MO165-54
MO165-54 Manual Motor Starter Magnetic Only
General Information
Extended Product Type
Product ID
EAN
Catalog Description
The MO165 manual motor starter magnetic only is a compact and powerful range for
motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to
need for a fuse from short-circuits. The manual motor starter offers a rated service
short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with
Long Description
overload relays or motor controllers allows the protection of motors. Further features
are the built-in disconnect function, trip-free mechanism and a rotary handle with a
clear switch position indication. The manual motor starters magnetic only are suitable
for three- and single-phase applications. The handle is lockable to protect against
unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases,
shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.
MO165-54 Manual Motor Starter Magnetic Only
MO165-54
1SAM461000R1016
Ordering
1 piece
85362010 Customs Tariff Number
Popular Downloads
Information
2CDC131084D0201 Data Sheet, Technical
2CDC131082M6801 Instructions and
Rated Operational Power
Rated Operational Power
MO165-54
2
Manuals
2CDC131060M0202 Instructions and
Manuals (Part 2)
1SAM400506F0001 I²t Characteristic
1SAM400507F0001 Cut-off Current
Characteristic
1SAM400402F0001 Dimension Diagram
Dimensions
55 mm Product Net Width
142.65 mm Product Net Height
122.1 mm Product Net Depth /
Length
0.97 kg Product Net Weight
Technical
Rated Service Short­Circuit Breaking Capacity (I
)
cs
(250 V DC) 3 Poles in Series 100 kA
Rated Ultimate Short­Circuit Breaking Capacity (I
)
cu
Short-Circuit Current Setting (I
)
i
(400 V) Three Phase 22 kW
AC-3 (P
)
e
(400 V) Three Phase 22 kW
AC-3e (P
)
e
Rated Operational Voltage
Current (I
Current AC-3 (I
Current AC-3e (I
Current DC-5 (I
)
e
)
e
)
e
)
e
Rated Frequency (f)
Withstand Voltage (U
imp
)
(Ui)
Thermal Current (I
)
th
Degree of Protection
Main Circuit Terminals IP10
(230 V AC) 30 kA
(400 V AC) 30 kA (440 V AC) 30 kA (500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA (440 V AC) 45 kA (500 V AC) 20 kA
(690 V AC) 8 kA
810 A Rated Instantaneous
None Setting Range
Main Circuit 690 V AC Main Circuit 250 V DC
54 A Rated Operational
54 A Rated Operational
54 A Rated Operational
54 A Rated Operational
Main Circuit 50 Hz Main Circuit 60 Hz
Main Circuit 8 kV Rated Impulse
1000 V Rated Insulation Voltage
7 W Power Loss
3 Number of Poles
Main Circuit 54 A Conventional Free-air
Housing IP20
3 Pollution Degree
25000 cycle Electrical Durability