![](/html/a5/a54e/a54e393a882873aa2a4e10f743d330f2077da4e5c5e69ca8048d9aa3f0177859/bg1.png)
Automation Components, Inc.
FREEZER RTDSTEMPERATURE
Galvanized Raco Box
NEMA 4X
Featured Freezer RTD Product
Glycol Bottle (Left), 3PT Glycol Bottle (Right)
NEMA 3R
Lead Wire
FREEZER RTDS
Platinum RTDs
The A/100-LTS, A/1K-LTS, A/TT100-LTS, and A/TT1K-LTS Series sensors and temperature transmitters
incorporate a Class B, wire wound platinum RTD sensor which conforms to DIN-IEC-751 and DIN 43760
platinum RTD standards. They are designed to withstand the extreme temperature fluctuations that
cause issues with standard temperature sensors in your typical freezer application. The ACI A/TTM Series
offers a matched calibration of the sensor and transmitter, which improves the measurement accuracy. An
N.I.S.T. certificate is provided with all A/TTM Series devices. Robust, high- end performance in addition to
N.I.S.T certification makes this series suitable for applications such as pharmaceutical or scientific
laboratories.
Automation Components, Inc. Made in the USA
27
![](/html/a5/a54e/a54e393a882873aa2a4e10f743d330f2077da4e5c5e69ca8048d9aa3f0177859/bg2.png)
TEMPERATURE
SPECIFICATIONS
FREEZER RTDS
Automation Components, Inc.
Sensor Accuracy (single point)
Sensor Accuracy (formula)
Sensor Accuracy Class
Combined Sensor & Transmitter Accuracy
Stability
Repeatability
Sensor Operating Temperature Range
Temperature Coeffcient
Standardization
Product Dimensions (Lead Wire)
Product Dimensions (Glycol Kit)
Product Dimensions (Glycol-3 PT-Kit)
Product Dimensions (NEMA 3R)
Product Dimensions (NEMA 4X)
Product Dimensions (Galvanized Raco Box)
* [t] = Numerical value of the temperature in oC without taking into account positive or negative signs.
+/-0.54oF @ 32oF (0oC)
o
0.3
C + 0.005 X [t] = maximum error C*
Class B Tolerance
+/-1.5% span
less than +/-0.1
o
+/-0.3
-198 to 150
0.00385 Ohm/Ohm/
DIN-IEC-751 (formerly DIN 43760)
(L) 6, 10, 30, 50 & 100’
Bottle: (H) 3.39” (DIA) 1.53” Bracket: (L) 1.50” (W) 1.82” (H) 2.60”
Bottle: (H) 4.04” (DIA) 2.62” Bracket: (L) 3.00” (W) 2.63” (H) 3.36”
(H) 4.58” (W) 2.82” (D) 2.25”
(H) 3.70” (W) 2.55” (D) 2.22”
(H) 4.20” (W) 2.326” (D) 1.979”
o
C (+/-0.54oF)
C drift
o
C (-324 to 302oF)
o
C
ORDERING
Select one Series (A) & specify Span if necessary (parts with TT require spans & outputs). Choose one Output (B), one Housing (C) & one Lead
Wire (D). If a Bottle, or an additional accessory is desired, please complete (1) below. NOTE:
10’ leads.
Sensor Series Output Housing
A/100-LTS (100Ω Platinum RTD)
A/1K-LTS
A/TT100-LTS
A/TT1K-LTS
A/TTM100-LTS
A/TTM1K-LTS
(1,000Ω Platinum RTD)
(Transmitter, 100Ω RTD)
(Transmitter, 1,000Ω RTD)
(Matched Transmitter)
(Matched Transmitter)
---- (Resistive)
1
(1 to 5 VDC)
2
(2 to 10 VDC)
4
(4 to 20 mA)
---- (No Housing)
GD
(Galvanized Raco Box)
4X
(NEMA 4X)
BB
(NEMA 3R)
The A/TT100-LTS Series is only available with 6 or
Lead Wire
6’ (6 Foot Leads)
10’
(10 Foot Leads)
30’
(30 Foot Leads)
50’
(50 Foot Leads)
Glycol (Bottle, Accessories)
A/GLYCOL-BOTTLE
A/GLYCOL-BRACKET
A/GLYCOL-KIT
A/GLYCOL-3PT-BOTTLE
A/GLYCOL-3PT-BRACKET
A/GLYCOL-3PT-KIT
(Single Probe)
(Bracket Only)
(Mounting Bracket & Glycol Bottle)
(Single Probe)
(Bracket Only)
(Mounting Bracket & Glycol Bottle)
BUILD PART NUMBER
After completing (A), (B), (C) & (D) from the above table, fill in the Part Number Table below. (1) is an additional configuration. An example part
number is provided.
EXAMPLE: A/TT100-LTS - 1 - 4 - 4X - 10’
EXAMPLE: A/GLYCOL BOTTLE
28