AccuMac AM1210 User Manual

Page 1
AM1210 Type S Reference Standard
Thermocouple User’s Guide
Page 2
AM1210 Type S Reference Standard Thermocouple
User’s Guide
1/4
Table of Contents
1.1 Introduction......................................................................................................... 2
1.2 Specifications...................................................................................................... 2
Before you start ---- Warnings & Cautions
Warnings: Follow these guidelines to avoid personal injury:
1. Only use this instrument in the manufacture specified temperature range.
2. The transition junction and the lead wires of this instrument can become hot when it is used to measure high temperatures for extended periods of time.
3. DO NOT submerge the transition junction when taking measurement.
4. DO NOT use this instrument to measure the temperature of any hazardous live component.
5. Follow all other safety guidelines listed in this user’s guide.
Cautions: Follow these guidelines to avoid possible damage to the instrument:
1. Avoid mechanical shocks. DO NOT drop or slam the probe in any way. This
will cause damage to the probe internally and affect its calibration and accuracy.
2. Read Section entitled “Care and Handling Guidelines” before removing the
thermocouple from the shipping box. Incorrect handling can damage the thermocouple and void the warranty.
3. Keep the shipping container in case it is necessary to ship the thermocouple.
Incorrect packaging of the thermocouple for shipment can cause irreparable damage.
4. Calibration equipment should only be used by trained personnel.
Page 3
AM1210 Type S Reference Standard Thermocouple
User’s Guide
2/4
1 Introduction and Specifications
1.1 Introduction
AM1210 Type S Reference Standard Thermocoupleis constructed using reference grade Platinum and Platinum vs. 10% Rhodium alloys. It covers a temperature range of 0 °C to 1300 °C with short term stability of 0.2 °C all the way to Freezing Point of Copper (1084.62 °C). It is commonly used as reference standard to calibrate industrial thermocouples. All thermocouple wires and parts are specially cleaned and annealed before assembly. Every AM1210 thermocouple is fully annealed and tested again to meet the tolerance criteria as specified in the table below.
1.2 Specifications
Temperature Range
0°C to 1300°C
Type
Type S: Platinum/10 % Rhodium vs. platinum
Long Term Drift
±0.6°C at 1084.62 °C after 1 year typical usage
Tolerance (mV)
E(tCu)=10.575±0.015 E(tAl)=5.860+0.37(E(tCu)-10.575)±0.005 E(tZn)=3.447+0.18(E(tCu)-10.575) ±0.005
Short Term Stability
±0.2°C at 1084.62 °C
Diameter of thermocouple wire
0.5 mm
Sheath Material
Quartz or Alumina
Sheath Dimensions
OD: 6 mm; Length: 500 mm
External Lead Wire
S type thermocouple wire, 500 mm
Protective Carrying Case
Included
2 Care and Handling Guidelines
1. DO NOT subject the thermocouple to any physical shocks and vibrations.
a. When not using the thermocouple, keep it in a place
that’s not prone to drop, slam, bang, vibration or other
Page 4
AM1210 Type S Reference Standard Thermocouple
User’s Guide
3/4
strong physical contacts. Use a protective box or a carrying case whenever possible.
b. When shipping the thermocouple, use protective box
and other protective packaging materials to minimize mechanical shocks as much as possible.
c. When using dry blocks, make sure the well diameter is
appropriate to allow the thermocouple move up and down smoothly.
2. DO NOT subject the thermocouple to any contaminations. Keep the thermocouple as clean as possible.
a. DO NOT over heat. Do not use the thermocouple above
the manufacture specified temperature range.
3 Limited Warranty & Limitation of Liability
Each product from AccuMac Corporation is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is 1 year for the thermocouple. The warranty period begins on the date of the shipment. Parts, product repairs, and services are warranted for 90 days. The warranty extends only to the original buyer or end-user customer of an AccuMac authorized reseller. The warranty will not extended to products that have been misused, altered, neglected, or damaged by accident or abnormal conditions of operation or handling.
To obtain warranty service, contact AccuMac Corporation at:
3150 N Arizona Ave STE 103 Chandler, AZ 85225 USA Tel: (480)634-0603 Email: Sales@accumac.com
Loading...