DIAGRAM #1
If the installation site has a fume
exhaust hood present then the
following components are all that is
required. IMPORTANT: the exhaust
needs to be strong enough to
completely pulls fumes from the
bath to prevent combustion.
Use the following Lid
Model Part #
FTBLL12 ATS1020
FTBLL26 ATS1020
FTBLL27 ATS1031
FTBLL47 ATS1031
4106 Sylon Blvd
Hainesport, NJ 08036
www.accuthermal.com
Ph: 609-326-3190
Fume Exhaust Hood
Customer supplied
and installed
Bath lid
Tooling to be cleaned
With this basic type of system
use the following baskets.
Model Part #
FTBLL12 ATS1022
FTBLL26 ATS1024
FTBLL27 ATS1053
FTBLL47 ATS1030
Parts basket
900.0
900.3
Fluidized
Temperature
Bath

DIAGRAM #2
The following system will extract fumes
venting them into a new stack or tie
into existing plant exhaust
ATS1033
Extraction fan
Use the following Lid
Model Part #
FTBLL12 ATS1020
FTBLL26 ATS1020
FTBLL27 ATS1031
FTBLL47 ATS1031
4106 Sylon Blvd
Hainesport, NJ 08036
www.accuthermal.com
Ph: 609-326-3190
Stack or existing
exhaust ventilation
Air damper
With this type of system
use the following baskets.
Model Part #
FTBLL12 ATS1023
FTBLL26 ATS1025
FTBLL27 ATS1053
FTBLL47 ATS1030
ATS1021
Extraction collar
Note: This collar
is not needed with
model FTBLL47
& FTBLL27
**
**
With parts in the bath and lid on, the damper would be adjusted so fumes and smoke
are pulled away from the bath and into the exhaust system. If the damper is open too
much it would create a negative pressure in the bath working area resulting in
significant heat and sand loss. The purpose of the Cyclone is to recover any sand pulled out
and heavier deposits which can be sieved and reused.
**
ATS1032
Cyclone

DIAGRAM #3
The following system will filter out
fumes and smoke in the HEPA rated
filtration system. The filtered air can be
released outside or vented into your
plant stack.
Use the following Lid
Model Part #
FTBLL12 ATS1020
FTBLL26 ATS1020
FTBLL27 ATS1031
FTBLL47 ATS1031
ATS1032
Cyclone
Air damper
*
4106 Sylon Blvd
Hainesport, NJ 08036
www.accuthermal.com
Ph: 609-326-3190
Bleed in Valve
HEPA Filter
*
Air Filtration
ATS1036
unit
With this type of system
use the following baskets.
Model Part #
FTBLL12 ATS1023
FTBLL26 ATS1025
FTBLL27 ATS1053
FTBLL47 ATS1031
Vent outside or into the plant stack or
exhaust air
Extraction Fan
*
With parts in the bath and lid on, the damper would be adjusted so fumes and smoke
are pulled away from the bath and into the air filtration system. If the damper is open
too much it creates a negative pressure in the bath working area resulting in
significant heat and sand loss. The purpose of the Cyclone is to recover any sand
pulled out and heavier deposits which can be sieved and reused. The bleed in valve is
opened to cool down the exhaust air stream before entering the filtration unit.
ATS1043