ABUS FU2938 User Manual [en, de, fr, it, pl]

FU2938
Kompaktalarmierung
Kompaktalarmierung
[D] Installationsanleitung .......................................... 1
Compact Alarm
[UK] Installation Guide ............................................ 12
Système d’alarme compact
[FR] Instructions d’installation ................................ 22
Sistema di allarme compatto
[IT] Istruzioni per l'installazione .............................. 32
Compacte Sirene + Flitser
[NL] Installatieaanwijzingen .................................... 42
Kompaktalarmering
[DK] Installations Guide .......................................... 52
Kompaktowy moduł alarmowy
[PL] Instrukcja instalacji .......................................... 62
1
Hinweise Um eine Manipulation der Kompaktalarmierung zu vermeiden, sollte das
Produkt außerhalb des Handbereiches (mindestens 3 Meter Montagehöhe) montiert werden.
Bitte beachten Sie außerdem die lokalen gesetzlichen Bestimmungen. In einigen europäischen Ländern ist der Einsatz von Sirenen im Außenbereich verboten oder die maximale Alarmdauer ist reduziert. Im Zweifelsfall informieren Sie sich bei Ihren lokalen Behörden.
Durch unsachgemäße oder unsaubere Installationsarbeiten kann es zu Störungen oder Fehlfunktionen kommen. Lesen Sie sich daher diese Anleitung genau durch. Berücksichtigen Sie die Angaben zur Schutzart und achten Sie bei der Installation der Anlage auf die genaue Bezeichnung der verwendeten Leitungen und Komponenten.
Hauptmerkmale
mikroprozessorgesteuerte Kompaktalarmierung (Sirene mit Blitzlicht) geeignet für Innen- und Außenmontage
stabiles wetterfestes Gehäuse Innen- und Außengehäuse aus verzinktem und lackiertem Stahlblech Schutz gegen Sabotage, Abriss, Zerstörung der Blitzleuchte und
Kabelbeschädigung Alarmdauer der Sirene 3min optionaler 12V / 1200mAh Akku extrem Lautstark 118dB(A) @ 1m in zwei Varianten nutzbar (als Standard- oder als Funkausführung)
2
Beschreibung des Aufbaus
1 Bohrlöcher für Wandbefestigung 2 Kabelzuführung 3 Xenonblitz 4 Piezosirenen 5 Platz für Akku 6 Sabotagekontakt Deckel 7 Sabotagekontakt Wand 8 Diagnose LED 1 9 Diagnose LED 2 10 Diagnose LED 3 Akku 11 Diagnose LED 4 Akkuladung 12 Jumper für Diagnose LED’s
Wahlschalter zur Ansteuerung der Sirene
Steuersign al Sirene
Steuersign
3
Aktivierungsmethode Die Aktivierung der Kompaktalarmierung erfolgt wahlweise:
1. durch ein negatives Eingangssignal (0V DC) an [Strob Trig], bzw. [Siren Trig]
oder durch Ansteuerung über den RJ11 Stecker
2. durch eine interne Sabotage
3. durch eine externe Sabotage (Kabeldurchtrennung)
Sabotagemodus Die Kompaktalarmierung erkennt zwei Sabotagearten und aktiviert die Alarmierung automatisch.
Interner Sabotagekontakt Wird der interne Sabotagekontakt ausgelöst (Öffnen des Deckels, Abriss von der Wand), aktiviert die Kompaktalarmierung automatisch den Alarm über Blitz und Sirene. Der Sabotagealarm wird gleichzeitig am Sabotageausgang ausgegeben. Beim Rücksetzen des Sabotagekontakts wird auch der Alarm gestoppt. Bei der Funkvariante wird das Sabotagesignal über das Funk-Universalmodul an die Alarmzentrale geschickt.
Durchtrennen der Kabelzuführung Beim Durchtrennen der Kabelzuführung werden Sirene und Blitz nach 6 Stunden für 30s aktiviert. In der Funkvariante wird die Sabotage über das Funk-Universalmodul an die Alarmzentrale gemeldet.
Signalisierung Die Kompaktalarmierung signalisiert je nach ausgelöstem Alarmeingang über Sirene und/oder Blitz. Nach einer Stunde reduziert die Kompaktalarmierung die Blitzfrequenz von 1Hz auf 1/8Hz.
Bei Ausfall der Versorgungsspannung werden automatisch Sirene und Blitz nach 6 Stunden für 30s aktiviert.
Alarmdauer Die Alarmierung endet immer, wenn der Alarmgrund nicht mehr vorliegt und somit die Eingänge nicht mehr angesteuert werden. Bei anliegendem Steuersignal wird die Sirene jedoch nach Ablauf der maximalen Alarmzeit (3 Minuten) gestoppt. Das Blitzlicht wird erst mit dem Rücksetzen des Alarms beendet.
4
Installation der Kompaktalarmierung (Funk- und Standard-Variante)
1. Nehmen Sie die Kompaktalarmierung aus der Verpackung. Öffnen Sie das Außengehäuse und zeichnen Sie die vier Bohrlöcher für die Wandbefestigung sowie ein Bohrloch für die Kabelzuführung an.
2. Bohren Sie die entsprechenden Bohrlöcher und das Loch für die Kabelzuführung.
3. Führen Sie nun von hinten das Kabel durch die Kabelöffnung in die Kompaktalarmierung.
4. Schrauben Sie die Kompaktalarmierung an die Wand.
5. Achten Sie beim Festschrauben darauf, dass der rückseitige Sabotagekontakt eingedrückt ist.
6. Verbinden Sie nun die Leitungen des Anschlusskabels mit den Anschlussklemmen (Drahtvariante) wie in der Anschlussübersicht beschrieben, bzw. stecken Sie den RJ-11 Stecker (Funkvariante) ein.
7. Optional können Sie zwischen [+12V DC] und [Siren Trig], sowie zwischen[+12 DC] und [Strobe Trig] jeweils einen Widerstand 1kOhm schalten, um im Ruhezustand ein
definiertes Potential an den Steuereingängen zu erhalten. Diese Beschaltung reduziert Störeinflüsse auf der Zuleitung und hilft somit unbeabsichtigtes Auslösen der Alarmierung zu vermeiden.
8. Verbinden Sie den Akku mit den entsprechenden Klemmen. Es ertönt ein kurzer Signalton.
9. Setzen Sie den Jumper (12), je nach Position der Steckbrücke sind die Diagnose-LED’s aktiv oder deaktiv, und schließen Sie das Gehäuse.
Anmerkung: Beim Schließen des Gehäusedeckels ertönt ein langer Ton. Danach führt
die Kompaktalarmierung einen Selbsttest durch. Beim erfolgreichen Abschluss des Tests beginnen die LEDs wechselseitig zu blinken. Ein Öffnen des Gehäuses führt nun zu einem Sabotagealarm.
5
Verdrahtung der Kompaktalarmierung FU2938 (Standard) Anschluss des Akkus
Im Auslieferungszustand ist der Akku nicht angeschlossen. Befestigen Sie die schwarze Leitung am Minuspol des Akkus und die rote Leitung am Pluspol des Akkus.
Anschluss der Versorgungsspannung Verbinden Sie die Eingänge [+12V] und [GND] mit der 12V DC Spannungsversorgung.
Anschluss von Sirene und Blitz
1. Sirene und Blitz werden jeweils durch das Anlegen eines 0V
Massepotentials aktiviert.
2. Für die Ansteuerung des Blitzes verbinden Sie den Eingang [Strobe
Trig] mit einem Ausgang Ihrer Alarmzentrale. Da der Blitz über das Anlegen eines Massepotentials aktiviert wird, können Sie den Blitz auch über einen Transistorausgang Ihrer Alarmzentrale ansteuern, der im Alarmfall auf 0V schaltet.
3. Für die Ansteuerung der Sirene verbinden Sie den Eingang [Siren Trig]
mit einem Ausgang Ihrer Alarmzentrale. Da die Sirene über das Anlegen eines Massepotentials aktiviert wird, können Sie die Sirene auch über einen Transistorausgang Ihrer Alarmzentrale ansteuern, der im Alarmfall auf 0V schaltet.
4. Anmerkung: Da die Kompaktalarmierung über eine automatische
Abschaltung der akustischen Alarmierung verfügt, können [Strob Trig] und [Siren Trig] auch über einen Ausgang der Alarmzentrale angesteuert werden.
Visuelle Scharfschaltquittierung Um eine optische Signalisierung der Scharfschaltung zu ermöglichen wird der Blitz 3 – 5 mal aktiviert, wenn der Ausgang Ihrer Alarmzentrale die Eigenschaft „Aktiv Quittierung“ besitzt.
Anschluss des Sabotageausgangs der Kompaktalarmierung Verbinden Sie den Ausgang [Tamper] mit der Sabotagelinie Ihrer Alarmzentrale.
Anschluss des Akkustörungsausgangs der Kompaktalarmierung Verbinden Sie den Ausgang [BATT] mit einer Zone Ihrer Alarmzentrale.
Anmerkung Verwenden Sie ausschließlich abgeschirmte und geerdete Leitungen (AZ6360 oder AZ6361).
6
Verdrahtung der Kompaktalarmierung FU2938 (Funkvariante)
1. Führen Sie das Anschlusskabel vom Funk-Universalmodul mit dem RJ­11 Stecker rückseitig in das Gehäuse ein.
2. Stecken Sie den RJ-11 Stecker in die auf der Hauptplatine vorgesehene Buchse.
3. Setzen Sie den Jumper (12), je nach Position der Steckbrücke sind
die Diagnose-LED’s aktiv oder deaktiv.
4. Weitere Einstellungen sind nicht vorzunehmen.
7
Beschreibung der Anschlüsse
Steuersign al Sirene
Steuersign
8
Anschlussübersicht FU2938 (Standard)
Battery +
Rote Leitung zum Akku
Battery -
Schwarze Leitung zum Akku
Klemmleiste
+12V (1)
+12V DC Spannungsversorgung
GND (2)
0V DC Spannungsversorgung
Strobe Trig (3)
Blitzansteuerung (mit 0V DC im Alarmfall)
Siren Trig (4)
Sirenenansteuerung (mit 0V DC im Alarmfall)
Tamper NC/NO (5/6)
Sabotage-Relaisausgang potentialfrei NC=Normalzustand NO= Sabotage
Batt NC/NO (7/8)
Akkustörungs-Relaisausgang potentialfrei NC=Normalzustand NO= Akkustörung
Battery +
Rote Leitung zum Akku
Battery -
Schwarze Leitung zum Akku
RJ-11 Buchse
PIN 1
Akkustörungs-Transistorausgang +12V = Normalzustand 0V = kein Akku angeschlossen oder Akkufehler
PIN 2
+12V DC Spannungsversorgung (wird die Spg.-versorgung nicht innerhalb von 6h wiederhergestellt, werden Sirene + Blitz für 30s aktiviert)
PIN 3
0V DC Spannungsversorgung
PIN 4
Sabotage-Transistorausgang 0V = Normalzustand offen / hochohmig = Sabotage
PIN 5
Blitzansteuerung 0V DC im Alarmfall (Blitz ist aktiv solange 0V DC Signal anliegt)
PIN 6
Sirenenansteuerung 0V im Alarmfall (Sirene ist aktiv solange 0V DC Signal anliegt, aber nur für max. 3 min)
Klemmleiste
RJ-11 Buchse
1
PIN 2
2
PIN 3
3
PIN 5
4
PIN 6
Anschlussübersicht FU2938 (Funkvariante)
Verbundene Anschlüsse von Klemmleiste und RJ-11 Buchse
9
Fehlersuche
LED Anzeige
Bedeutung
Lösung
LED’s blinken abwechselnd einmal pro Sekunde
Normaler Betriebsmodus
LED 1 blinkt einmal pro Sekunde
Sabotage, eine oder beide Sabotagekontakte offen
Überprüfen Sie die Montage LED 2 blinkt einmal pro Sekunde
Keine Betriebsspannung angelegt
Überprüfen Sie die Verdrahtung und die Funktion der Betriebsspannungsversorgung
Rote LED 3 auf der Hauptplatine leuchtet nicht
1) Akku defekt
2) Kein Akku angeschlossen
1) Überprüfen Sie die Akkuspannung und Verdrahtung des Akkus
Rote LED 4 auf der Hauptplatine leuchtet nicht
1) Akku wird nicht geladen
2) Akku geladen
1) Kontrollieren Sie die Höhe der Betriebsspannung (13,5V)
2) Überprüfen Sie die Akkuspannung
10
Technische Daten
Spannungsversorgung
12V DC nominal
Notstromversorgt
optional
Empfohlener Akku
12V, 1200mAh, BT2012, SLA Typ
Stromaufnahme Standby
50mA
Maximale Stromaufnahme
430mA (Sirene 350mA, Blitz 80mA)
Sabotageüberwacht
Wand-Deckelkontakt und Kabel
Sirene
118dB (A) @ 1m
Blitz
Xenon-Blitzleuchte
Max. Alarmdauer
3 min
Blitzzyklen
1 Blitz/s 1 Blitz/8s (nach 1h)
Schutzart
IP34
Betriebstemperatur
-25°C bis +55°C
Maße (HxBxT)
315 x 200 x 50 mm
Material
Stahl, lackiert
Gehäusefarbe
weiß
Gewicht (ohne Akku)
2.450g
Lieferumfang
Kompaktalarmierung, Installationsanleitung
Der Hersteller behält sich vor technische Änderungen ohne Vorankündigung durchzuführen.
11
Notes To prevent manipulation of the compact alarm, install the product out of
arm’s reach (at least 3 meters high). Additionally, please take local legislation into consideration. In some
European countries, the use of sirens externally is forbidden, or the maximum alarm duration is restricted. In case of doubt, ask your local authorities for information.
Improper or careless installation work may lead to faults or malfunctioning. You should therefore read these instructions carefully. Observe the protection type specifications and follow the installation instructions for the lines and components used precisely.
Main features
Microprocessor-controlled compact alarm (siren with strobe light) Suitable for indoor and outdoor installation
Stable, weatherproof casing Interior and exterior housing made of galvanised, painted steel
plate
Protection again sabotage, unauthorised removal, destruction of
flashlight and cable damage Alarm duration of siren: 3 min. Optional 12V/1200mAh rechargeable battery Extremely loud: 118dB(A)@1m. Usable in two versions (standard or radio version).
12
Description of construction
1 Drill holes for wall fixing 2 Cable feed 3 Xenon strobe 4 Piezo sirens 5 Space for rechargeable battery 6 Tamper contact (cover) 7 Tamper contact (wall) 8 Diagnostics, LED 1 9 Diagnostics, LED 2 10 Diagnostics, LED 3, battery 11 Diagnostics, LED 4, battery charge 12 Jumper for diagnostic LEDs
Wahlschalter zur Ansteuerung
Steuersign al Sirene
13
Method of activation The compact alarm system can be activated in different ways as follows:
1. By a negative input signal (0V DC) at [Strob Trig] or [Siren Trig] or by a signal at the RJ11 plug
2. By internal tampering
3. By external tampering (cable severance)
Tamper mode The compact alarm detects two types of tampering and activates the alarm automatically.
Internal tampering contact If the internal tampering contact is triggered (by opening the cover, unauthorised removal from the wall), the compact alarm automatically triggers the alarm via the strobe and the siren. The tampering alarm is simultaneously issued at the tamper output. When the tamper contact is reset, the alarm stops. In the radio version, the tamper signal is sent to the alarm centre via the radio universal module.
Cable severance If cables are severed, the siren and strobe are activated for 30 seconds after 6 hours. In the radio version, the tampering is reported to the alarm centre via the radio universal module.
Signalling The compact alarm signals an alarm via the siren and/or the strobe light, depending on the alarm input triggered. After one hour, the compact alarm reduces the strobe frequency from 1Hz to 1/8Hz.
If the power supply fails, the siren and strobe are automatically activated for 30 seconds after 6 hours.
Alarm duration The alarm always ends if the reasons for the alarm no longer exists and the inputs are therefore no longer addressed. However, if a control signal is received, the siren stops following expiry of the maximum alarm time (3 minutes). The strobe light does not switch off until the alarm is reset.
14
Installing the compact alarm (radio and standard versions)
1. Remove the compact alarm from the packaging. Open the external casing and use it to mark the four drill holes for the wall fixings and a hole for the cable feed.
2. Drill the holes accordingly and the hole for the supply cable.
3. Now pull the cable from behind through the cable hole into the compact alarm.
4. Screw the compact alarm to the wall.
5. When tightening the screws, make sure that the rear sabotage contact is correctly pressed into place.
6. Connect the individual wires of the connection cable to the clamps (wired version) as described in the connector overview, or plug in the RJ11 plug (radio version).
7. Optionally, you can insert a 1kOhm resistor between [+12V DC] and [Siren Trig], as well as between [+12 DC] and [Strobe Trig] in order to obtain a defined potential at the control inputs for the idle state. This wiring method reduces disturbances to the feed lines, thus helping to avoid accidental alarm triggering.
8. Connect the battery to the respective clamps. A short signal tone sounds.
9. Set the jumper (12) to the right position for the diagnostic LEDs (active or inactive), and close the casing.
Note: When you close the casing lid, a long tone sounds. The compact alarm
then runs a self-test. If the self-test is successful, the LEDs start to flash alternately. Opening the casing now triggers a tamper alarm.
15
Wiring of compact alarm FU2938 (Standard) Battery connection
When delivered, the internal battery is not connected. Connect the black lead to the minus pole of the battery and red lead to the plus pole of the battery.
Connecting the power supply Connect the [+12V] and [GND] inputs with the 12V DC voltage supply.
Connecting alarm siren + strobe
1. The siren and the strobe are each activated by the presence of a 0V ground potential.
2. To trigger the strobe, connect the [Strobe Trig] input with an output of your alarm centre. Since the strobe is activated by connecting a ground potential, you can also control the strobe via a transistor output of your alarm centre that switches to 0V in case of an alarm.
3. To trigger the siren, connect the [Siren Trig] input with an output of your alarm centre. Since the siren is activated by connecting a ground potential, you can also control the siren via a transistor output of your alarm centre that switches to 0V in case of an alarm.
4. Note: Since the compact alarm has an automatic deactivation of the acoustic alarm, [Strob Trig] and [Siren Trig] can also be addressed via an output of the alarm centre.
Visual set acknowledgement To enable optical signalling of alarm setting, the strobe is activated 3–5 times if the output of your alarm centre has the “active acknowledgement” property.
Connecting the tamper output of the compact alarm Connect the [Tamper] output with the tamper line of your alarm centre.
Connecting the battery fault output of the compact alarm Connect the [BATT] output with a zone of your alarm centre.
Remarks Use only shielded and grounded cables (AZ6360 or AZ6361).
16
Wiring of compact alarm FU2938 (radio version)
1. Pull the connecting cable of the radio universal model with the RJ-11 plug through the back of the casing.
2. Insert the RJ-11 plug into the socket provided on the main board.
3. Set the jumper (12) to the right position for the diagnostic LEDs (active or inactive).
4. No other settings are required.
17
Connections
Steuersign al Sirene
Steuersign
18
Connector overview FU2938 (Standard)
Battery +
Red lead to battery
Battery -
Black lead to battery
Clamp strip
+12V (1)
+12V DC voltage supply
GND (2)
0V DC voltage supply
Strobe Trig (3)
Strobe control (with 0V DC in case of alarm)
Siren Trig (4)
Siren control (with 0V DC in case of alarm)
Tamper NC/NO (5/6)
Tamper relay output potential-free NC=normal state (normal closed) NO=tamper (normal open)
Batt NC/NO (7/8)
Battery fault relay output, potential-free NC=normal state (normal closed) NO=battery fault
Battery +
Red lead to battery
Battery -
Black lead to battery
RJ-11 socket
PIN 1
Battery fault transistor output +12V = normal state 0V = no battery connected or Battery fault
PIN 2
+12V DC voltage supply (If the voltage supply is not restored with 6h, the siren + strobe are activated for 30s.)
PIN 3
0V DC voltage supply
PIN 4
Tamper transistor output 0V = normal state open / high impedance = tamper
PIN 5
Strobe control 0V DC in case of alarm (strobe is active when 0V DC signal is present)
PIN 6
Siren address 0V in event of alarm (siren is active is 0V DC signal is present, but only for max. 3 min)
Clamp strip
RJ-11 socket
1
PIN 2
2
PIN 3
3
PIN 5
4
PIN 6
Connector overview FU2938 (radio version)
Connected lines of connector clamp strip and RJ-11 socket
19
Troubleshooting
LED display
Meaning
Solution
LEDs flash alternately once a second
Normal operating mode
LED 1 flashes once a second
Tamper, one or both tamper contacts open
Check the installation
LED 2 flashes once a second
No operating voltage connected
Check the wiring and the functioning of the operating voltage supply
The red LED 3 on the main board does not light.
1) Battery defective
2) No battery connected
1) Check the battery voltage and the battery connection
The red LED 4 on the main board does not light.
1) Battery not charged
2) Battery charged.
1) Check the operating voltage (13.5V)
2) Check the battery voltage.
20
Technical data
Voltage supply
12V DC nominal
Standby
optional
Rechargeable battery recommended
12V, 1200mAh, BT2012, SLA type Standby power consumption
50mA
Maximum power consumption
430mA (Siren 350mA, strobe 80mA)
Tamper-monitored
Wall cover contact and cable
Siren
118dB (A) @ 1m
Strobe
Xenon strobe light
Max. alarm duration
3 min
Flash cycles
1 flash/second 1 flash/8s (after 1h)
Protection type
IP34
Ambient operating temperature
-25°C to +55°C
Dimensions (HxWxD)
315 x 200 x 50 mm
Material
Steel, painted
Cabinet colour
white
Weight (without battery)
2,450g
Scope of delivery
Compact alarm, installation instructions
The manufacturer reserves the right to make technical modifications without prior notice.
21
Indications
Pour éviter une manipulation du système d’alarme compact, le produit ne
peut pas être monté à portée de la main (au moins sur une hauteur de 3 mètres).
Respectez les conventions légales locales. Dans plusieurs pays
européens, l’installation de sirènes à l’extérieur n’est pas autorisée ou la durée maximale de l’alarme est réduite. En cas de doute, informez-vous
auprès de vos autorités locales. Des erreurs et des dysfonctionnements peuvent se produire, si des travaux
inappropriés ou malpropres d’installation se sont réalisés. Lisez
attentivement les instructions. Méfiez-vous des indications concernant la protection et de la désignation des conduites et des components utilisés lors de l’installation.
Caractéristiques principales
Système d’alarme compact conduit par un microprocesseur (Sirène
avec flash) Pour montage à l’intérieur ou extérieur Boîtier stable résistant Boîtier interne et externe en tôle d’acier zinguée et vernie Protection contre sabotage, démolition, destruction des feux
clignoteurs et endommagement des câbles Durée d’alarme de la sirène 3 min. Accumulateur optionnel 12V / 1200mAh Bruit extrême de sirène 118dB(A) @ 1m Utile en deux variantes (comme type standard ou comme type radio)
22