APPL I C A TIO N S
Filtering of exhaust air
from Fluidized Bath tool
cleaning and other
extrusion operations
Remove smoke, fumes,
VOC’s and other fine
particulate
Can be vented back into
the plant or outside
BEN E F I T S
Common filter sizes that
can be easily replaced by
side access panels
Oil mist impinger filters
can be washed out for
reuse
Sump base has a drain for
collection of any oil
Available in vertical or
horizontal configuration
Designed and
manufactured in USA
Air Filtration System
Captures oil mist, smoke and fumes
Easy access panels for filter replacement
Powder coat painted for long life
Common filter sizes that can be
purchased from many sources
Large 8” diameter inlet and outlet for best
air flow
Use an exhaust blower capable of 750 to
1000 cfm of flow for best results
The DCS2500 has been designed for use by
Plastic Extrusion and Injection Molding
companies to remove fine particulate,
smoke and fumes from the exhaust stream
of plant operations including tool cleaning in
Fluidized Temperature Baths. The DCS2500
does not require any power, natural gas or
continuous water supply to operate. Contact
us for technical details and drawings on how
to connect and plumb up the system.
Unique Solutions for Thermal Applications

WH A T ’ S I NC L U D ED
-Powder coat painted
cabinet and filters in each
section.
-8” OD inlet and outlet
plenums
-Instruction manual
WH A T D O I N E E D T O
RU N T H E S Y S T E M
-750 to 1000 CFM blower
that is placed on the outlet
side of the system drawing
exhaust air into the filters.
-
At least 9 feet of vertical or
horizontal space to install
the system
-We recommend
www.ductincorporated.com
for piping, transition fittings,
slide valves (dampers) and
bleed in valves.
SERVI C E S AVAILABLE
-Technical support
-Application support
-Maintenance
The DCS2500 has a relatively small footprint as
shown but is 108” long. In the horizontal
configuration it can be mounted to a wall and in
the vertical configuration it can be free standing.
It is ordered in either configuration that best suits
your space and layout considerations. Three feet
of clearance is needed on the inlet side of the
system to open the filter access panels.
Shown here is a typical
system layout and plumbing
for a Fluidized Temperature
Bath system. Other plant
operations where it is
desirable to have exhaust
air filtered can also be tied
into the system.
Call us with your
applications questions!
609-326-3190
Specifications & Ordering info
DCS2500
Overall System footprint 27”W x 27”D x 108”H
Extraction blower air flow required 750 to 1000 CFM
Maximum air inlet temperature 160°F / 70°C
Shipping weight 800 lbs
Filter Details
Oil mist impinger (2 required) Aluminum mesh, 24” x 24” x 2”
Prefilter (1 required) Merv 11, 24” x 24” x 4”
HEPA filter (1 required) 99.97%, 24” x 24” x 12”
Activated carbon canister (2 off) 24” x 24” x 8” (each canister
contains 45 lbs of granular
carbon that can be refilled)
Order code ATS1036
Warranty (powder coat painted cabinet) 1 year
Hainesport, NJ 08036 USA
Ph: 609-326-3190
Fax: 609-479-5124
Email: sales@accuthermal.com
Website: www.accuthermal.com