Miniature Circuit Breaker - S200MUC - 1P - B ­25 ampere
General Information
Extended Product Type
Product ID
EAN
Catalog Description
ABB System pro M compact® product range with an MCB for DC and AC applications.
The S 200 M UC impresses with its performance range and the accordingly large
amount of approvals. Its high inbuilt short circuit breaking capacity across the
Long Description
entire model line, its flexible AC and DC application and its approval and compliance in
accordance with all major international and local standards make it truly unique.
All current System pro M compact® accessories can be combined easily with the new
model line. Whether warehousing or project engineering, planning, installing or
maintaining your equipment, the S 200 M UC is a simple and flexible solution.
The miniature circuit breaker S 200 M UC extends the established
Miniature Circuit Breaker - S200MUC - 1P - B - 25 ampere
S201M-B25UC
2CDS271061R0255
Technical
Standards
Poles
)
n
Rated Operational Voltage
acc. to IEC 60898-1 220 V DC acc. to IEC 60898-1 230 V AC acc. to IEC 60898-2 220 V DC
IEC/EN 60898-2 IEC/EN 60947-2
1 Number of Poles
1 Number of Protected
B Tripping Characteristic
25 A Rated Current (I
S201M-B25UC
acc. to IEC 60898-2 230 V AC
acc. to IEC 60947-2 253 V AC
acc. to IEC 60947-2 220 V DC
Power Loss
(Ui)
Operational Voltage
Rated Frequency (f)
Rated Short-Circuit Capacity (I
Rated Ultimate Short­Circuit Breaking Capacity (I
Circuit Breaking Capacity (I
Rated Impulse Withstand Voltage (U )
Indication
Connecting Capacity
Driver
Mounting on DIN Rail
Connection
)
cn
)
cu
)
cs
imp
IP40 in enclosure with cover; Please note polarity of device Remarks
at Rated Operating Conditions per Pole 2.88 W
acc. to IEC/EN 60664-1 484 V Rated Insulation Voltage
Maximum (Incl. Tolerance) 250 V DC
Maximum (Incl. Tolerance) 253 V AC
Maximum 253 V AC
Maximum 250 V DC
Minimum 12 V AC Minimum 12 V DC
(220 V DC) 10 kA
(230 / 400 V AC) 10 kA
(230 V AC) 10 kA (253 V DC) 10 kA
(110 V DC) 20 kA (220 V DC) 10 kA (253 V AC) 10 kA
(110 V DC) 10 kA Rated Service Short-
(6.2 kV @ sea level)
(5.0 kV @ 2000 m)
50 / 60 Hz, 1 min: 2 kV Dielectric Test Voltage
Insulation Group I, RAL 7035 Housing Material
Insulation group II, black, sealable Actuator Type
Insulation Group II, Black, Sealable Actuator Material
Red ON / Green OFF Contact Position
Screw Terminals Terminal Type
Failsafe Bi-directional Cylinder-lift Terminal Screw Terminal Type
Busbar 10 / 10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
acc. to DIN 43880 1 Installation Size
Please Note Polarity of Device Power Supply
2.88 W
DC 50 Hz 60 Hz
3 Energy Limiting Class
III Overvoltage Category
2 Pollution Degree
4 kV
I / O Actuator Marking
IP20 Degree of Protection
20000 AC cycle Electrical Endurance
20000 cycle
2.8 N·m Tightening Torque
Pozidriv 2 Recommended Screw
Any Mounting Position
69 mm Built-In Depth (t2)
2
Environmental
Operation -25 ... +55 °C Ambient Air