Pure Audio Enters a New Realm
Separate Type SA-CD/CD Player Combo
DP-800/DC-801 Redefi nes the Genre
. . .
m Digital-only SA-CD/CD transport m High-rigidity, high-precision SA-CD/CD
drive m Digital processor with revolutionary SA-CD reproduction technology
MDSD m Accuphase original digital interface: HS-Link m MDS++ D/A converter
with eight DACs driven in parallel m “Ultra Jitter-Free +” PLL circuit m “Direct
Balanced Filter” with totally separate balanced and unbalanced signal paths
The DP-800/DC-801 SA-CD/CD player enters the fi eld as the desig-
nated successor to the DP-100/DC-101 model pair. The DP-800 is the
transport, featuring a newly developed, ultra-massive SA-CD/CD drive
designed for high rigidity and utmost precision. The DC-801 processor
boasts a totally new approach to digital signal handling called MDSD,
which enables straight D/A conversion of the DSD signal. Revolu-
DP-800/DC-801 connection
A single HS-Link cable carries
both the SA-CD and CD signal.
HS-Link cable
m Connection is possible to any com-
ponent with a built-in HS-Link interface or an HS-Link option board,
such as DP-100, DC-101, DC-330,
DP-85, DP-78 etc.
Analog
output
Audio
cable
㩷
Preamplifi er
Sound fi eld compensation with DG-38: analog connection examples
Connection example 1
DG-38 inserted in analog connection between preamplifi er and power amplifi er
tionary Accuphase technology paired with our famous dedication to
sonic excellence fi nally brings out everything the SA-CD format has
to offer. The two components are connected via HS-Link cable, using
Accuphase’s exclusive high-quality digital interface HS-Link. Connecting a DG-38 for sound fi eld processing in the digital domain is also
possible.
Digital recording/playback with DC-801
A digital recorder can be connected for recording/playback of
sources other than SA-CD
Coaxial cable
m The SA-CD/CD signal supplied via HS-Link
does not appear at the DIGITAL OUTPUTS
and therefore cannot be recorded digitally.
To record the CD signal from the DP-800
digitally, use a coaxial connection.
Coaxial cable
Coaxial cable
Optical fi ber cable
CD transport or other
digital component
Optical fi ber cable
Digital recorder
HS-Link cable
Line input board
For balanced connections: AI2-B1
For unbalanced connections: AI2-U1
Analog
output
Audio
cable
Sound fi eld compensation with DG-38 in digital domain
CD transport or other
digital component
Coaxial cable
HS-Link cable
Optical fi ber cable
Connect DG-38 to EXTERNAL DSP
connectors of DC-801 and set EXT
DSP button to ON, to allow sound
fi eld compensation of digital signal.
Analog
output
Audio
cable
Preamplifi er
Audio
cable
For balanced connections: AO2-B1
For unbalanced connections: AO2-U1
Connection example 2
Multi-channel system including DF-45
Analog
output
Audio
cable
HS-Link cable
Coaxial cable
Audio
cable
Line output board
Power amplifi erPreamplifi er
Preamplifi er
Audio
cable
Line input board
For balanced connections:
For unbalanced connections:
AI2-B1
AI2-U1
HS-Link cable
m Connect DC-801 and DG-38 with HS-Link
cable. The signal from all sources connected to the DIGITAL INPUTS of the DC-801
will be routed through the DG-38.
m If the DC-801 is connected to the DG-38 via
coaxial cable, the signal input via HS-Link
will not be routed through the DG-38.
Audio
cable
Audio
cable
Power amplifi er (for high frequency range)
Power amplifi er (for low frequency range)
Accuphase Exclusive Digital Interface
HS-Link: High Speed Link
HS-Link is an ultra high-quality digital audio interface developed by Accuphase using latest digital signal transmission technology. It supports send/receive verifi cation for copyright protection. The LVDS (Low Voltage Differ-
ential Signaling) principle allows a single dedicated HS-Link cable to transmit all audio data with utmost fi delity.
Capability to carry the SA-CD signal as well as conven-
n
tional digital audio formats such as CD, MD, CD-R, etc.
Transfer rate: 1923 Mbps (logical limit)
n
Transfer signal format: Low Voltage Differential
n
Signaling (LVDS) TIA/EIA-644
Send/receive clock fully synchronized
n
Full bidirectional capability with simultaneous send/receive
n
Full security capability with send/receive verifi cation
n
Cable type: Shielded twisted pair 8-conductor OFC cable
n
(equivalent to TIA/EIA-568A CAT.5)
Sampling frequencies
32 kHz, 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
(16 to 24 bit, 2-channel PCM)
176.4 kHz, 192 kHz (24 bit, 2-channel PCM)
2.8224 MHz (1 bit 2-channel DSD)
HS-Link cable (supplied with DP-800)
Front panel
n
Rear panel
n
DP-800
Front panel
n
Rear panel
n
DC-801
DP-800 and DC-801 connected
n
with HS-Link cable
HS-Link block diagram
MDS++ D/A Converter with eight circuits operating in parallel
The D/A converter that forms part of the MDSD type moving-average fi lter circuit is an MDS++ D/A
converter with an amazing eight circuits operating in parallel, ensuring the utmost in accuracy and sound
quality.
MDS (Multiple Delta Sigma) is an innovative approach that employs several delta sigma type converters
in a parallel confi guration for greatly improved accuracy. Combining the output signal from individual
converters causes mutual cancellation of conversion errors, resulting in a notable improvement in all
relevant aspects of conversion performance: accuracy, S/N ratio, dynamic range, linearity, and THD.
Digital
input
Signal
Conversion error
Note the ratio between signal
and conversion error. In the
MDS output, the error is very
small in relation to the signal.
(Signal)
(Conversion
error)
MDS output
MDS type D/A converter principle
n
Eight delta sigma converters
n
Ultra Jitter-Free + PLL circuit
The output of any D/A converter contains so-called aliasing noise in the very high frequen-
DAI signal input
The operation of the D/A
converter must be synchronized with the digital input
signal. For this purpose, a
phase-locked loop (PLL)
circuit is used to extract the
master clock which is used
as system reference. In the
DC-801, this important task
is handled by a further improved circuit called Ultra
Jitter-Free + PLL.
Preamble
detector
Phase
compa-
rator
Divider
Optimized
clock divi-
sion ratio
Master clock output
Loop
fi lter
Preamble signal
pulse distortion
removed
cy range. An analog fi lter designed to remove that noise is therefore always required. The
fi lter circuitry in the DC-801 uses 5-pole Butterworth analog fi lters with extremely fl at fre-
quency response in the passband. In order to prevent unwanted interaction, the low-pass
fi lter confi guration is completely separate for the balanced and unbalanced signal paths.
(Normal phase output)
(Reverse phase output)
8 DACs driven in
parallel
Block diagram of MDS++ principle
n
I (Current) - V (Voltage) converter
Current summing
“Direct Balanced Filter” circuit
Voltage
summing
DAC output
Subtraction
SA-CD/CD indicator
Track display
Index display
Time display
Repeat indicator
REPEAT / 1 / A-B
Program indicator
Power switch
SA-CD/CD button
MODE button
ENTER button
Remarks
This product is available in versions for 120/230 V AC. Make sure that the voltage shown on the rear panel matches the AC line voltage in your area.
The shape of the AC inlet and plug of the supplied power cord depends on the voltage rating and destination country.
DP-800 Guaranteed Specifi cations
m Compatible disc formats 2-channel SA-CD
CD
m Data read principle Non-contact optical pickup
m Laser diode wavelength SA-CD: 650 nm
CD: 780 nm
m Digital outputs
HS-Link Connector type: RJ-45
Suitable cable: Dedicated HS-Link
COAXIAL Format: IEC 60958
m Power requirements AC120 V/230 V (Voltage as
m Power consumption 18 W
m Maximum Dimensions
Width 477 mm (18-5/16")
Height 156 mm (5-7/8")
Depth 394 mm (15-5/8")
m Mass 26.6 kg (58.6 lbs) net
32.0 kg (70.5 lbs) in shipping carton
indicated on rear panel)
50/60 Hz
Supplied with DP-800
m AC power cord
m HS-Link cable (HDL-15)
m Remote Commander RC-100
m Cleaning cloth
m
Specifi cations and design subject to change without notice for improvements.
Disc tray
Disc tray open/close button
Play button
Pause button
Track search buttons
BACK, NEXT
Stop button
Digital output connectors
HS-LINK (SA-CD/CD signal)
COAXIAL (CD signal only)
AC power connector
cable
Supplied with DC-801
m AC power cord
m Audio cable with plugs (1 meter)
m Cleaning cloth
DC-801 Guaranteed Specifi cations
m Digital inputs
HS-Link Connector type: RJ-45
Suitable cable:
COAXIAL Format: IEC 60958
OPTICAL Format: JEITA CP-1212
BALANCED Digital balanced cable: characteristic imped-
Sampling frequencies 32 kHz, 44.1 kHz, 48 kHz,
HS-Link only 176.4 kHz, 192 kHz (16 to 24 bit,
m Digital outputs
COAXIAL Format: IEC 60958
OPTICAL Format: JEITA CP-1212
m D/A converter MDSD principle (DSD signal)
MDS++ principle (PCM signal)
m Frequency response 0.5–50,000 Hz +0, –3 dB
Total harmonic distortion
m
88.2 kHz, 96 kHz
(16 to 24 bit, 2-channel PCM)
2-channel PCM)
2.8224 MHz (1 bit 2-channel DSD)
0.0006% (20 to 20,000 Hz)
http://www.accuphase.com
Alphanumeric input display
Function indicators
LOCK, MDSD, EXT DSP
Output level display
Power switch
Input selector buttons
OPTICAL 1, 2, COAXIAL 1, 2, 3
BALANCED, HS-LINK
Output level control buttons
DOWN, UP
EXT DSP button
[Guaranteed specifi cations are measured according to JEITA standard CP-2402A)
m Signal-to-noise ratio 117 dB
Dedicated HS-Link cable
ance 110 ohms
m Dynamic range 117 dB (24-bit input, low-pass fi lter off)
m Channel separation 113 dB (20 to 20,000 Hz)
m Output voltage and impedance
BALANCED 2.5 V 50 ohms, balanced XLR type
UNBALANCED 2.5 V 50 ohms, RCA phono jack
m Output level control 0 dB to –80 dB (digital)
m Power requirements
AC120 V/230 V (Voltage as indicated
m Power consumption 22 W
m Maximum Dimensions
Width 477 mm (18-5/16")
Height 156 mm (5-7/8")
Depth 393 mm (15-1/2")
m Mass 22.3 kg (49.2 lbs) net
28.0 kg (61.7 lbs) in shipping carton
Optional cables
m HS-Link cable HDL-15 (1.5 m)
Digital input connectors
HS-LINK, BALANCED
COAXIAL 1, 2, 3, OPTICAL 1, 2
Analog output connectors
UNBALANCED, BALANCED
EXTERNAL DSP connectors
INPUTS (HS-LINK, COAXIAL)
OUTPUTS (HS-LINK, COAXIAL)
DIGITAL output connectors
COAXIAL, OPTICAL
AC power connector
on rear panel)
50/60 Hz
3 m, 5 m, 7.5 m, 10 m also available
L0605Y PRINTED IN JAPAN 851-0162-00 (AD1)