AccuPower IQ312 User guide

English
User Manual
Please read the manual carefully before using this charger.
We thank you that you have decided to purchase our intelligent charger.
 
Please follow the safety and care instructions in this manual, to be able to use this device efficiently and safely.
Included Delivery:
• Charger IQ312
• Power supply
• User Manual

9 120004 642820
1/6
English
User Manual
Important Notes:
Use the IQ312 charger only with Li-Ion / LiMnO2 cells with 3.6V-3.7V and NiCd,
NiMH cells with 1.2V rechargeable batteries.
With the IQ312 you can automatically charge the following types of cells:
Li-Ion:
26700, 22650, 21700, 20700, 18650, 18500, 18490, 17670, 17500, 17355,
16340 (RCR123), 14500, 10440
NiMH/NiCd: AA, AAA, A, Sub-C, C
Do not use the charger with other types of batteries (for example: Alkaline or other
Systems).
Use the charger only in dry and closed rooms with normal conditions.
If the charger is not in use, we recommend disconnecting the power cable from the
socket.
During the charging process, you should not leave the charger unattended.
Keep the batteries out of the reach of children.
Always use the right charging current for each battery. You can find the right current
in the manufacturers specification.
When new batteries are in use for the first time, it might be required that the batteries
need to be charged and discharged several times before they reach their optimum
capacity.
The charger must be used on a non-flammable base.
Heat gets produced if batteries get charged. It is very important to ensure that the
charger is placed in an incombustible area (pay attention to carpets, paper,
flammable liquids, furniture and so on).
2/6
English
User Manual
Input:
DC 12V / 3,2A
Output:
Twelve independent slots
Button Functions:
„Light On“ Button
Display:
During the charging process, the following values are shown on the display:
Battery symbol Slot number Charging current (mA) State of charge (25%, 50%, 75% und 100%)
LC Display
3/6
English
Charging function:
User Manual
The IQ312 works in a mode called „ Current Auto Set Mode “. This means, for every inserted battery, the current is set automatically. This feature allows a simple and safe use of the charger. The automatically chosen charging current depends on the chemistry the inserted battery has, regardless of its size or capacity. All twelve channels are independent, so every channel can be occupied by different batteries, that are distinguished as follows:
Type 1: NiMH, NiCd:
Please insert your batteries in your IQ312. The charger can be powered before or after inserting the batteries, it makes no difference for the functionality. After the charger recognizes the NiMH or NiCd cells, the charging process starts automatically. The current gets set to 500mA for each slot.
Type of battery Charging current per slot
- mA
NiMH, NiCd 500
Table 1: Charging current for NiMH and NiCd
After the charger has accepted the battery, the display lights up for 30s and signalizes hereby that the battery is alright and ready to charge. Also a charge-current-arrow of the according channel on the display shows that the battery is already charging. Also visible on the display, there are bars that show the actual state of charge of each channel.
Type 2: Li-Ion:
Charging Li-Ion batteries works the same as charging NiMH or NiCd batteries. You can insert your batteries before or after powering the charger. That makes no difference in functionality. Now there are two options how to choose the charging current for each battery. It depends on which slots are used. Every two adjacent slots (e.g. slot 1 and 2; slot 3 and 4; slot 5 and 6 and so on) are paired and share their power. If only one of two paired slots (e.g. slot 5 is empty and slot 6 is charging) are occupied by a Li-Ion battery, then the charging current is set to 1000mA. Otherwise if both paired slots are occupied, the charging current gets shared and every slot is sourced with 500mA.
Battery Type Charging current if one of
two paired slots is occupied
Charging current if both of
two paired slots are
occupied
- mA mA
Li-Ion 1000 500
Tabelle 2: Charging current for Li-Ion
4/6
English
User Manual
Charging has finished:
If the charging process has finished, the charger signalizes it clearly with a flashing of the display backlight three times in a row. This procedure looks the same for any type of battery. Further, the charging bars on the display become stable, that also shows that the according battery is fully charged.
„Light On“ - Button:
With the aid of the “Light On” button you can turn on the display background light by pressing the button once. If the button gets pressed and held down for a few seconds, the display background light flashes once, that signalizes the background light is now turned on permanently. If you want to turn off the background light again, you must press and hold the button again for a few seconds until the display flashes again.
Maintenance:
The chargers are maintenance free but should be cleaned sometimes. The charger should be disconnected from the power supply before cleaning. Use only soft and dry tissues (like cotton textiles) do not use any liquid.
Disclaimer:
The manufacturer and supplier are not responsible for incorrect or improper use
and the resulting consequences.
Any repair or modification that is not performed by the original supplier will void the
warranty.
The device may be used only by people who have read and understood such instructions. The information in this document are subject to change without previously pointed out. This product is not a toy. Keep out of reach of children. The reproduction of this manual or parts of it, is permitted only with written permission of
the manufacturer.
5/6
English
User Manual
Safety instructions:
Please observe the following safety instructions:
Use as described in the instructions, only NiCd, NiMH or Li-Ion batteries! The device is not approved for outdoor use. Protect it from high humidity, water, rain or
snow. Keep the device away from excessive heat and direct sunlight.
Do not dispose batteries in a fire! Do not use other than the supplied accessories. In particular, attention is drawn to use the
supplied original power adapter for the battery charger.
Disconnect the power cord from the outlet when not in use. The device should not be used if it has received a blow or damaged in any other form. Don’t use the charger for any other purposes than described in the instruction. Do not open or disassemble the unit, otherwise there is a risk for electric shock or fire.
Note on disposal:
Please inform yourself about the local collection points for electronic devices. Please check local environmental standards and do not dispose your old products with normal household waste. The charging unit may only be disposed of in waste management authorities set up collection points. The proper disposal of your old product will help the environment and health. Rechargeable batteries may not be disposed in domestic waste. Return used batteries to your dealer or to an authorised battery collecting point.
TECHNICAL SPECIFICATIONS IQ312
Input Voltage
Monitoring / Display
Display Backlight Yes
Controls One Button „easy to use“ function (easy handling).
Operating Modes Charge
Charge Method
Safety Temp. Control Charge Cutoff Max. Temperature (50°C)
Charge Voltage
Charge Current
Discharge Cut-off Voltage No discharge function available
Battery Types/Size
Battery Capacity Range
Case Material / Size Plastic / L: 240mm; W: 158mm; H: 34mm
Weight 425g for charger unit
AC Input: 100-240V (for AC Power supply); DC Input: 12V (11-14V) / 3,2A
LC display live view with backlight:
Shows the charge status, capacity, voltage, charge current,
operating time and internal resistance. Size:70mm * 25mm
CC/CV for Li-Ion batteries, Delta-peak Sensitivity for NiMH / NiCd
NiCd / NiMH: Delta peak detection Li-Ion: 4.2V/cell 500mA, 1000mA
automatically adjusted for each channel
NiCd / NiMH: AA, AAA, A, Sub-C, C Li-Ion: 26650, 22650, 21700, 20700, 18650, 18500, 18490, 17670, 17500, 17355, 16340 (RCR123), 14500, 10440 NiCd / NiMH: Min. 300 - Max. 16,000mAh Li-Ion: Min. 300 - Max.20,000mAh
AC Power supply: AC Input: 100-240V; DC Output: 12V / 3,2A
AccuPower Forschungs-, Entwicklungs- und Vertriebsgesellschaft mbH
Pirchäckerstrasse 27, A-8053 Graz, AUSTRIA Tel.: +43 (0) 316 26 29 11-10; Fax: +43 (0) 316 26 29 11-36 E-Mail: info@accupower.at Web: www.accupower.at
NOTE: Information and contents in this document are for reference purpose only. They do not constitute any warranty or representation and are subject to change without notice.
6/6
Loading...