ACI-Automation Components GP SERIES Data Sheet

Automation Components, Inc.
PRESSURE | GP SERIES GAGE PRESSURE
GP SERIES
Gage Pressure Transducer (Air, Gasses, & Liquid)
The GP Series is designed to provide excellent accuracy and reliability in commercial, industrial, and process control applications where performance is critical. The bulk micro-machined transducer features a stainless steel diaphragm with welded construction that contains no O-rings, which makes them compatible with any gas or liquid compatible with 304L stainless steel. Some of the compatible gases and liquids include refrigerants, glycol, motor oil, diesel, hydraulic uid, brake uid, water, waste water, Hydrogen, Nitrogen and air. The GP Series transducers can also be ordered in an optional NEMA 4 rated, weatherproof metal enclosure (See on-line GP-NEMA 4 data sheet) or a NIST Calibration Certicate. Accessory items such as pressure snubbers and pigtail syphons are available to protect the transducers from line pressure surges (pulsations) or extreme operating temperatures. This series features packard connectors and seperate harnesses allowing for installation exibility.
Applications: Refrigeration, Fuel Cells, Pumps, Hydraulics, Compressors, Robotics, Pneumatics, Agriculture, Spraying Systems, Process Control, Flow, Hydrogen Storage, Steam Lines, Boilers, Chillers
PRODUCT SPECIFICATIONS
Supply Voltage:
Reverse Polarity Protection:
Maximum Load Resistance:
Supply Current:
Output Signal:
Pressure Ranges:
Accuracy  @ 22ºC (71.6ºF):
Thermal Error  (-40º to 105ºC):
Stability (250 Hours @ 225ºF (125ºC)):
Proof Pressure:
Burst Pressure:
Thermal Shock:
Vibration (100 to 2000Hz, 20g Sinusoidal, 3 Axes):
Operating Temperature Range:
Storage Temperature Range:
Operating Humidity Range:
Media Types:
Transducer Housing Material:
Process Fitting Material | Thread Size:
Recommend Torque Specication:
Wiring Connections:
NIST Certicate:
Approvals:
Product Dimensions (Length x Diameter):
Product Weights:
Note: Accuracy includes Hysteresis, Repeatability, and Non-linearity (BFSL) | Note: Additional error over temperature range | Note: Sealed Gage pressure transducers are not vented
to atmosphere, but are calibrated to have 4 mA at 14.5 PSIG to resemble a standard gauge pressure transducer output
250 Ohm Load: +13 to 30 VDC | 500 Ohm Load: 18 to 30 VDC
+/- 16 V over 5 minutes
800 Ohms @ 24 VDC | Formula: (Supply VDC – 8 VDC) / 0.020A
25 mA minimum
4 to 20 mA (2-Wire, Loop Powered)
< 1 ms
See “Ordering Grid” on back of data sheet
15 to 60 psig: < +/- 1.0% FS | 75 to 300 psig: < +/- 0.5% FS | 500 psis : < +/- 0.5% FS
15 to 60 psig: < +/- 1.0 FS | 75 to 300 psig: < +/- 0.5% FS | 500 psis : < +/- 0.5% FS
+/- 0.03% FS @ 0 PSIG; +/- 0.12% FS @ 1000 PSIG
15 to 300 psig: 3x FS | 500 psis: 3x FS
15 to 300 psig: 3x FS | 500 psis: 3x FS
300 Cycles (105ºC to -40ºC, 0.5 hr soaks @ Temp. (2s Transfer))
144 Hours
-40 to 221ºF (-40 to 105ºC)
-40 to 176ºF (-40 to 80ºC)
0 to 95% RH, non-condensing
Any gas or liquid compatible with 304L Stainless Steel
Stainless Steel
304L Stainless Steel | 1/4”-18 NPT
150 lbs-in (16.95 N-m)
Packard Connector (Cables ordered separately per “Ordering Grid” on back of data sheet)
Ordered Separately (See “Ordering Grid” on back of data sheet)
EMC Compliance: 10 V/m (EN61000-4-3), CE, RoHS2, WEEE, ISO 9001
2.60” (66.6 mm) x 0.875” (22.23 mm)
A/GP Series Transducer: 0.30 lbs. (0.136 kg) | A/GP 2’ Harness: 0.09 lbs. (0.040 kg)
A/GP 6’ Harness: 0.20 lbs. (0.091 kg) | A/GP 10’ Harness: 0.32 lbs. (0.145 kg)
A/GP 20’ Harness: 0.62 lbs. (0.282 kg) | A/GP 30’ Harness: 0.92 lb.s (0.417 kg)
A/GP 40’ Harness: 1.22 lbs. (0.554 kg)
PRESSURE | ##
PRESSURE | GP SERIES GAGE PRESSURE
DIMENSIONAL DRAWING
1/4” - 18 NPT Male Thread
Automation Components, Inc.
2.77”
(70.36mm)
Ø0.87”
(22.07mm)
0.88”(22.35mm)
0.71” (18.03mm)
1.06” (27.00mm)
Front View Right View
STANDARD ORDERING
Model #
GP(0-15G)-20-P
GP(0-30G)-20-P
GP(0-50G)-20-P
GP(0-100G)-20-P
GP(0-200G)-20-P
GP(0-300G)-20-P
GP(0-500S)-20-P
Item #
135751
143160
143161
135747
135748
135749
135750
Description
0-15 psig (103 kPa), ¼” NPT, Packard
0-30 psig (207 kPa), ¼” NPT, Packard
0-50 psig (345 kPa), ¼” NPT, Packard
0-100 psig (689 kPa), ¼” NPT, Packard
0-200 psig (1379 kPa), ¼” NPT, Packard
0-300 psig (2069 kPa), ¼” NPT, Packard
0-500 psis (3447 kPa), ¼” NPT, Packard
Gage
Sealed Gage
•
ACCESSORIES ORDERING
Model #
A/GP 2’HARNESS
A/GP 6’HARNESS
A/GP 10’HARNESS
A/GP 20’HARNESS
A/GP 30’HARNESS
A/GP 40’HARNESS
A/0.25”SNUB A/G
A/0.25”SNUB WTR
GP NIST*
Note*: The A/GP Harness and GP NIST must be ordered separately when ordering transducers w/ Packard Connector or any of the Gage Pressure transmitters with a NIST Calibration Certicate
Item #
142606
135614
116601
135613
135703
136995
137105
137104
142927
Description
A/GP 2’ (.61m) Packard Wire Harness, Plenum Rated
A/GP 6’ (1.83m) Packard Wire Harness, Plenum Rated
A/GP 10’ (3.05m) Packard Wire Harness, Plenum Rated
A/GP 20’ (6.10m) Packard Wire Harness, Plenum Rated
A/GP 30’ (9.14m) Packard Wire Harness, Plenum Rated
A/GP 40’ (12.19m) Packard Wire Harness, Plenum Rated
¼” NPT Stainless Steel Snubber for Air/Gas
¼” NPT Stainless Steel Snubber for Water/Light Oils
GP NIST Calibration Certicate
0.78” (19.81mm)
Model # Example:
Packard Connector
Model # Example:
-OR-
GP(0-300G)-20-P
Harness Required
135749
-OR-
135703A/GP 30’ HARNESS
PRESSURE | ##
Revision C0000001 | Rev 1.0