Accurate Thermal Systems FTBSL15 Specifications

Accurate Thermal Systems
Fluidized Temperature Baths
Model FTBSL
15 & FTBSL25
AP PL IC A T I O N S
Nitinol stent shape setting
General heat treatment of devices & materials
Temperature sensor and system calibration
Heating of reactors
Thermal analysis of circuits & components
BE NE FI T S
Large working volume –
7.3”
diameter
25” depth
4000 and 6000 watt heat capacity
Excellent stability and uniformity throughout operating range
Designed and manufactured in USA
CE marked
by 15” and
Fluidized Temperature Baths
Fully automatic Fluidizing air control
Advanced 4 temperature zone PID controller
Cover and lid design that controls and minimizes media loss
Independent over-temperature limit protection
Included RS485 computer interface with Windows PC control and scheduling software
Optional interface for control from any PC on the corporate network
Model FTBSL15 with particulate collar
With over 25 years of experience with Fluidized Bath technology we have developed a range of products that offer outstanding performance, safety and value that are unmatched. Unlike competing Fluidized baths our systems have a smaller footprint, include advanced features and cost thousands of dollars less and are much safer than salt baths with thermal response that is 2 to 3 times faster than ovens. Our systems offer a versatile and open workspace while providing excellent temperature stability and uniformity. Fluidized Temperature Baths have been the heat source of choice for over 20 years by many leading Fortune 500 medical device manufacturers and research companies who require fast heat up of their immersed devices and materials with minimal quenching.
Features and
Specifications
MODEL FTBSL1
5 & FTBSL2
5
Lid with optional parts basket
4104 Sylon Blvd
WH AT ’ S I N C L UD ED
-Fluidized Bath
-bath media
-Bath cover and Lid
-RS485 interface, cable and Windows PC software
-Instruction manual
-particulate extraction collar
WH AT D O I N EE D TO RU N TH E S YS TE M
-240 VAC mains, 50/60hz ­20 amp supply (
-30 amp supply
Clean dry air supply at a fixed
40 PSI, max flow of 3.5 CFM
FTBSL15)
(FTBSL25) -
Specifications
SER VIC E S A VAI LAB LE
-Technical support
-Application support
-Installation and setup
-Maintenance
V15 9/17
Hainesport, NJ 08036 USA
Ph: 609-326-3190
Fax: 609-479-5124
Email: sales@accuthermal.com
Website: www.accuthermal.com
Model FTBSL15 FTBSL15 FTBSL25 FTBSL25
Temperature range 50 to 605°C
Bath media Brown Aluminum
Working volume, inches 7.25 x 15 7.25 x 15 7.25 x 25 7.25 x 25
Typical stability at 500°C ±0.3 ±0.15 ±0.6 ±0.4
Calibrated accuracy - ±3.0 ±3.0 ±3.0 ±3.0
Radial uniformity at 500°C (depth, inches) 0.6° (10) 0.2° (10) 1.0° (15) 0.5° (15)
Axial uniformity at 500°C (over 9 inch range) 1.0° 0.8° 1.5° 1.2°
Heat up time to 500°C, 240V supply 135 minutes 65 minutes 180 minutes 100 minutes
Cool down time – 500 to 200°C 215 minutes 195 minutes 215 minutes 200 minutes
Power – 240 V, single phase, 50/60 hz. 4000 watts 4000 watts 6000 watts 6000 watts
Air pressure & flow required, max 40 PSI(2.76 bar), 3.5 CFM (100 lpm)
Overall footprint, H x W x D - inches 27 x 24 x 21 27 x 24 x 21 41 x 24 x 21 41 x 24 x 21
Total weight with aluminum oxide 210 lbs 165 lbs 360 lbs 270 lbs
RS485 USB interface & PC software Included
Catalog number ATS2019 ATS2022 ATS2021 ATS2023
Optional Accessories
Recommended spare lid ATS1040
Parts basket – 6.5” diameter x 6.5” D ATS1086
Tiered basket – 1.5” deep x 6.7”W (Qnty) ATS1098 (2) ATS1098 (2) ATS1096 (4) ATS1096 (4)
Parts catch basket ATS1099 ATS1099 ATS1097 ATS1097
Accurate Thermal Systems have developed an innovative cover and lid system that minimizes media loss out of the bath opening keeping the operating area cleaner and media loss to a minimum. Media is either blocked by the lid or collected on the cover flange which drops back into the system. The included particulate exhaust collar when used with an exhaust blower and cyclone will capture media when it rises out of the bath.
The lid that is placed onto the cover contains a handle that is elevated above the lid away from heat. The lid can be easily modified by customers to suspend devices, mandrels or apparatus for immersion of devices into the bath or can be used with the optional parts basket. Thermo- wells can also be added for calibration of a quantity of temperature sensors and systems.
White Activated
oxide
alumina
Brown Aluminum
oxide
White Activated
alumina
Loading...