ACE Controls AGS-15 User Manual

23435 Industrial Park Drive Farmington Hills, Michigan 48335 tel: 248.476.0213 fax: 248.476.2470
www.acecontrols.com
Gas Spring Adjustment Instructions
Utilizing Adjusting Knob for AGS-15
CAUTION: units are filled with gas under pressure. It is recommended to use extreme caution to avoid personal injury. Use safety glasses and avoid pointing the gas spring at yourself or others while adjusting.
1. Hold gas spring cylinder upward (meaning piston rod downward). Valve is included in the cylinder thread. If necessary, unscrew the end fitting off the cylinder.
2. Screw the adjusting knob (M5-KNOB) on the thread until resistance is felt.
3. Screw slowly until you can hear the pressure escaping, then immediately turn the adjusting knob back so that the valve closes again.
NOTE: to avoid overbleeding, adjust in small increments. In the event that overĀ­ bleeding occurs, units can be returned to ACE and repressurized for a nominal cost.
4. Repeat the release procedure as often as necessary.
Closed
Open
Insert
Rotate to
bleed
ACE Controls Inc.
Innovation in Deceleration and Motion Control ISO 9001
23435 Industrial Park Drive Farmington Hills, Michigan 48335 tel: 248.476.0213 fax: 248.476.2470
www.acecontrols.com
Gas Spring Adjustment Instructions
Utilizing Adjusting Knob for AGS-19, AGS-22 and AGS-28
CAUTION: units are filled with gas under pressure. It is recommended to use extreme caution to avoid personal injury. Use safety glasses and avoid pointing the gas spring at yourself or other persons while adjusting.
1. Hold gas spring cylinder upwards (meaning piston rod downwards). Valve is included in the cylinder thread. If necessary, unscrew the end fitting off the cylinder.
2. Screw adjusting knob on the thread until resistance is felt. (Part M8-KNOB for models AGS-19 and AGS-22 or part M10-KNOB for model AGS-28).
3. Screw slowly until you can hear the pressure escaping, then immediately turn the adjusting knob back so that the valve closes again.
NOTE: to avoid overbleeding, adjust in small increments. In the event that overĀ­ bleeding occurs, units can be returned to ACE and repressurized for a nominal cost.
4. Repeat the release procedure as often as necessary.
Rotate to