Acer Veriton M2632G instruction booklet

Product type
Product category B C D
Manufacturer name, address
Product model number
Year of manufacture
E
allowance with capability adjustments when discrete graphics cards are disabled (from 1 July 2014)
197 kWh/year 213 kWh/year 248 kWh/year
E
allowance with capability adjustments when discrete graphics cards are enabled (from 1 July 2014)
266 kWh/year 282 kWh/year 317 kWh/year
E
allowance with capability adjustments when discrete graphics cards are disabled (from 1 January 2016)
151 kWh/year 159 kWh/year 187 kWh/year
E
allowance with capability adjustments when discrete graphics cards are enabled (from 1 January 2016)
189 kWh/year 197 kWh/year 225 kWh/year
Whether all discrete graphics card are enabled during the test
No Yes Yes
Whether switchable graphics mode with UMA is driving the display during the test
Not applicable No No
E
of highest power-demanding configuration
127.58 kWh/year 160.89 kWh/year 146.41 kWh/year
Idle state power demand 33.81 Watt 43.29 Watt 39.14 Watt
Sleep mode power demand 2.45 Watt 2.55 Watt 2.69 Watt
Sleep mode with WOL enabled power demand
2.53 Watt 2.63 Watt 2.78 Watt
Off mode power demand 0.36 Watt 0.36 Watt 0.36 Watt
Off mode with WOL enabled power demand
0.36 Watt 0.36 Watt 0.36 Watt
Maximum power demand Not applicable Not applicable Not applicable
Internal power supply (IPS) efficiency at 10 %, 20 %, 50 % and 100 % of rated output power
10% - 91.14% 20% - 93.31% 50% - 90.89% 100% - 99.04%
10% - 91.14% 20% - 93.31% 50% - 90.89% 100% - 99.04%
10% - 91.14% 20% - 93.31% 50% - 90.89% 100% - 99.04%
External power supply's (EPS) average active efficiency
Not applicable Not applicable Not applicable
Noise levels (the declared A-weighted sound power level, L
WAd
) of idle mode
3.3 B 3.3 B 3.3 B
Noise levels (the declared A-weighted sound power level, L
WAd
) of "HDD random
seek" mode
3.3 B 3.3 B 3.3 B
Minimum number of loading cycles that the batteries can withstand
Not applicable Not applicable Not applicable
Technical Documentation of (EU) No 617/2013
Desktop computer
Acer Italy s.r.l, Via Lepetit, 40, 20020 Lainate (MI) Italy
Veriton M2632
2014
Configuration of memory 2 ~ 16 GB 2 GB 4 ~ 16 GB
Configuration of internal storage 1 piece 1 piece 1 piece
Configuration of discrete television tuner 0 piece 0 piece 0 piece
Configuration of discrete audio card 0 piece 0 piece 0 piece
Configuration of discrete graphics cards 0 piece 1 piece 1 piece
Configuration of discrete graphics cards category
Not applicable G3 G3
The battery in this product cannot be easily replaced by users themselves
Not applicable Not applicable Not applicable
For products with an integrated display, the total content of mercury is
Not applicable Not applicable Not applicable
Measurement methodology for ETEC
Measurement methodology for idle mode
Measurement methodology for sleep mode
Measurement methodology for off mode
Measurement methodology for IPS efficiency
Measurement methodology for EPS efficiency
EN 62623:2013 — Desktop and notebook computers —
Measurement of energy consumption:
5.2. Test setup;
5.3.5. Measuring short idle mode;
5.7. True RMS watt meter specification;
5.8. True RMS watt meter accuracy; Annex E.2 (informative) ENERGY STAR® V5 compliant testing
methodology.
EN 62623:2013 — Desktop and notebook computers —
Measurement of energy consumption
5.2. Test setup;
5.3.3. Measuring sleep mode;
5.4. Test conditions;
5.7. True RMS watt meter specification;
5.8. True RMS watt meter accuracy.
EN 62623:2013 — Desktop and notebook computers —
Measurement of energy consumption
5.2. Test setup;
5.3.2. Measuring off mode;
5.4. Test conditions;
5.7. True RMS watt meter specification;
5.8. True RMS watt meter accuracy.
Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.6 (April,2012).
Not applicable
COMMISSION REGULATION (EU) No 617/2013 of 26 June 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for computers and computer servers: ANNEX II Ecodesign requirements and timetable:
1.1.1. E
formula.
Loading...