ACI-Automation Components A/100-3W-LT-O-BB, A/1K-3W-LT-O-BB Data Sheet

Automation Components, Inc.
TEMPERATURE | LOW TEMP TRANSMITTERS | OUTSIDE AIR
OUTSIDE AIR
Low Temperature Outside Air Sensor & Transmitters
The ACI Low Temperature Outside Air Series temperature sensors and transmitters are a single point sensor featuring a three wire RTD sensor assembly with a 316 Series stainless steel probe. The three wire sensors can be used with a two wire transmitter by connecting the two (Red) colored wires to one of the RTD terminal blocks with the 3rd wire (White) wire connected to the second RTD Terminal block. The purpose of the 3rd wire is to compensate for external lead wire resistance that will aect the accuracy of your sensor output when using with a three wire temperature transmitter or sensor conguration on your Building Management System or PLC (Programmable Logic Controller. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using the A/100/1K-3W-O style Platinum RTD series sensors without temperature transmitter. The operating specications are for both the sensor and transmitter as designated in the specication table. The transmitter is mounted in the
mounted in the Aluminum Bell Box for mounting outdoors due to the extreme temperatures. NIST Certicates are available for all of the congurations listed in the ordering grid on the back of the product data sheet. For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters with a 3 or 5 Point NIST Calibration Certicate since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, which will remove most of the sensor error over the calibrated temperature span of the transmitter.
Applications: Freezers, Outside Air Temperature, Cold Storage Facilities, Manufacturing Facilities, Process Control
Galvanized junction and should be mounted inside your building with the sensor assembly
PRODUCT SPECIFICATIONS
Transmitter Supply Voltage | Supply Current:
Maximum Load Resistance: Output Signals: Calibrated Transmitter Accuracy | Linearity: Temperature Drift: Warm Up Time | Warm Up Drift: Operating | Storage Temperature Range: Operating Humidity Range: Calibrated Temperature Spans: Connections | Wire Size: Terminal Block Torque Rating: Sensor Type | Sensor Curve | Sensing Points: Number Wires: Sensor Output @ 0°C (32°F): Sensor Tolerance Class | Accuracy: Din Standard | Temperature Coecient: Sensor Stability: Response Time (63% Step Change): Self-Heating | Maximum Operating Current:
Sensor Operating Temperature Range: Enclosure Specications (Operating Temperature Range, Material, Flammability, NEMA/IP Ratings): Storage Temperature Range: Operating Humidity Range: Probe Material | Probe Diameter: Compression Fitting Material: Lead Length | Conductor Size: Lead Wire Insulation | Conductor Material: Product Dimensions | Product Weight: Agency Approvals:
Note: Transmitter’s calibrated at 71ºF (22ºC) nominal | Note: Where |t| is the absolute value of temperature above or below 0ºC in Centigrade)
+8.5 to 32 VDC (Reverse Polarity Protected) | 25 mA minimum 250 Ohm Load (1-5 VDC): +13.5 to 32 VDC | 500 Ohm Load (2-10 VDC): +18.5 to 32 VDC (Terminal Voltage - 8.5 V) | 0.020 A
Current: 4-20 mA (2-Wire Loop Powered) | Voltage: 1-5 VDC or 2-10 VDC (3-Wires) Temp. Spans < 500ºF (260ºC): +/- 0.2% | Temp. Spans > 500ºF (260ºC): +/- 0.5% Temp. Spans < 100ºF (38ºC): +/- 0.04%/ºF | Temp. Spans > 100ºF (38ºC): +/- 0.02%
10 Minutes | +/- 0.1%
-40ºF (-40ºC) to 185ºF (85ºC) 0 to 90%, non-condensing Minimum Temp. Span: 50ºF (28ºC) | Maximum Temp. Span: 800ºF (426ºC) Screw Terminal Blocks (Non-Polarity Sensitive) | 16 AWG (1.31mm) to 26 AWG (0.129mm)
0.5 Nm nominal Platinum RTD | PTC (Positive Temperature Coecient) | One
A/100-3W-LT-O and A/1K-3W-LT-O: Three (Two Red / White) Polarity Sensitive) A/100-3W-LT- O: 100 Ohms nominal | A/1K-3W-LT-O: 1000 Ohms nominal
+/- 0.12% Class B | Class B Tolerance Formula: +/- ºC = (0.30ºC + (0.005 * |t|)) DIN EN 60751 (IEC 751) | 3850 ppm | ºC < 0.04 % at 1000 hours at 400ºC 15 Seconds nominal
100 Ohm RTD: 7 mW | ºC (Still Air) | 5 mA 1K Ohm RTD: 4 mW | ºC (Still Air) | 3 mA
-10 to 395ºC (-40 to 743ºF)
“-GD” Enclosure: -40 to 199ºC (-40 to 390ºF); Galvanized Steel; NEMA 1 (IP10) “-BB” Enclosure: -75 to 85ºC (-103 to 185ºF); Aluminum; NEMA 3R (IP 14)
-40 to 85ºC (-40 to 185ºF) 5 to 100% RH 316 Stainless Steel | 0.250” (6.35mm) 316 Stainless Steel 8’ (2.44 m) | 22 AWG (0.25 mm) Etched Teon (PTFE) | Silver Plated Copper See table on back of Product Data sheet RoHS2, WEEE
Call: 1-888-967-5224 | Web: www.workaci.com
TEMPERATURE | ##
TEMPERATURE | LOW TEMP TRANSMITTERS | OUTSIDE AIR
DIMENSIONAL DRAWING, WEIGHTS
4.70” (119.38mm)
2.95” (74.93mm)
Front View Right View Top View, Product Weight
Automation Components, Inc.
2.28”
2.34”
(57.912mm)
(59.436mm)
Bell Box Enclosure [BB] Weight
ACI Model #
A/xx-3W-LT-O-BB
Weight
0.94 lbs. (0.252 kg)
xx = Sensor Type
STANDARD ORDERING
Model #
A/100-3W-LT-O-BB
A/1K-3W-LT-O-BB
CUSTOM ORDERING |
A. Sensor Series
B. Model Series
C. Number of Wires
E. Conguration
G. NIST
No Selection Required
Select One (1)
No Selection Required
No Selection Required
No Selection Required
No Selection Required
Select One (1)
CUSTOM ORDERING |
A. Sensor Series
B. Model Series
D. Conguration
No Selection Required
Select One (1)
No Selection Required
No Selection Required
Select One (1)
No Selection Required
Item #
142523
125205
Description
100 Ohm RTD, 3-Wire, Outside Air Sensor, Aluminum Weather Proof Enclosure, 8 Foot Leads
1K Ohm RTD, 3-Wire, Outside Air Sensor, Aluminum Weather Proof Enclosure, 8 Foot Leads
LOW TEMPERATURE OUTSIDE AIR
A/
100 = 100 Ohm Platinum RTD only | 1K = 1K Ohm Platinum RTD only
3W = Three Wires (Specify for 100 and 1K RTD Sensors only)
LT = Low Temperature SeriesD. Low Temperature
O = Outside Air
BB = Cast Aluminum Weather Proof Enclosure F. Enclosure
---- = No NIST Certicate | NIST = NIST Certicate (Must Specify 1, 3 or 5 Points)
LOW TEMPERATURE OUTSIDE AIR TRANSMITTERS
A/
TT100 = Unmatched Temperature Transmitter & 100 Ohm RTD TT1K = Unmatched Temperature Transmitter & 1K RTD TTM100 = Matched 100 Ohm Temperature Transmitter/Sensor TTM1K = Matched 1K Ohm Temperature Transmitter/Sensor
(Must specify 3 or 5 Point NIST Certicates for all TTM100 and TTM1K Transmitters)
LT = Low Temperature SeriesC. Low Temperature
O = Outside Air
1 = 1 to 5 VDC | 2 = 2 to 10 VDC | 4 = 4 to 20 mA E. Analog Output
BB = Cast Aluminum Weather Proof Enclosure F. Enclosure
Specify Span in ºF or ºC (Best Accuracy in 100ºF Increments)G. Calibrated Span
Model # Example:
Model # Example:
A/A.1K
B.
A/A.TT100
B.
3WC.LT
LTC.O
Model # Example:
D.
D.
A/1K-3W-LT-O-BB
OE.BBF.NIST
2E.BB
F.
G.
G.
-OR-
125205
MODEL #
A/
3W
LT
O
BB
MODEL #
A/
LT
O
BB
TEMPERATURE | ##
Revision C0000002 | Rev 1.0
Call: 1-888-967-5224 | Web: www.workaci.com
Loading...