.1% @ 0ºC (32ºF) | +/- 0.25% @ 21ºC (70ºF) | +/- 1.0% @ 130ºC (266ºF) DIN EN 60751 (IEC 751) | 3850 ppm / ºC 15 Seconds nominal
-40 to 135ºC (-40 to 275ºF)
“-GD” Enclosure: -40 to 115ºC (-40 to 239ºF); Galvanized Steel; NEMA 1 (IP10) “-PB” Enclosure: -30 to 90ºC (-22 to 194ºF); ABS Plastic; UL94-HB; Plenum Rated “-BB” Enclosure: -40 to 115ºC (-40 to 239ºF); Aluminum; NEMA 3R (IP 14) “-4X” Enclosure: -40 to 70ºC (-40 to 158ºF); Polystyrene Plastic; UL94-V2; NEMA 4X (IP 66)
-40 to 80ºC (-40 to 176ºF) 5 to 90% RH, non-condensing
0.250” (6.35mm) | 304 Stainless Steel Polyamide 66 (High Performance Nylon 66) | UL94-HB 1/8”-27 NPSM Neoprene/EPDM/SBR Polymer | UL94-HBF; FMVSS-302; MIL-R-6130C 12” (30.5 cm) | 22 AWG (0.65mm) Etched Teon (PTFE) Colored Leads | Mil Spec 16878/4 Type E Silver Plated Copper See table on back of Product Data sheet RoHS2, WEEE
Call: 1-888-967-5224 | Web: www.workaci.com
TEMPERATURE | ##
TEMPERATURE | TRANSMITTERS | RIGID AVERAGING
DIMENSIONAL DRAWING, WEIGHTS
Plastic Box Enclosure [PB]
3.60”
(91.44mm)
Galvanized Enclosure [GD]
Bell Box Enclosure [BB]
2.25”
(57.15mm)
4.79” (121.55mm)
3.88” (98.60mm)
2.95”(75mm)
4.79”
(121.55mm)
4.20”
(106.68mm)
2.35” (59.80mm)
Available with 12”, 18”, 24”, and 36” Probe Lengths
Available with 12”, 18”, 24”, and 36” Probe Lengths
1.78” (45.18mm)
Available with 12”, 18”, 24”, and 36” Probe Lengths
2.34” (59.38mm)
Automation Components, Inc.
xx = Sensor Type | yy = Insertion Length
Plastic Box Enclosure [PB] Weights
ACI Model #
A/xx-RA-yy-PB
ACI Model #
A/xx-RA-yy-PB
Galvanized Enclosure [GD] Weights
ACI Model #
A/xx-RA-yy-GD
ACI Model #
A/xx-RA-yy-GD
Bell Box Enclosure [BB] Weights
ACI Model #
A/xx-RA-yy-BB
ACI Model #
A/xx-RA-yy-BB
12” (Probe Length)
0.28 lbs. (0.127 kg)
24” (Probe Length)
0.32 lbs. (0.145 kg)
12” (Probe Length)
0.70 lbs. (0.317 kg)
24” (Probe Length)
0.78 lbs. (0.354 kg)
12” (Probe Length)
0.74 lbs. (0.336 kg)
24” (Probe Length)
0.78 lbs. (0.354 kg)
18”
0.30 lbs. (0.136 kg)
36”
0.36 lbs. (0.163 kg)
18”
0.74 lbs. (0.336 kg)
36”
0.82 lbs. (0.372 kg)
18”
0.78 lbs. (0.354 kg)
36”
0.84 lbs. (0.381 kg)
(Probe Length)
(Probe Length)
(Probe Length)
(Probe Length)
(Probe Length)
(Probe Length)
NEMA 4X Enclosure [4X]
Available with 12”, 18”, 24”, and 36” Probe Lengths
2.24” (56.77mm)
3.88”(98.60mm)
3.70” (93.98mm)
3.70”
(93.98mm)
Standard Views
PRODUCT WEIGHT
Model #
A/TT1K-RA-18”-x-PB A/TT1K-RA-18”-x-GD A/TT1K-RA-18”-x-BB A/TT1K-RA-18”-x-4X A/TT1K-RA-24”-x-PB A/TT1K-RA-24”-x-GD
Weight (lbs.)
0.32
0.76
0.80
0.44
0.35
0.79
Weight (kg)
0.145
0.345
0.363
0.200
0.159
0.358
CUSTOM ORDERING
A. Sensor Series
B. Model Series
C. Conguration
E. Output Signal
Note* = Must specify a 3 or 5 Point NIST Certicate with the TTM1K Transmitter above
No Selection Required
Select One (1)
No Selection Required
Select One (1)
Select One (1)
Select One (1)
A/
TT1K = 1K  RTD, Temperature Transmitter | TTM1K = 1K  Matched RTD/Transmitter*
RA = Rigid Averaging
12” = 12” Probe | 18” = 18” Probe | 24” = 24” Probe | 36” = 36” ProbeD. Probe Length
1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mA
GD = Galvanized | PB = Plastic | BB = Aluminum | 4X = NEMA 4XF. Enclosure
Specify Span in ºF or ºC (Best Accuracy in 100ºF Increments)G. Calibrated Span
NEMA 4X Enclosure [PB] Weights
ACI Model #
A/xx-RA-yy-4X
ACI Model #
A/xx-RA-yy-4X
Model #
A/TT1K-RA-24”-x-BB A/TT1K-RA-24”-x-4X A/TT1K-RA-36”-x-PB A/TT1K-RA-36”-x-GD A/TT1K-RA-36”-x-BB A/TT1K-RA-36”-x-4X
Model # Example:
A/
A.
TT1K
RAC.24”D.1E.GD
B.
12” (Probe Length)
0.38 lbs. (0.172 kg)
24” (Probe Length)
0.44 lbs. (0.200 kg)
Product Weights
Weight (lbs.)
0.83
0.47
0.43
0.89
0.91
0.57
(Probe Length)
18”
0.40 lbs. (0.181 kg)
(Probe Length)
36”
0.50 lbs. (0.227 kg)
Weight (kg)
0.376
0.213
0.195
0.404
0.413
0.259
0 to 40ºC
F.
G.
MODEL #
A/
RA
TEMPERATURE | ##
Revision C0000002 | Rev 1.0
Call: 1-888-967-5224 | Web: www.workaci.com