ACE Controls VC Precision Hydraulic Feed Controllers User Manual

Installation Instructions
VC Precision Hydraulic Feed Controllers
Mounting block can be installed anywhere on the body.
Optional Thread Mount on flat surfaces using ACE mounting block. May also be installed in suitable machined hole. Do
not use set screws.
Mounting Block
M25 x 1.5
23435 Industrial Park Drive Farmington Hills, Michigan 48335 tel: 248.476.0213 fax: 248.476.2470
www.acecontrols.com
Piston rod must butt directly against object to be controlled. It should not contact object at an angle exceeding 1 .
0
0
2 max
1. Do not exceed 1,500 in/min (38 m/min) velocity without consulting factory.
2. VC may be mounted in any position.
3. To prevent internal damage, do not twist (rotate) VC plunger.
4. Operating temperature range: 32 to 140 F (0 to 60 C)
0000
5. Protect unit from weld flash, petroleum based fluids and external damage.
6. Contact factory when the VC must be exposed to an oil environment.
7. Adjustment instructions: a) To increase feed rate, rotate adjustment knob counterclockwise. b) To decrease feed rate, rotate adjustment knob clockwise.
0
1 max
ACE Controls Inc.
World leader in deceleration technology
ISO 9001:2000 Certified
ACE Form 15, VC
04/01/2004