The Type T units are designed for the global market and are the best choice when size and cost are of concern. This is
our most popular and complete offering of industrial control transformers, and includes the following features:
• Type T transformers are designed with the various temperature classes:
50–150 VA with a 55° C temperature rise, 105° C insulation
200–350 VA with a 80° C temperature rise, 130° C insulation
500–5000 VA with a 115° C temperature rise, 180° C insulation
Square D manufactures a wide variety of voltage combinations for control transformers. The voltage combinations are
expressed as “Voltage Codes” and these codes are embedded within the catalog number of the transformer. Standard
codes are listed, if the voltage combination you require is not listed, call your Square D Distributor for assistance.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 2
www.SquareD.com
For the most up-to-date information
Key to Price Column
Headings
Voltage Code
Primary Voltages
Key for Dimensions & Accessory
Secondary Voltages
D
A
F
Figure 1
D
A
F
Figure 2
D
A
F
Figure 3
B
C
E
B
C
E
B
C
E
Industrial Control Transformers
Class 9070
As part of the Type T designs are MultiTap units having a variety of primary voltages on just one transformer. Our
Universal Control Transformer will provide 120 V, or near 120, power from all common primary voltages: 208 to 600 V,
and is listed as voltage code D50.
Type T MultiTap
UL/
CSA/
CE VA Type
NOM
VA
5050 T50$ 59.$ 59.$162.$ 59.$ 59.$ 99.$ 59.$162.
7575 T7562.62.164.62.62.107.62.164.
100 100 T10065.65.174.65.65.110.65.174.
150 150 T15086.86.243.86.86.115.86.243.
200 200 T200111.111.242.111.111.131.111.242.
250 160 T250117.117.245.117.117.143.117.245.
300 200 T300137.137.256.137.137.156.137.256.
350 250 T350143.143.297.143.143.161.143.297.
500 300 T500160.160.300.160.160.206.160.300.
750 500 T750223.223.331.223.223.239.223.a331.a
1000 630 T1000263.263.423.263.263.313.263.a423.a
a See Control Transformer Catalog: 9070CT9901 for Dimensions different than Digest.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TRANSFORMERS
12
Page 3
Industrial Control Transformers
Class 9070
The Type TF units are the Type T units with factory installed primary and secondary fusing. Fuse blocks are rated for
D
A
F
B
30 amp, and accept 1-1/2 x 13/32 fuses. The Primary fuse blocks are designed for rejection style fuses, requiring
customer to use 200,000 AIC rated fuses.
Type TF: Factory Installed Primary and Secondary Fuse Blocks
25 VA. . .. . .33.093.004.003.842.002.504.20.20 x .382.9
. . .. . .25 VA34.003.434.004.802.002.504.20.20 X .483.9
50 VA25 VA. . .33.093.004.003.842.002.504.20.20 x .382.9
. . .. . .50 VA34.193.434.254.992.382.814.45.20 X .484.4
75 VA50 VA. . .33.343.384.254.092.382.814.45.20 X .484.2
. . .75 VA. . .33.593.754.554.342.883.134.75.20 x .385.9
. . .. . .75 VA34.883.754.555.682.883.134.75.20 x .387.6
100 VA. . .. . .33.343.384.254.092.382.814.45.20 X .484.2
. . .. . .100 VA34.883.754.555.682.883.134.75.20 x .387.6
150 VA100 VA. . .33.593.754.554.342.883.134.75.20 x .385.9
200 VA150 VA. . .33.593.754.554.342.883.134.75.20 x .385.9
250 VA. . .150 VA35.253.754.556.052.883.134.75.20 x .387.5
300 VA200 VA200 VA34.704.505.105.502.563.755.30.20 x .388.9
350 VA250 VA250 VA35.094.505.105.893.003.755.30.20 x .3810.9
. . .300 VA. . .35.094.505.105.893.003.755.30.20 x .3810.9
. . .. . .300 VA35.464.505.106.263.563.755.30.20 x .3812.3
500 VA350 VA. . .35.464.505.106.263.563.755.30.20 x .3812.3
. . .. . .350 VA35.464.505.106.263.563.755.30.20 x .3812.3
750 VA500 VA500 VA35.665.255.736.463.434.385.93.28 X .5611.4
1000 VA750 VA750 VA36.045.255.736.844.314.385.93.28 X .5621.0
1500 VA1000 VA1000 VA35.817.067.466.614.135.817.66.28 X .5634.4
2000 VA1500 VA1500 VA37.047.067.467.844.565.817.66.28 X .5647.4
c Dimensions with FINGERSAFE® covers installed.
d Dimensions with fuse pullers installed.
www.SquareD.com
For the most up-to-date information
D1
240 X 480
120
I
FigureABCDcEFGdSlot
D2
240 x 480
24
I
D3
208
120
D5
600
I
120
I
D20
208/230/460
115
II
D23
120/240
24
I
Weight
(lbs)
A
F
TRANSFORMERS
FileFile
Listing
12
UL E61239
LR37055,
CSA
Guide 184-N-90
12-16
B
traditional materials and manufacturing techniques. When exceptional regulation and very low temperature rise are an
absolute necessity, choose the Type EO units. Type EO transformers are designed 25 VA to 5000 VA with 55°C rise.
The Type EO are designed with exceptional voltage regulation. These control transformers are constructed using
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 4
www.SquareD.com
For the most up-to-date information
Industrial Control Transformers
Accessories
Class 9070
The Type T control transformers offer multiple field installable accessories:
FINGERSAFE
Type
FSC1 T25–T200 T25–T150 N/A2 covers per kit $6.8010$68.
FSC2 T250–T5000 T250–T5000 N/A2 covers per kit 9.301093.
FSC23 N/AN/AT25–T5000 2 covers per kit 9.501095.
a Kits must be ordered separately. Also supplied in bulk packages of 100 individual covers. Add
“B” to Type number (available only on FSC1B and FSC2B).
®
Covers (not supplied with unit)
Type Accessory Keya
IIIIII, IV
Separate NEMA Type 1 Enclosures for Transformers
Class 9991 TypeFor Use With
UE7EO1, EO17, T50
LG1
SDG4EO51, EO61, T750, T1000, EO71
Note: User must drill mounting holes. See pages 14-105 & 14-106 for dimensions.
Note: Jumpers are supplied with voltage codes that require them. If additional kits are required,
order per above chart.
Type Accessory Key
IIIIII, IV
Description
Two jumpers
per bag
Minimum order
of 50 kits
Price
Order
Qty.
Order
Price
Each
$1.70 50$85.
Fuse Pullers (use on TF and FB accessory)
Catalog
9070FP1$10.2010$102.
Price
Each
Order
Qty.
Order
Price
Field Installed Fuse Options
Primary and Secondary Fusing
Type
FB3A 25–200 25–150N/A
FB3B 250–2000 200–2000 25–2000
Type Accessory Key
IIIIII, IV
Description
Three pole fuse block for
primary and secondary
fusing, accomodates 11/2" x 13/32" midget
fuse (2 rejection and 1
non-rejection)
Three pole fuse block for
primary and secondary
fusing, accomodates
1-1/2" x 13/32" midget
fuse (2 rejection and
1 non-rejection)
Price
Order
Qty.
Order
Price
Each
$27.301$27.30
27.30127.30
Primary Fusing
Type
FB2A 25–20025–150N/A
FB2B 250–2000 200–2000 25–2000
Type Accessory Key
IIIIII, IV
Description
Two pole fuse block for
primary fusing, accommodates 1-1/2" x 13/32"
midget fuse (2 rejection)
Two pole fuse block for
primary fusing, accomodates 1-1/2" x 13/32"
midget fuse (2 rejection)
Price
Order
Qty.
Order
Price
Each
$23.501$23.50
23.50123.50
Selection Guide
1. Determine inrush and sealed VA of each coil in the control circuit and VA of all other components
2. Total all sealed VA of all operating coils and other loads VA (Determines minimal VA size required for the circuit)
3. Total the inrush VA of all coils that are starting at the same time and all loads and coils that are running (using the regulation chart to give possible
units to be used)
4. Take VA size from step two, go to standard VA size in chart. Make sure inrush VA from chart is greater than total VA from step three. (If not, go to next
larger VA size and repeat)
If your supply voltage is stable and fluctuates less than 5% we recommend you use the 90% secondary voltage column. If your supply voltage is not
stable and fluctuates more than 10% we recommend you use the 95% secondary voltage column. We recommend that you never use the 85%
secondary voltage column since magnetic devices lose life expectancy if they are continuously started at 85% of rated voltage.
Field-Installable Secondary Fuse Clips
Type
SF25A 25–20025–150N/A
SF25B 250–2000 200–2000 25–2000
SF41Ab 25–20025–150N/A
SF41Bb 250–2000 200–2000 25–2000
FB1A25–20025–150N/A
FB1B250–2000 200–2000 25–2000
b SF41 can be installed on the following voltage codes: D1, D5, D24, D3, D4, D51, D2, D23,
D14, D25, D20, D95, D19, D22, D36.
Type Accessory Key
IIIIII, IV
Description
Secondary fuse block
accommodates
1-1/4" x 1/4" fuse
Secondary fuse block
accommodates
1-1/4" x 1/4" fuse
Secondary fuse clip
accommodates
1-1/2" x 13/32" midget
fuse
Secondary fuse clip
accommodates 1-1/2"
x 13/32" midget fuse
One pole fuse block
for secondary fusing,
accomodates
1-1/2" x 13/32" midget
fuse (1 non-rejection)
One pole fuse block
for secondary fusing,
accomodates
1-1/2" x 13/32" midget
fuse (1 non-rejection)
Price
Order
Qty.
Order
Price
Each
$ 6.80 10 $68.00
6.80 1068.00
5.60 1056.00
5.60 1056.00
16.40116.40
16.40116.40
Regulation Chart for Type T
Inrush VA @ 20% power factorInrush VA @ 40% power factor
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
TRANSFORMERS
12
Page 5
Industrial Control Transformers
Class 9070, 9991
www.SquareD.com
For the most up-to-date information
Transformers with Leads
Tr ansformers with leads, instead of screw terminals, are available. See the following chart
for VA sizes and voltage combinations. Consult your nearest Square D/Schneider Electric
sales office for further details. Lead length is 25".
Transformer Disconnects available in NEMA Type 1 Standard,
NEMA Type 12 Standard, and NEMA Type 1 Mini.
TRANSFORMERS
12
12-18
Class 9070 Transformer Disconnect – Improved Design
Tr ansformer disconnects mount inside or outside a control system enclosure and provide
power to auxiliary single-phase loads when the main three-phase disconnect is either
“on” or “off.” The transformer disconnect is normally wired to the line side of the control
panel's main disconnect. This convenient source of 120 V power can be used for auxiliary
or isolated loads, such as panel lighting, portable power tools, and programmable
controller equipment.
The standard enclosure is a lockable NEMA Type 1 for general purpose applications.
The disconnect switch is rated at 45 amperes, 600 volts, and has an external handle
mechanically interlocked with the enclosure cover. The handle can lock in the “off”
position. There is also a standard fusible and grounded transformer secondary.
For additional information, reference Catalog #9070CT0301.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.