YT12B-BS
10 Ah | 12 V | 160 A
Mechanical SpecificationsElectrical Specifications
Nominal voltage
Nominal capacity (25 °C)
CCA -10 °C
CCA -18 °C
12 V
10 Ah @10 hrs
100 A
160 A
Retention of Charge During Storage @ 25 °C
1 month
3 months
6 months
12 months
97 %
90 %
80 %
40 %
Directly mounted
Directly mounted
Constant voltage: 14.4 V
Limit current: 2 A
Charging time: 2 - 3 hrs
Constant voltage: 14.4 V
Limit current: 2 A
Charging time: 4 - 6 hrs
Measurements (L x W x H)
Approx. weight
Storage status
Cover
Terminal
Container bottom
Positive plate
Negative plate
Separator
Electrolyte
Safety valve
Way of sealing
150 x 70 x 130 mm
3.12 kg
Wet
ABS
C9 (Cu)
ABS
PbO
2
Pb
AGM
Diluted sulphuric acid
Rubber
Epoxy Resin
130 mm
150 mm
70 mm
Discharge Current 25 °C Residual Capacity
13.0
12.0
11.0
10.0
9.0
8.0
Terminal Voltage (V)
7.0
100 A
6.0
0 1 2 5 10 20 30 60 2 3 5 10 20 30
30 A 10 A
min hrs
Discharge Time
1 A
100
80
60
40
20
Residual Capacity (%)
0 3 6 9 12 15 18
T: +49 7141 / 560 90 40 | F: +49 7141 / 560 90 49
40 °C
Storage Period (months)
batterium GmbH | Robert-Bosch-Straße 1
71691 Freiberg am Neckar | Germany
30 °C
0 °C
10 °C
25 °C