ACI-Automation Components Q5 Data Sheet

Automation Components, Inc.
Q5GAS
Q5
Toxic & Combustible Sensor
The Q5 Series is a microprocessor based “smart” gas transmitter. It is paired with either an electrochemical gas sensor for toxic gases, or a catalytic bead sensor for combustible gases. Pre-calibrated sensors can be purchased and installed by the user, thereby reducing calibration costs and minimizing downtime. The user can select from numerous display options, including relay status, time, TWA, STEL, concentration, or nothing at all. All programming and calibration is nonproprietary and is accessed through a user selectable password which protects system integrity.
Automation Components, Inc.
GAS Q5
Automation Components, Inc.
SPECIFICATIONS
Supply Voltage DC Supply Voltage AC Sensor Type Sensor Life Span Gas Measurement Range Outputs Sampling Method Accuracy/Repeatability (Combustible) Buzzer Rating Enclosure Rating Indicators Operating Temperature Range Operating Humidity Range Relay Rating Maximum Sensor Coverage Area Mounting Height Above Floor Approvals Product Dimensions
24 VDC nominal, range 18 to 30 VDC, 0.3A DC total maximum 24 VAC nominal, range 15 to 24 VAC, 0.3A AC Total maximum (AC must not be grounded) Electrochemical or Infrared (Toxic) or Catalytic Bead (Combustible) (see ordering grid below) 2 to 3 years typical (toxic gas), >5 yrs in clean environment See ordering information 4-20 mA, 1-5 VDC, 2-10 VDC, Digital RS-485, Modbus, 3 Relays Diffusion or flow through +/- 2.0% of LEL/+/- 2.0% of LEL Rated for 80 dB @ 10 cm, 2,700 Hz with 3 programmable tones IP66 and NEMA 4, 4X, 12 and 13 Backlit LCD graphic display | (5) LED’s for Relay and RS-485 Status
o
-40
to 70oC (-40o to 158oF), depends on sensor specification 5 to 95%, non-condensing (3) SPDT 2 Form C Rated 1A @ 30 VDC | 0.3A @ 125 VAC 7,500 ft2 (CH4,C3H8,CO,O2,H2,NH3,NO,NO2): 5,000 ft2 (CL2,CLO2,HCL,HCN,H2S,O3,SO2) Contact ACI or visit www.workaci.com Q5CO** (ANSI/UL 2075) | All other Models: (CAN / CSA C22.2 NO 61010-1); conforms to UL 61010-1 (H) 5.90” (W) 3.54” (D) 2.55”
ORDERING
Select one Gas Type (A), and include “Span” when filling out Part Number. *NOTE: If “GENL” is selected (A), please specify gas type. Choose “O” as an Enclosure (B). (1) is an Optional Accessory.
Gas Type
Q5-CH3CO-100L (Acetone, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Ammonia, Electrochemical, 0-100 PPM) (Span: 100P)
Q5-NH3
(Ammonia, Electrochemical, 0-1000 PPM) (Span: 1000P)
Q5-NH3
(Arsine, Electrochemical, 0-1 PPM) (Span: 1P)
Q5-ASH3 Q5-C6H6 Q5-C4H10 Q5-BUTAN Q5-CO2 Q5-CO2 Q5-CO2 Q5-CO2 Q5C-CO** Q5C-CO** Q5-CL2 Q5-CLO2 Q5-GENL* Q5-B2H6 Q5-C2H4 Q5-ETO Q5-GEH4
(Benzene, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Iso-Butane, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Butanol,n-Butane,Catalytic Bead,0-100% LEL)(Span: 100L) (Carbon Dioxide, Infrared, 0-5000 PPM) (Span: 5000P) (Carbon Dioxide, Infrared, 0-5% VOL) (Span: 5V) (Carbon Dioxide, Infrared, 0-20% VOL) (Span: 20V) (Carbon Dioxide, Infrared, 0-100% VOL) (Span: 100V)
(Carbon Monoxide,Electrochemical,0-250 PPM)(Span: 250P)
(Carbon Monoxide,Electrochemical,0-1000 PPM)(Span: 1000P)
(Chlorine, Electrochemical, 0-5 PPM) (Span: 5P)
(Chlorine Dioxide, Electrochemical, 0-2 PPM) (Span: 2P)
(Combustible, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Diborane, Electrochemical, 0-2 PPM) (Span: 2P) (Ethylene, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Ethylene Oxide, Electrochemical, 0-20 PPM) (Span: 20P)
(Germaine, Electrochemical, 0-2 PPM) (Span: 2P)
Enclosure
O (Standard Enclosure)
Q5-H2
(Hydrogen, Electrochemical, 0-1000 PPM) (Span: 1000P) (Hydrogen, Electrochemical, 0-2000 PPM) (Span: 2000P)
Q5-H2
(Hydrogen, Catalytic Bead, 0-100% LEL) (Span: 100L)
Q5-H2
(Hydrogen Bromide,Electrochemical,0-30 PPM)(Span: 30P)
Q5-HBR
(Hydrogen Chloride, Electrochemical,0-30 PPM)(Span: 30P)
Q5-HCL
(Hydrogen Cyanide, Electrochemical,0-50 PPM)(Span: 50P)
Q5-HCN
(Hydrogen Sulphide, Electrochemical,0-25 PPM)(Span: 25P)
Q5-H2S
(Hydrogen Sulphide,Electrochemical,0-100 PPM)(Span: 100P)
Q5-H2S
(Methane, Catalytic Bead, 0-100% LEL) (Span: 100L)
Q5-CH4 Q5-CH3OH Q5-NO Q5-NO2 Q5-O2 Q5-O3 Q5-C5H12 Q5-PH3 Q5-PH3 Q5-C3H8 Q5-SIH4 Q5-SO2
(Methanol, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Nitric Oxide, Electrochemical, 0-100 PPM) (Span: 100P)
(Nitrogen Dioxide, Electrochemical, 0-10 PPM) (Span: 10P) (Oxygen, Electrochemical, 0-25% VOL) (Span: 25V) (Ozone, Electrochemical, 0-1 PPM) (Span: 1P)
(Iso-Pentane, Catalytic Bead, 0-100% LEL) (Span: 100L) (Phosphine, Electrochemical, 0-1 PPM) (Span: 1P) (Phosphine, Electrochemical, 0-5 PPM) (Span: 5P)
(Propane, Catalytic Bead, 0-100% LEL) (Span: 100L)
(Silane, Electrochemical, 0-50 PPM) (Span: 50P)
(Sulphur Dioxide, Electrochemical, 0-6 PPM) (Span: 6P)
Optional Accessory
85930-006-000 (Enclosure, Pump-Thru Cap Kit) 85930-007-000 85930-040-000
(Enclosure, Splash Guard Kit) (Enclosure, Duct Mount Kit)
BUILD PART NUMBER
After completing (A) & (B) from the above table, fill in the Part Number Table below. The “Sensor Series” & “Revision” (X) are factory defaults. (1) is an Optional Accessoriy. An example part number is offered.
106
SENSOR SERIES
EXAMPLE: Q5C - CO - 250P - O - X
OPTIONAL ACCESSORY
O X
SPAN FACTORY PROVIDED
Loading...