Accurate Thermal Systems FTBLL26 Operating Manual

DIAGRAM #1
If the installation site has a fume exhaust hood present then the following components are all that is required. IMPORTANT: the exhaust needs to be strong enough to completely pulls fumes from the bath to prevent combustion.
4106 Sylon Blvd Hainesport, NJ 08036 www.accuthermal.com Ph: 609-326-3190
Fume Exhaust Hood
Customer supplied
and installed
Bath lid
Tooling to be cleaned
With this basic type of system use the following baskets. Model Part # FTBLL12 ATS1022 FTBLL26 ATS1024 FTBLL27 ATS1053 FTBLL47 ATS1030
Parts basket
900.0
900.3
Fluidized Temperature Bath
DIAGRAM #2
The following system will extract fumes venting them into a new stack or tie into existing plant exhaust
ATS1033
Extraction fan
4106 Sylon Blvd Hainesport, NJ 08036 www.accuthermal.com Ph: 609-326-3190
Stack or existing exhaust ventilation
Air damper
With this type of system use the following baskets. Model Part # FTBLL12 ATS1023 FTBLL26 ATS1025 FTBLL27 ATS1053 FTBLL47 ATS1030
ATS1021 Extraction collar Note: This collar is not needed with model FTBLL47 & FTBLL27
**
**
With parts in the bath and lid on, the damper would be adjusted so fumes and smoke are pulled away from the bath and into the exhaust system. If the damper is open too much it would create a negative pressure in the bath working area resulting in significant heat and sand loss. The purpose of the Cyclone is to recover any sand pulled out and heavier deposits which can be sieved and reused.
**
ATS1032 Cyclone
DIAGRAM #3
The following system will filter out fumes and smoke in the HEPA rated filtration system. The filtered air can be released outside or vented into your plant stack.
ATS1032 Cyclone
Air damper
*
4106 Sylon Blvd Hainesport, NJ 08036 www.accuthermal.com Ph: 609-326-3190
Bleed in Valve
HEPA Filter
*
Air Filtration
ATS1036
unit
With this type of system use the following baskets. Model Part # FTBLL12 ATS1023 FTBLL26 ATS1025 FTBLL27 ATS1053 FTBLL47 ATS1031
Vent outside or into the plant stack or exhaust air
Extraction Fan
*
With parts in the bath and lid on, the damper would be adjusted so fumes and smoke are pulled away from the bath and into the air filtration system. If the damper is open too much it creates a negative pressure in the bath working area resulting in significant heat and sand loss. The purpose of the Cyclone is to recover any sand pulled out and heavier deposits which can be sieved and reused. The bleed in valve is opened to cool down the exhaust air stream before entering the filtration unit.
ATS1043
Loading...