General Info MMP type MS116
General Info MMP type MS325
· Suitable for 3phase motors up to 10 HP @ 480V
· AMP range from 0.16-16A
· UL listed & CSA certi ed for Group
Motor Installation
· Wide range of accessories
· Small width (45mm)Arguments
· Save space
· High short circuit capacity
· Adjustable Overload protection
· Short circuit protection
· Phase failure detection
Technical d ata
Rated current: 0.16-16A
Rated operating voltage:
max. 600V
Tripping class:10
Max. kA IC @ 600V 30kA
Mechanical Life Time:
100,000 switches
· Suitable for 3phase motors up to 15 HP @ 480V
· AMP range from 0.16-25A
· UL listed & CSA certi ed for Group
Motor Installation
· Wide range of accessories
· Save space
· High short circuit capacity
· Adjustable Overload protection
· Short circuit protection
· Phase failure detection
· UL508 (type E) listing available
Technical d ata
Rated current:
0.16-25A
Rated operating voltage:
max. 600V
Tripping class: 10
Max. kA IC @ 600V 50kA
Mechanical Life Time:
100,000 switches
Accessories
· Auxiliary contacts (side & front)
· Under-voltage release
· Shunt trips
· Bell alarm
· Locking device
· Through the door operator
· Enclosures
· Direct contactor mounting adapter
· Suitable for Smissline busbar system up to 200A
· Busbar system
15
ABB
Accessories
· Auxiliary contacts (side & front)
· Under-voltage release
· Shunt trips
· Bell alarm
· Locking device
· Through the door operator
· Enclosures
· Direct contactor mounting adapter
· Suitable for Smissline busbar system up to 200A
· Busbar system
ABB
16
General Info MMP type MS45x
General Info MMP type MS49x
· Suitable for 3phase motors up to 40 HP @ 480V
· AMP range from 11-50A
· UL listed & CSA certi ed for Group
Motor Installation
· Wide range of accessories
· Save space
· High short circuit capacity
· Adjustable Overload protection
· Short circuit protection
· Phase failure detection
· UL508 (type E) listing available
Technical d ata
Rated current: 11-50A
Rated operating voltage:
max. 600V
Tripping class:10/20
Max. kA IC @ 600V 50kA
Mechanical Life Time:
100,000 switches
· Suitable for 3phase motors up to 75 HP @ 480V
· AMP range from 11-100A
· UL listed & CSA certi ed for Group
Motor Installation
· Wide range of accessories
· Save space
· High short circuit capacity
· Adjustable Overload protection
· Short circuit protection
· Phase failure detection
· UL508 (type E) listing available
Technical d ata
Rated current:
11-100A
Rated operating voltage:
max. 600V
Tripping class: 10/20
Max. kA IC @ 600V 100kA
Mechanical Life Time:
100,000 switches
Accessories
· Auxiliary contacts (side & front)
· Under-voltage release
· Shunt trips
· Locking device
· Through the door operator
· Enclosures
· Direct contactor mounting adapter
· Suitable for Smissline busbar system up to 200A
· Busbar system
17
ABB
Accessories
· Auxiliary contacts (side & front)
· Under-voltage release
· Shunt trips
· Locking device
· Enclosures
· Direct contactor mounting adapter
· Suitable for Smissline busbar system up to 200A
ABB
18