Model Numbers
PLUS2 Models:
FF6L / FF7L / FF28LWH / FF511L / FF521BL / FFAR24L / SCR600L / FF590SSHH /
FFAR10 / FFAR12W / FFAR121SS / PLUS2 Series
All-refrigerators with automatic defrost or frost-free operation
ACF48W / VT65ML / FS603 / FS407L / FS30L / FS24L PLUS2 Series
All-freezers
CM411L / CP351/ CT66L / S19LWH / CP133 PLUS2 Series
Refrigerator-Freezers
SP6DS / SP6DSSTB / SP6DS2D PLUS2 Series
Drawer refrigerators
PLUS2 all-refrigerators include digital thermostats, internal fans, and NIST calibrated
thermometers.
PLUS2 refrigerator-freezers include internal fans (in the refrigerator compartment) and
NIST calibrated thermometers.
PLUS2 all-freezers include NIST calibrated thermometers.
PRO Models:
FF6 / FF7 / FF28LWH / FF511L / FF521BL / FFAR24L / FF28LWH / SCR600L / FFAR10
/ FFAR12W / FFAR121SS PRO Series
All-refrigerators with automatic defrost or frost-free operation
VT65M / FS603 / FS407L / FS30L / FS24L PRO Series
All-freezers with manual defrost operation
PRO all-refrigerators include digital thermostats, internal fans, and probe holes. PLUS2 all-freezers include probe holes for user-provided monitoring equipment.
MED Models:
FF511L / FF521BL / FF7L / SCR610BL / SCR1156 MED Series
All-refrigerators with automatic defrost or frost-free operation
VT65ML / FS407L / FS30L / FS24L MED Series
All-freezers with manual defrost operation
MED all-refrigerators include digital thermostats, internal fans, and NIST calibrated
temperature alarms.
PLUS2 all-freezers and refrigerator-freezers include NIST calibrated temperature alarms.
2
Table of Contents
Model Numbers ......................................................................... 1
Appliance Safety ....................................................................... 3
Proper disposal of an old appliance ..................................... 3
Installation Instructions ........................................................... 4
Key Eject lock ....................................................................... 4
Location Requirements ...................................................... 5 – 6
Location ................................................................................ 5
Recommended grounding method ....................................... 5
Leveling your appliance ....................................................... 6
When using the appliance .................................................... 6
Energy-saving tips ................................................................ 6
Appliance Care .................................................................... 7 – 8
Defrosting ............................................................................. 7
Cleaning the appliance ......................................................... 7
Changing the light bulb ........................................................ 8
Loss of power ....................................................................... 8
Moving the appliance ........................................................... 8
Temperature Selection and Monitoring .......................... 9 – 13
Manual (dial) thermostat ...................................................... 9
Digital thermostat ............................................................... 10
Traceable thermometer (PLUS2 models) ........................... 11
Probe hole port (PRO models) ............................................ 11
Traceable thermometer/alarm (MED models) ............. 12 – 13
Keypad Lock ........................................................................... 14
Operation of Specific Models ................................................ 15
Troubleshooting & Best Practices ................................. 16 – 17
Notes ....................................................................................... 18
Limited Warranty .................................................................... 19
3
Appliance Safety
Your safety and the safety of others are very important to us. We have provided many important safety messages in this manual and on your
appliance. Always read and obey all safety messages. You can be seriously injured or even killed if you don’t follow instructions. Safety messages will tell you what the potential hazard is, how to reduce the
chance of injury, and what can happen if the instructions are not followed.
Plug into a grounded 3-prong outlet. Do not remove ground prong, nor use a 3/2 adapter. Do not use an extension cord. Use care not to plug into outlets controlled by wall switches. Disconnect power before servicing. After servicing, replace all parts and panels before operating. Use nonflammable cleaners. Keep flammable materials and vapors, such as gasoline, away from
appliances.
Use two or more people to move and install appliance.
NOTE: Drawer refrigerators are provided with anti-tip brackets. Always install
prior to use.
Proper disposal of an old appliance:
Old appliances can represent a suffocation hazard to children.
Remove doors from your old appliance. Leave shelves in place. If an old appliance contains refrigerants, it must be recycled by a licensed service
or disposal company.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock or injury
when using your appliance, follow these basic precautions:
4
Installation Instructions
Excessive Weight Hazard !
Use two or more people to move and install your appliance.
Failure to do so can result in back or other injury.
ALLOW APPLIANCE TO SIT UPRIGHT FOR 24 HOURS BEFORE TURNING ON, TO ALLOW THE COMPRESSOR LUBRICANT TO DRAIN.
1. Remove packaging materials.
2. Remove tape and glue residue from surfaces before turning on the appliance. Rub a small amount of liquid dish soap over the adhesive with your fingers. Rinse with warm water and dry.
3. Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your appliance.
4. When Moving Your Appliance: Your appliance is heavy. When moving the appliance for cleaning or service, be sure to protect the floor. Always pull the appliance straight out when moving it. Do not wiggle or “walk” the appliance when trying to move it because floor damage can occur.
5. Clean Before Using: After you remove all of the packaging materials, clean the inside of your appliance before using it. See cleaning instructions in Appliance Care.
6. Some upright models have leveling legs. Level as necessary for best operation.
7. If your appliance has casters, after moving into place, lock the brakes on those casters supplied with brakes. Always unlock before moving the appliance for cleaning.
Key Eject lock (some models):
To lock or unlock the appliance, you must hold the key in the lock while turning. The lock is spring-loaded, so the key cannot be left in the lock.
If the key is lost, contact your dealer or SUMMIT APPLIANCE for a replacement. Always give the model and serial number of your appliance when requesting a replacement key. Keys for most models can be ordered online at
www.summitappliance.com/support
5
Location Requirements
Keep flammable materials and vapors, such as gasoline, away from appliances. Failure to do so can result in fire, explosion or death.
Location:
IMPORTANT: Do not install the appliance near an oven, radiator, or other heat source, nor in a location where the temperature will fall below 40°F (5°C). Do not place in direct sunlight.
Check the strength of the floor before installing your appliance. It should hold the weight of a fully loaded appliance. Allow at least 4” (10 cm) of airspace at the top and on both sides of the appliance and also 4” between the back of the appliance and the wall. If the appliance is going to be placed next to a wall, leave extra space on the hinge side so the door can open wider than its width.
NOTE: Allow 4” (10 cm) clearance at the top and sides and a ¼” (0.64 cm)
clearance between appliances. IF YOUR MODEL HAS THE LETTERS “BI”
IN THE SUFFIX, IT IS DESIGNED FOR BUILT-IN USE AND REQUIRES ONLY
MINIMAL
CLEARANCES EXCEPT AT THE BACK WHERE AT LEAST 2” OF CLEARANCE SHOULD BE ALLOWED. ALL FF590, SCR610BL, AND ACF48W MODELS ARE ALSO BUILT-IN CAPABLE.
Electrical Shock Hazard
Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord.
Failure to follow these instructions can result in fire, electrical shock or death.
Recommended grounding method:
A 115 Volt (AC only) 60 Hz grounded electrical supply with a 15- or 20- amp fuse or circuit breaker is required. It is recommended that a separate circuit serving only your appliance be provided. Use outlets that cannot be turned off by a switch or pull chain. Do not use an extension cord.
6
Leveling your appliance (some upright models):
Locate the two front leveling legs that may be taped among the packing materials. (In many models these legs are already mounted into the underside of the appliance.)
1. Screw these legs into the front holes on the bottom of the appliance. The back of the appliance rests on two fixed supports. (Built-in models also have rear level legs that can provide more precise leveling).
2. Adjust the front legs just enough to lift the cabinet up off the floor. Note: If your model is equipped with front rollers, the front legs should be lowered
enough to lift the rollers off the floor to ensure the appliance does not roll forward when the door is opened.
3. Place a leveling tool on top of the appliance, first side to side, then front to back. Turn leg counter-clockwise to raise a corner. Turn leg clockwise to lower a corner.
4. Repeat Step 3 until appliance is level.
5. After appliance is fully loaded, recheck with level as in Step 3.
6. If your appliance is equipped with casters, the two front casters have brakes to
prevent rolling. Keep brakes locked, and unlock for moving only.
When using the appliance:
In order to ensure proper temperature, you need to permit proper airflow in the appliance. Do not block off any air vents. If the vents are blocked, airflow will be hindered, and temperature and moisture problems may occur. Always position contents to allow some airflow between shelves or baskets.
Allow the appliance to cool at least 6 to 8 hours before adding contents. Allow 24 hours for temperature to stabilize.
NOTE: When the appliance is first started, the compressor will run constantly until the
appliance is cooled. It may take 6 to 8 hours (or longer), depending on room temperature and the number of times the appliance door is opened. After the appliance has cooled, the compressor will turn on and off as needed to keep the appliance at the proper temperature.
For optimum temperature performance, it is recommended that this unit be at least 30% full during use. If you are only using this unit to store small loads, we recommend adding some water bottles or freezer packs to ensure temperature stability.
The outside of your appliance may feel warm. This is normal. The appliance’s design
and main function is to remove heat from packages and air space inside the appliance. The heat is transferred to the room air, making the outside of the appliance feel warm. (In some models the condenser that gets warm is just inside the side walls,
making these walls warm to the touch.)
ENERGY-SAVING TIPS
The more airflow provided around an appliance, the less energy it will use. If your appliance requires manual defrosting, keep ice build-up to less than 1/2". Keep doors open a minimum of time, and shut securely.
7
Appliance Care
Defrosting:
Refrigerator models listed in this manual defrost automatically. However, freezer models require manual defrosting. Before defrosting the unit, remove the contents of the freezer, then set the thermostat to OFF (the compressor will stop working). Leave the door open until ice and frost are completely melted. To speed up defrosting, you can place a container of warm water (about 125°F) into the cabinet. Soak up the melt water with clean toweling or a sponge and be sure the interior is dry before turning the thermostat back to its normal setting.
NOTE: It is not advisable to heat the interior of the freezer directly with hot water or
a hair dryer while defrosting since this can deform the cabinet interior.
NEVER USE A METAL OBJECT TO REMOVE ICE FROM THE
REAR WALL. IF NEEDED, USE A PLASTIC ICE SCRAPER.
Cleaning the appliance:
NOTE: To prevent the buildup of odors, clean the appliance about once a month. Follow the procedure below for cleaning:
1. Disconnect from power.
2. Remove any parts that can be taken out of the cabinet, such as drawers.
3. Using a clean sponge or soft cloth, hand wash, rinse and dry removable parts and
interior surfaces thoroughly. Use a mild detergent in warm water. DO NOT use abrasive or harsh cleansers such as window sprays, scouring cleansers, flammable fluids, cleaning waxes, concentrated detergents, bleaches or cleansers containing petroleum products. DO NOT use harsh cleaning tools such as paper towels or scouring pads, as these can scratch or damage the surfaces of the refrigerator.
4. For stainless steel and painted metal exterior surfaces, use a clean sponge or soft
cloth and a mild detergent in warm water. DO NOT use abrasive or harsh cleaners, or cleaners containing chlorine, as these can scratch or damage the material. Using a soft cloth, dry thoroughly.
5. To help with removing odors, you can use a mixture of warm water and baking
soda (2 tbs to 1 qt of water) to wash the interior walls.
6. After cleaning, replace all of the parts that were removed from the appliance.
7. The condenser coils, located on the back or behind the base grille, should also be
cleaned regularly. This may be as often as every other month. Cleaning the condenser coils can help reduce how much energy the appliance uses. When the condenser coils are dusty or dirty, use a vacuum cleaner with an extension attachment.
8. After cleaning the appliance, plug in or reconnect power.
NOTE: For CSS Models (completely stainless steel), only use cleaners
especially made for stainless steel.
8
Changing the light
bulb (some models only):
NOTE: Not all appliance bulbs will fit your appliance. Be sure to replace the bulb
with one of the same size, shape, base size and wattage. You can purchase bulbs from www.summitappliance.com/support
1. Unplug appliance or disconnect power.
2. Remove the light shield. Most models do not require tools.
3. Replace the light bulb with an appliance bulb of the same wattage. Replacement LED bulbs are available from our parts department.
4. Replace the light shield.
5. Plug in appliance or reconnect power.
Loss of power:
In the event of power loss, unplug the appliance. Once power is restored, allow 30 minutes for the refrigeration system to equalize. During this time, keep the door closed as much as possible.
Remember: A full appliance stays cold longer than a partially filled one.
Moving the appliance:
1. Remove stored items and tape shelves, drawers and trays in place.
2. Unplug the appliance.
3. Clean it thoroughly.
4. Tape the appliance shut and tape the electrical cord to the cabinet.
When you get the appliance to its new location, refer to the Installation Instructions and Temperature Selection sections for information on installation and setting the controls.
9
Temperature Selection and Monitoring
YOUR APPLIANCE MAY HAVE A MECHANICAL (DIAL) OR DIGITAL THERMOSTAT.
DIAL INSTRUCTIONS ARE BELOW. DIGITAL INSTRUCTIONS ARE ON PAGE 10.
Manual (dial) thermostat (on some models):
Your appliance may be controlled with a thermostat knob located inside or in the rear of the unit, towards the right-hand corner. Turn the knob clockwise from the STOP (0) position toward the higher numbers for colder temperatures.
Setting the Temperature:
Higher settings on the knob (higher numbers) mean lower temperatures
(colder) in all compartments of the appliance. The temperature inside a refrigerator may even drop below 32°F. Use higher thermostat settings only when required or recommended. When the ambient temperature is normal, we recommend a medium setting.
Changes of the ambient temperature affect temperature in the interior of the
appliance, so keep this in mind when choosing the setting of the thermostat dial.
At STOP (0) position, the appliance does not operate (the cooling system is
switched off), but the power supply is not interrupted.
The temperatures in the refrigerator and freezer compartments also depend
on how often you open the door.
In all small refrigerators and freezers without interior fans, temperatures are coldest near the bottom, and occasionally near the rear. Place contents accordingly.
For optimum temperature performance, it is recommended that your unit be at least 30% full during use. If you are only using this unit to store small loads, we recommend adding some water bottles or freezer packs to ensure temperature stability.
10
Temperature Selection & Monitoring, cont’d
Digital Thermostat (standard on all-refrigerators, ACF48W models, and VT65MLADA models):
If you find it necessary to change the temperature setting for your digital thermostat, please refer to the following instructions.
How to Adjust the Temperature:
To see the SET POINT:
The default display for your digital thermostat is the internal cabinet temperature. To view the unit’s set point, push and immediately release the SET key. The display will flash, showing the set point value. If no other actions are taken in 6 seconds, the display will revert to the internal air temperature.
To change the SET POINT:
While the set point value is blinking, press the UP or DOWN arrow to change the set point to your desired temperature. Press the SET button again to exit the adjustment. The display will revert to the internal air temperature.
PLEASE NOTE: the temperature displayed on the digital thermostat is the internal air temperature. Your alarm/thermometer (installed on the left in the control panel) provides a temperature readout based on the buffered probe in order to better simulate the temperature of what is actually stored inside the unit (as opposed to the air temperature itself). As a result, these readings may not always display the same temperature reading.
NOTE: The minimum and maximum range of your thermostat is preset and
locked so it cannot easily be accidentally moved outside of the recommended temperature ranges.
Note:
Details may vary from image.
11
Traceable thermometer (PLUS2 models):
This digital thermometer simultaneously displays maximum, minimum and current temperatures. The Max/Min feature monitors and stores the highest and lowest readings since the battery was inserted or since the RESET button was last pressed.
The temperature sensor, or probe, is enclosed in a glycol-filled bottle that is inserted into the location to be monitored, such as inside a refrigerator or freezer. The thermometer itself can be attached to the door of the unit with the magnet on the back, or it can be placed on a convenient table or shelf.
Power to the Traceable Thermometer is supplied with one AAA lithium battery. When it is inserted correctly, all segments of the LCD display are temporarily activated. When the battery needs to be replaced, a battery symbol will flash on the display.
The temperature display can be switched between Celsius (°C) and Fahrenheit (°F) with a push of the °C/°F button. The display will alternate between refrigerator (probe) temperature and room temperature when you press the ROOM/FRIDGE button. Press
RESET to clear the Max/Min temperature record.
See instruction pamphlet for more information about the Traceable Thermometer.
Probe Hole/Access Port (PRO Series):
PRO series refrigerators and freezers include a 3/8” probe hole to allow users to
install their own monitoring equipment. The probe hole is usually located in the upper part of the rear cabinet. If you are having difficulty locating the hole, refer to the product’s brochure on our website.
If installing your own thermometer, alarm, or data logger, we recommend using a device with a buffered temperature probe and placing the probe towards the center of the unit. This will help provide a temperature reading closest to the contents being stored inside your refrigerator or freezer. If your unit includes a fixed shelf with a probe holder (see details on page 12), we recommend placing the probe inside the extra slot in this shelf.
12
Traceable Thermometer/Alarm (MED Models):
Alarm style varies by product Every MED unit is equipped with a NIST-calibrated Traceable Thermometer/Alarm
that simultaneously displays minimum, maximum, and current interior temperatures and provides a visual and audible signal when the temperature inside the unit falls outside the set temperature range.
NOTE ABOUT CALIBRATION: All MED units ship with a two-year certificate of calibration in the alarm/thermometer box that comes inside your unit. Keep this
certificate stored safely for your records. Accucold offers re-calibration services through their ISO 17025:2005 certified calibration laboratory. It is recommended to have your probe re-calibrated every two years (or one year, depending on your state’s health department guidelines). For more information on how to have your device re­calibrated, contact us at calibration@summitappliance.com.
The temperature sensor, or probe, is enclosed in a glycol-filled bottle that is stored inside your unit in a special shelving compartment.
In some units, the center shelf is fixed in place and cannot be removed (see image). This is because the glycol-filled bottle that contains the temperature sensors for your alarm and thermometer is best stored in this location. The center of your refrigerator or freezer will provide the most accurate temperature readings. For proper temperature monitoring, keep the bottle in place and do not remove this shelf.
Thermometer/alarm instructions continue on page 13man
13
Thermometer/alarm instructions (cont’d):
Function of Controls:
MODE/RESET Key: Press ONCE to reset Max/Min temperature record. When the unit
is sounding an alarm, press ONCE to turn off the beeping sound.
HIGH/LOW Key: Press ONCE to display high alarm setting. Press TWICE to display
low alarm setting. Press THREE TIMES to display current temperature reading.
ºF/ºC Key: Press this button to alternate the temperature display scale between
Fahrenheit (ºF) and Celsius (ºC).
Battery Installation: Remove battery compartment cover located on the rear of the
unit and remove insulation strip from battery compartment. Following the polarity (+/-) diagram in the battery compartment, install the battery. Replace the battery cover. The unit will beep and all segments of the LCD will be activated.
Programming the Alarms:
The thermometer displays the internal temperature of the unit being monitored, as well as the maximum and minimum temperatures reached. The maximum and minimum readings reflect the highest and lowest temperatures since the battery was inserted or since the MODE/RESET key was last pressed. If the temperature rises above or falls below the set temperature range, the alarm will sound. By default, the high alarm temperature setting is 8°C (46.4°F) and the low alarm temperature setting is 2°C (35.6°F). To reset these limits, follow these instructions:
High Alarm Temperature Setting: Press the HIGH/LOW key ONCE, then press
MODE/RESET to enter the High Alarm temperature setting mode. Use the Up and Down arrows to adjust the temperature accordingly. Press MODE/RESET once again to confirm the setting.
Low Alarm Temperature Setting: Press the HIGH/LOW key TWICE, then press
MODE/RESET to enter the Low Alarm temperature setting mode. Use the Up and Down arrows to adjust the temperature accordingly. Press MODE/RESET ONCE to confirm the setting.
By default, the low and high alarms should be audible. To turn alarms on/off: Audible High Alarm Setting: To make sure the high alarm is audible, press HIGH/LOW
key ONCE (to activate HI-SET on the screen). Then press the ALERT ON/OFF key ONCE to activate the HIGH-ALARM beeping sound. Press again to deactivate.
Audible Low Alarm Setting: To make sure that the low temperature alarm is audible,
press the HIGH/LOW key TWICE to activate LOW-SET on the screen. Then press the ALERT ON/OFF key ONCE to activate the LO-ALARM beeping sound. Press again to deactivate.
NOTE: Set high and low alarm temperature limits above and below the refrigerator/
freezer operating temperature to prevent false alarms.
NOTE: For an activated high alarm and low alarm buzzer, the display should
indicate HI-ALARM and LO-ALARM (see illustration on previous page).
More details about the features and usage of the Traceable Thermometer/Alarm can be found in the User Manual accompanying the unit.
14
Keypad Lock (optional on most models)
Factory-set default password: The factory-set default password is 0123. If the default
password is lost, press the key (located inside the battery box) for
30 seconds, then wait for the warning sound which signifies the factory-set default password has been restored.
To set the password: While door is open, press the key (located inside the battery box) until it jingles, enter the 0123 password, then # within 10 seconds to confirm. Enter your password (1-16 digits), then press # again to confirm. A total of 10 passwords can be set.
NOTE: Each password starts with a number from 0 to 9 in order. The first password starting
with 0 is the default password. For example, use 1xxx, then 2xxx etc. for 10 users.
Changing password: While the door is open, press the key (located inside the battery box) until it jingles, enter the old password and press # within 10 seconds to confirm. Enter the new password, then press # to confirm. NOTE: The first digit cannot be changed.
To open the door: While the door is closed, press the START/END key, enter the password, then press START/END again to confirm.
To lock door manually: Press #. Function setting of automatic lock: Setting of the auto-lock time: Press the key
(inside the battery box), enter a number (any number between 10 and 99), then press # to confirm. The auto-lock time can be set between 10 and 99 seconds after opening the door. If the time is set less than 10 seconds, the door will not lock automatically, only manually.
Deleting the door-opening passwords: Press the START/END key, enter default password followed by 0000, then press # and all the door-opening passwords will be deleted except for the default password.
NOTE: To access the battery box you need to remove only the two small screws on the top
and bottom of that cover. Do not remove the 4 screws holding the keypad and cover to the appliance door.
15
Operation of Specific Models
FF6L, FF7L, FF28LWH, FF511L, FF521BL, FF590SSHH, FFAR24L, FFAR10, FFAR12W, FFAR121SS, SCR600L PLUS2, PRO, & MED Series; SP6DS2D, SP6DS, SP6DSSTB PLUS2 Series only; SCR610BL, SCR1156 MED Series only
These models are all-refrigerators (no freezer compartment) with automatic defrost. All have cold plates on the rear wall, and the coldest spots in the refrigerator will be in the rear and toward the bottom. All have interior fans to promote even cooling. In the rear bottom above the step, there is a drain line to allow defrost water to exit the refrigerator. Keep this drain line clear, or icing inside the refrigerator will occur. FF7, FF511L, FFAR10, and SCR series models have lights that are not door-activated, and are controlled either by a rocker switch on the top right or a light switch inside. The light inside these units will stay on until switched off manually. While LED lighting will not generate heat, it is not recommended to leave the light on for long periods of time.
ACF48WPLUS2 Series
These frost-free all-freezers can be built-in or free-standing. They do not require defrosting and have a digital thermostat and a lock. At the top of the unit is a cooling system that uses a fan to provide cold air. For best operation, do not block the air flow with contents.
FS24L, FS30L, FS603, FS407L, VT65ML PLUS2, PRO, & MED Series
These are manual defrost all-freezers. No internal fans are present, and ice will build up along the cooling coils. Periodically defrost the ice (recommended when the ice level reaches a thickness of 1/4 to 1/2 inch). NEVER USE A METAL INSTRUMENT as you can damage the cooling coils, which will void your warranty and often cannot be repaired. To defrost, disconnect from the power supply, empty the contents, provide a tray in the bottom to collect water, and use a hairdryer or other source of warm air to melt the ice (or leave the door open and the power off for 24 to 48 hours).
CP351 & CT66L PLUS2 Series
These models are cycle defrost refrigerator-freezers. The freezers are designed to operate at 0°F (-18°C), suitable for medical or laboratory uses. These models have dual evaporators to maintain separate temperatures in the freezer and refrigerator. Defrost the freezer carefully, as directed above for manual defrost. The refrigerator section operates in the normal range (35 to 45°F, or 2 to 7°C) and defrosts automatically.
CM411L, S19LWH, CP133 PLUS2 Series
These models are manual defrost refrigerator-freezers. The freezers in these models are designed to operate at 25°F (-4°C) to keep ice frozen, and not for medication or products needing colder temperatures. Defrost carefully, following directions above. The refrigerator section will operate in the normal range (35 to 45°F, or 2 to 7°C) and is suitable for most refrigerated products.
NOTE: FF590SSHH, ACF48W, SCR610BL, drawer units, and models with BI in the model
number are designed for built-in installation and need very little clearance on the sides and above the units. All other models require at least 4 inches of airflow on the sides and above the units. All models, including built-in units, operate best when 2 inches is provided between the rear wall and the back of the unit.
16
Troubleshooting
Try these solutions first to avoid the cost of an unnecessary service call.
PROBLEM: The appliance is not operating.
Is the power supply cord unplugged? Plug into a grounded 3-prong outlet.  Has a fuse blown or a circuit breaker been tripped? Replace the fuse or reset
the circuit.
Is the thermostat incorrectly set? See How to Adjust the Temperature on
page 10.
PROBLEM: The motor is constantly running, or running too much
Is it hotter than usual where the appliance is located? At normal temperatures,
the motor will typically run between 40% and 80% of the time. The motor will run even longer when the unit is in an unusually warm environment.
Has a large number of items been added to the appliance? The more that is
added, the longer it will take for the unit to cool down. During this process, the motor will run longer.
Is the door frequently opened? Warm air entering the appliance causes the
motor to run longer. Keep the door closed as much as possible.
Is thermostat set correctly? See How to Adjust the Temperature on page 10.
Is the door completely closed? Push the door firmly shut.
Are the condenser coils dirty? This prevents proper air transfer, and causes the
motor to work harder. Clean the condenser coils. See Cleaning the Appliance on page 7, and refer to #7.
Does the unit have proper clearance? Models with “BI” in their name require 2”
of rear clearance and minimal clearance on the sides and top. All other units require at least 4” of clearance on all sides for proper operation.
PROBLEM: The temperature in the cabinet is too warm
Have you just added a large number of items to the appliance? This will warm
the interior of the unit until it is able to cool down to the correct temperature.
Is thermostat set correctly? See How to Adjust the Temperature on page 10.
PROBLEM: There is excessive moisture inside the appliance
Is the door opened frequently? If so, humidity from the room will enter the
appliance and cause moisture to build up. This will happen even more if the air in the room is very humid.
PROBLEM: The door is hard to open
Is the door gasket dirty or sticky? Clean the gasket and the surfaces that it
touches. Rub a thin coat of paraffin wax on the gasket after cleaning.
17
Best Practices
Maintenance of the Refrigerator or Freezer
Report breakdowns immediately and arrange for alternative
monitored storage for vaccines while the appliance is being repaired.
Regularly check the door seals to ensure a good seal is
maintained. Replace the seals if they are damaged or cold air is leaking from the appliance.
Defrost the appliance regularly, if required, to prevent build-up of
ice which will result in unstable temperatures. Regular defrosting also aids in efficient functioning of your appliance.
If there are exposed coils on the back of the appliance, keep
them clean and dust-free to improve operating efficiency.
Checking the Door Seal
To check that the vaccine storage unit door is sealing properly:
1. Place a thin paper strip against the cabinet front.
2. Close the door.
3. Pull the paper strip. If it moves easily or falls away by itself, the door and the rubber-like seal need to be adjusted.
4. Check all the way around the door. Pay particular attention to the corners.
5. Based on this assessment, if a problem with the door seal or hinges is suspected, contact a trained repair technician.
Checking If the Thermometer Works
A slight variation in temperature is often seen from one thermometer reading to another, even when the vaccine storage unit thermostat is set at a particular temperature. This is normal. If the thermometer reading does not fluctuate at all over several readings, temporarily remove the thermometer from the storage unit and place it outside the unit at room temperature. Check whether the temperature reading rises. If no change in the temperature reading occurs, the thermometer is faulty and needs to be replaced.
18
Notes
19
Limited Warranty
ONE YEAR LIMITED WARRANTY FOR APPLIANCE
Within the 48 contiguous United States, for one year from the date of purchase, when this appliance is operated and maintained according to instructions attached to or furnished with the product, warrantor will pay for factory-specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a designated service company. Outside the 48 states, all parts are warranted for one year from manufacturing defects. Plastic parts, shelves and cabinets are warranted to be manufactured to commercially acceptable standards, and are not covered from damage during handling or breakage.
5-YEAR COMPRESSOR WARRANTY
1. The compressor is covered for 5 years.
2. Replacement does not include labor.
ITEMS WARRANTOR WILL NOT PAY FOR:
1. Service calls to correct the installation of your appliance, to instruct you how to use your appliance, to replace or
repair fuses or to correct wiring or plumbing.
2. Service calls to repair or replace appliance light bulbs or broken glass shelves. Consumable parts (such as filters)
are excluded from warranty coverage.
3. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation
not in accordance with electrical or plumbing codes, or use of products not approved by warrantor.
4. Replacement parts or repair labor costs for units operated outside the United States.
5. Repairs to parts or systems resulting from unauthorized modifications made to the appliance.
6. The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in
accordance with published installation instructions.
DISCLAIMER OF IMPLIED WARRANTIES – LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
PRODUCT REPAIR AS PROVIDED HEREIN. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR. WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE.
FELIX STORCH, INC.
770 Garrison Avenue Bronx, New York 10474 Phone: (718) 893-3900 Fax: (844) 478-8799 www.accucold.com
For parts and accessory ordering,
troubleshooting and helpful hints,
visit:www.summitappliance.com/support
January 2018
WARNING: This product can expose you to chemicals including Nickel (Metallic) which is known to the State of California to cause cancer.
For more information go to www.P65Warnings.ca.gov
Note: Nickel is a component in all stainless steel and some other metal components.
Loading...