Non-fusible disconnect switches
OT16F3 – OT100F3
OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT100F3
Catalog number 3 pole OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT100F3
General purpose
amp rating
Catalog reference Page # 1.10 1.10 1.10 1.10 1.10 1.11 1.11 1.11
Approvals
2 pole — — — — — — — —
4 pole CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.4 CSA C22.2 No.4 CSA C22.2 No.4
Technical ratings
2
CSA,UL
Max operating voltage V 600 600 600 6
Max horsepower rating
Three phase
208V HP 3 7.5 10 15 20 10 20 25
240V HP 5 7.5 10 15 20 10 20 30
480V HP 10 15 20 30 40 20 40 50
600V HP 10 20 25 30 40 30 40 50
Single phase
120V HP 1 1.5 2 2 2 2 3 5
240V HP 2 3 5 7.5 10 5 7.5 15
Technical ratings
2
IEC
Rated insulation and operational
voltage. AC20 and DC20
Rated thermal current, Ith
AC 20/DC 20 open A 25 32 40 63 80 40 63 115
AC 20/DC 20 enclosed A 25 32 40 63 80 40 63 115
AC 21A ≤ 500V A 16 25 40 63 80 40 63 100
690V A 16 25 40 63 80 40 63 100
Rated operational power AC23
400/415V kW 7.5 9 11 22 37 15 18.5 37
690V kW 7.5 9 11 15 18.5 15 15 37
Physical characteristics
Weight 4 3
Dimension 3 pole H mm 68 68 68 91 91 100 100 100
W mm 35 35 35 53 53 70 70 70
D mm 56 56 56 72 72 75 75 75
Accessories
Terminal lug kit Integral Integral Integral Integral
Terminal shroud
Auxiliary contact
Handle CSA/UL/NEMA type
Type 1, 3R, 12
Type 1, 3R, 4, 4X, 12
Handle type
Selector • • • • • • • •
Pistol • • • • • • • •
Conversion kits
6 pole
Transfer
Bypass
Mechanical interlock
Electrical interlock — — — — — — — —
• = Available
— = Not available
1
pole Kg 0.11 0.11 0.11 0.27 0.27 0.36 0.36 0.36
A 20 30 40 60 80 30 60 100
3 pole CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.4 CSA C22.2 No.4 CSA C22.2 No.4
00 60 0 600VAC / 250VDC 600VAC / 250VDC 600VAC / 250VDC
3
V 750 750 750 750 750 750 750 750
Integral Integral Integral Integral
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
CSA approved, UL listed, IEC rated, CE marked
1 CSA 22.2 No.4 (UL98) —CSA File #LR58077, UL File # E101914 , CSA 22.2 No. 14 (UL508) —CSA File #LR58247, UL File # E63822
2 For complete technical information please see page 1.28 – 1.35.
3 1000V, IEC 408.
4 Switch only
General information : 1.1 – 1.7 Complete Non-fusible switches: 1.8 – 1.9 Components: 1.10 – 1.26 Technical information: 1.28– 1.35 Dimensions: 1.36 – 1.53
1.2