96 |
FLEXIBLE CABLE PROTECTION SYSTEMS FOR APPLICATIONS WITH HIGH REQUIREMENTS |
—
Sealing caps, reducers
Type NVN3, NFN3 & NR
—
Type NVN3 - Sealing cap, reinforced
|
|
|
|
|
Fits to conduit size |
|
Length |
||
|
|
|
|
|
|
|
|
|
|
|
Order no. |
|
|
NW |
Metric |
|
(mm) |
||
NVN3 |
NVN3-07 |
|
07 |
10 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-09 |
|
10 |
12 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-11 |
|
12 |
16 |
|
12.0 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-16 |
|
17 |
23 |
|
16.5 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-21 |
|
23 |
25 |
|
13.0 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-29 |
|
29 |
32 |
|
14.0 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-36 |
|
36 |
40 |
|
17.5 |
|||
|
|
|
|
|
|
|
|
|
|
|
NVN3-48 |
|
48 |
50 |
|
17.5 |
|||
|
|
|
|
|
|
|
|
|
|
In connection with PMAFIX connectors („V“ series) and PMA corrugated conduits |
|
|
|
|
|
|
|
||
For ingress protection IP68 static/IP67 dynamic |
|
|
|
|
|
|
|
||
Specially modified polyesterelastomer |
|
|
|
|
|
|
|
|
|
Free from halogens and cadmium |
|
|
|
|
|
|
|
|
|
Fits both conduit profiles – fine (T) and coarse (G) |
|
|
|
|
|
|
|
||
Temperature range: –40°C to +105°C |
|
|
|
|
|
|
|
|
|
— |
|
|
|
|
|
|
|
|
|
Type NFN3 - Sealing cap |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fits to conduit size |
|
Length |
||
|
|
|
|
|
|
|
|
||
|
Order no. |
|
NW |
Profile |
|
(mm) |
|||
NFN3 |
NFN3-07 |
|
07 |
10 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
||
|
NFN3-09 |
|
10 |
12 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
||
|
NFN3-11 |
|
12 |
16 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
||
|
NFN3-16 |
|
17 |
23 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
||
|
NFN3-21 |
|
23 |
25 |
|
9.0 |
|||
|
|
|
|
|
|
|
|
|
|
|
NFN3-29 |
|
29 |
32 |
|
|
9.0 |
||
|
|
|
|
|
|
|
|
||
|
NFN3-36 |
|
36 |
40 |
|
11.0 |
|||
|
|
|
|
|
|
|
|
||
|
NFN3-48 |
|
48 |
50 |
|
11.0 |
|||
|
|
|
|
|
|
|
|
||
In connection with PMAFIX connectors („F“ series) and PMA corrugated conduits |
|
|
|
|
|
|
|
||
For ingress protection IP67 static/IP65 dynamic |
|
|
|
|
|
|
|
||
Specially modified polyesterelastomer |
|
|
|
|
|
|
|
|
|
Free from halogens and cadmium |
|
|
|
|
|
|
|
|
|
Fits conduit profiles – fine (T) and coarse (G) |
|
|
|
|
|
|
|
||
Temperature range: –40°C to +105°C |
|
|
|
|
|
|
|
|
|
— |
|
|
|
|
|
|
|
|
|
Type NR - Reducer, PG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Thread outside |
Thread inside |
Length |
Inside Ø |
Outside Ø |
|||
|
Order no. |
PG |
PG |
(mm) |
(mm) |
(mm) |
|
||
NR |
1109N |
11 |
09 |
22.5 |
10.5 |
24.5 |
|||
|
|
|
|
|
|
|
|
||
|
1309N |
13.5 |
09 |
15.0 |
10.0 |
26.0 |
|||
|
|
|
|
|
|
|
|
||
|
1311N |
13.5 |
11 |
24.0 |
11.5 |
26.0 |
|||
|
|
|
|
|
|
|
|
||
|
1609N |
16 |
09 |
16.0 |
10.0 |
29.0 |
|||
|
|
|
|
|
|
|
|
||
|
1611N |
16 |
11 |
16.0 |
11.5 |
29.0 |
|||
|
|
|
|
|
|
|
|
||
|
1613N |
16 |
13.5 |
27.0 |
13.5 |
29.0 |
|||
|
|
|
|
|
|
|
|
||
|
2113N |
21 |
13.5 |
16.0 |
13.5 |
35.5 |
|||
|
|
|
|
|
|
|
|
||
|
2116N |
21 |
16 |
16.0 |
15.5 |
35.5 |
|||
|
|
|
|
|
|
|
|
||
|
2921N |
29 |
21 |
17.0 |
22.0 |
43.0 |
|||
|
|
|
|
|
|
|
|
||
|
3629N |
36 |
29 |
24.0 |
30.5 |
54.0 |
Reduction of threaded or clearance holes to smaller PG thread sizes
High-grade, glass fibre reinforced Polyamid 6 Temperature range: –30°C to +100°C