QUICK REFERENCE GUIDE
Quick Reference Guide
QRG for 0 482930 1001(03) 2007-05
Roche Diagnos tics Gmb H
D-6829 8 Mannhe im, Germa ny
www.acc u-chek.c om
ACCU-C HEK und A CCU-CHEK GO
are tr ademarks of Roch e.
This Quick Reference Guide does not
replace the comprehensive User’s Manual
for your Accu-Chek Go meter. Please be
sure to read the safety notices contained
in the Instructions for use.
1.
2.
![](/html/ca/ca71/ca712451fd52b0af0da18ae7e2453f674e3add99d12a0351bcae216d251041f6/bg2.png)
Beep tone
Press and hold down
(for more than 3 seconds)
Time &
Date
Time-and-
date format
Hours
Minutes
Time
Date
Year
Month
Day
Press briefly
(turn off
)
On
(On1)
Off
(OFF)
Acoustic Mode
(On2)
Press briefly
(turn off
)
Target range
Off
On
Value
Lower limit
(LL)
Off
On
Value
Upper limit
(LH)
Press briefly
(turn off
)
Alarm clock function
Press briefly
(turn off
)
Press briefly
(turn off
)
Turning on the meter
and starting Quick
set-up
Off
On
Hours
Minutes
AL1
AL2
AL3
AL4
Top and sides
Þ button: turn on or off, start a set-up to
change settings, save entries
Liquid crystal display (LCD)
< and > buttons: change settings (decre-
ment and increment value, respectively),
retrieve results, request averages
Test strip guide – this is where you insert the
test strip
Measurement optics cover
Test strip ejector
Code chip
Infrared port for downloading results to a PC,
for instance
Bottom
Code chip
Code chip slot
Type plate
Battery compartment
Battery (type CR 2032)
1 Set-up
2 When an average is displayed: number of days
covered
3 LH or LL: target range setting (set-up)
4 Alarm clock function turned on.
Flashing: optical signal during alarm
5 Test or averaging in progress
6 Unit of measurement for BG result
7 Flag indicating special result
8 Flashing: cue to allow test strip to draw up
blood
9 Flashing: cue to insert test strip
10 Test strips are past their expiry date
11 Code number display.
Flashing: code chip is missing
12 Target range setting (set-up).
Flashing: result is outside the target range
13 Flag indicating quality control
14 Flashing: temperature is/was outside the
permitted range
15 Beep tone or Acoustic Mode is turned on
16 Flashing: battery is running low
17 When an average is displayed: number of
results included
18 Memory, averages or results download
19 Follows time in 12-hour format
20 Display messages
Code chip is missing.
In memory: no results in memory, averaging
not possible or result erased
Alarm setting (set-up)
Flashing: latest result being erased
End of set-up, self-test following test or
download complete
In Quick set-up: group selected
Result >600 mg/dL (33.3 mmol/L)
Result <10 mg/dL (0.6 mmol/L)
Results download
Error messages
Test strip inserted incorrectly, test strip
bent/moved, strong electromagnetic
field
Code chip from another system, meter
cannot read code chip, code chip defec
-
tive, code chip removed during test
Measurement optics dirty, test strip
drew up blood too soon, test strip bent/
moved, used strip inserted, test strip
past its expiry date, new test strip inser
ted too soon after last test (while End
was showing)
Test strip drew up too little blood, test
strip drew up blood too soon, test strip
bent/moved, battery empty, meter error,
strong electromagnetic field
Temperature too low or too high to test.
Quick set-up: Changing settings
Þ press and held down for more than 3 seconds at
anytime = save, exit set-up and turn off
< > change with < or >
press briefly = save or scroll
17
18
16
15
14
13
7
6
5
4
20
3
2
1
11 10 9 8
19
12