ESENSE: CO2
ESENSE Carbon Dioxide Sensor
The ESENSE room and duct transmitters monitor the carbon dioxide (CO2) levels in industrial, school, and office-type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The ESENSE Series is based on a single beam non-dispersive infrared technology and is a cost-optimized solution for the climate control of buildings and other processes. In addition, ABC software eliminates the need for manual calibration. The ESENSE Series measures the CO2 concentration in the ambient air up to 2,000 ppm and converts the data into an analog output. This data can be used in conjunction with a Building Automation or Demand Control Ventilation System. This decreases energy consumption while creating a healthier indoor climate. Units come with combined output options of 0-5 VDC and 4 to 20 mA or 0-10 VDC and 4 to 20 mA.
Automation Components, Inc.
95
GAS
SPECIFICATIONS
ESENSE: CO2
Automation Components, Inc.
Supply Voltage Power Consumption Measurement Range Default Output Signal Accuracy Repeatability Annual Zero Drift Pressure Dependence Response Time Warm Up Time Operating Temperature/Relative Humidity Range Sensor Coverage Area Life Expectancy Sensing Technology Product Dimesions (Room Mount) (US) Product Dimesions (Duct Mount) Product Dimesions (Industrial Wall Mount) Product Dimesions (In Duct/Wall Mount)
24 VAC/VDC +/-20%, 50/60 Hz (half-wave rectifier) < 1 Watt average (for OUTDOOR when heater is off) 0 to 2,000 ppm (up to 10,000 ppm with software adjustment) 0-5 VDC and 4-20 mA or 0-10 VDC and 4-20 mA +/- 30 ppm +/- 3% of reading +/- 20 ppm +/- 1% of reading < +/- 10 ppm + 1.6% reading per kPa < 10 seconds @ 30 cc/minute flow rate | < 3 minute diffusion time < 1 minute (@ full specs < 15 minutes) 32 to 122 7,500 sq. ft. maximum > 15 years (typical) Single beam infrared sensing technology (NDIR) (H) 5.12” (W) 3.35” (D) 1.18” (H) 5.98” (W) 3.33” (D) 1.85” (H) 5.98” (W) 3.33” (D) 1.85” (H) 5.12” (@) 3.35” (D) 1.18”
o
F (0 to 50oC)/0 to 95%, non-condensing (-22 to 115oF for OUTDOOR)
ORDERING
Select one Enclosure (A), one Output (B) & one Display (C). When selecting an Enclosure (A), if a “D” Duct Mount (IP65) is selected, complete (B), (C) & (D). All other Enclosure (A) options are finished after selecting a Display (C).
Enclosure Output Display
R (Room (US)) (Only Complete B & C)
(Room (European)) (Only Complete B & C)
RE
(Duct (IP65)) (Complete B, C & D)
D
(Wall Mount) (Only Complete B & C)
IP54
(In Duct/Wall Mount (Only Complete B)
IP50 OUTDOOR
(IP65 Housing w/ in-line heater) (Only Complete B)
---- (0-10 VDC & 4-20 mA) (0-5 VDC & 4-20 mA)
5
---- (None) (Standard) (LCD Display)
LCD
Adapter
---- (None) (Conduit)
C
BUILD PART NUMBER
After completing (A), (B), (C) & (D) from the above table, fill in the Part Number Table below. The “Sensor Series” is a factory default. An example part number is offered.
ESENSE
SENSOR SERIES
EXAMPLE: ESENSE - IP50 - 5
96