AbsolutAire 243-12 User Manual

MRI-1000 - CONDENSED CAT ALOG
Industrial Service Regulators:
Models 243-12, 243-8, and 243-8HP
243
Max. Inlet Pressure = 125 PSI
Max. Outlet Pressure 243-8 = 4 1/2 PSI
Max. Outlet Pressure 243-8HP = 10 PSI
Max. Capacity 243-8 = 20,000 SCFH
Max. Capacity 243-12 = 27,000 SCFH
Max. Capacity 243-8HP = 24,000 SCFH
Overview
Equimeter’s large capacity industrial service regulators are designed and built for commercial, industrial, and gas distribution use. As a result of the union connection between the fully inter­changeable bodies and the diaphragm case, they have remarkable field versatility. They are easy to install, adjust, inspect, and service in all piping arrangements.
Applications
Equimeter’s family of large capacity industrial service regulators can be used in a variety of applications such as: factories, foundries, district regulator stations, commercial laundries, ho­tels, motels, bakeries, schools, hospital, churches, etc. They are designed for use on all types of gas fueled equipment including boilers, burners, furnaces, ovens, heaters, kilns, engines, air conditioners, etc. Although mainly used with natural gas, they perform as well when used with LPG vapor, air, dry CO2, nitrogen, and other inert gases. Please contact your Equimeter repre­sentative for information on special construction which may be available for certain corrosive gases.
Operating temperatures range from -20° F to 150° F. Equimeter 243 regulators are not recom­mended for buried service.
© Copyright 1998 Equimeter, Inc.
39
Dimensions and Specifications
snoisnemiD
rotalugeR
ledoM
-21-3422,1
-8-3422,1 PH8-342
* Dimensions are affected by mounting position, flanged or screwed connections, diaphragm case size, and whether or not the
unit is HP or standard
** Add 9 lbs. for flanges on 2” body.
.xaM
gnikroW
erusserP
)ISP(
521000,7251 521000,0221 521000,4251
.xaM
yticapaC
)HFCS(
7
5
5
thgieHhtdiWhtpeD
.niM.xaM.niM.xaM.niM.xaM
61
8
61
8
61
8
11
/
*013/6141** 72
61
11
/
*013/6141** 52
61
11
/
*013/6141** 92
61
/ / /
).ni(
**gnippihS
thgieW
).sbl(
Variations
• Variable mounting positions
• Standard Regulator (243-12-1 & 243-8-1)
• Regulator with internal relief valve (243-12-2 & 243-8-2)
• Standard regulator with low pressure cut-off (243-12-4 & 243-8-4)
• Regulator with internal relief valve and low pressure cut-off (243-12-6 & 243-8-6)
• High pressure model (243-8HP)
• Vacuum breaker model
• Monitoring and / or external control line
• Back pressure or relief valve
• Vacuum breaker model
• Pressure loaded model (243-8PL)
• Pilot operated model (243-RPC)
• Duplex overpressure tandem model (243-DOT)
• Orifice sizes: .207, 1/4, 3/8, 1/2, 3/4, 1, 1 1/4" at 10° and 3/4, 1, & 1 1/4" at 30°
40
Loading...
+ 2 hidden pages