The outdoor station is an integral part of the ABB Welcome door communication system
and operates exclusively with components from this system. The device must only be
used with suitable ABB flush-mounted installation sockets and rain hood.
Pos: 13 /Busch-Jaeger (Neustruktur)/Mo dul-Struktur/Online-Dokumentation/Umwelt (--> Für alle Do kumente <--)/Hinweise/Hinweis - Umwelt - ABB Elektrogeräte @ 19\mod_1323162745839_15.docx @ 110867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packing materials and electric devices and their
components via the authorized collection depots and disposal companies.
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)
Page 6
ABB-Welcome
Terminal description
|
— 6 —
No.
Function
1
LED flashes slowly, indicating a call established
LED flashes fast, indicating that the system is busy
2
LED illuminates, indicating possible communication.
3
LED illuminates, indicating the door is unlocked
4
Call pushbuttons
4 Terminal description
4.1 Audio module
Fig. 1 Terminal desc ription
Page 7
ABB-Welcome
Terminal description
|
— 7 —
No.
Functions
1
Connector for camera module
2
Connector for device software update
3
Plug-in clamps (COM-NC-NO) for floating output, door opener (30VAC/DC
1A)
4
Plug-in clamps (Lock-GND) for door opener (18V 4A impulsive, 250 mA
holding)
5
Plug-in clamps (DC-GND) for additional power supply
6
Plug-in clamps (a-b) for Bus connection
7
Connector for induction loop module
8
Connector for next module
9
Connector for exit push button
10
Connector for sensor for checking the door status
11
Rotary switch for setting the address of OS (1-9)
Fig. 2 Terminal desc ription
Page 8
ABB-Welcome
Terminal description
|
— 8 —
12
Set feedback tones for push buttons: ON/OFF
13
Configure push buttons in a single column or double column mode (ON=
double column; OFF= single column)
14
Configure functions of the 1st / 2nd push button.
3->OFF, 4->OFF=call indoor station/call indoor station;
3->ON, 4->OFF=switch on lighting / call indoor station;
3->OFF, 4->ON=call guard unit / call indoor station;
3->ON, 4->ON=switch on lighting / call guard unit.
15
Adjust the loudspeaker volume.
16
Adjust the door lock release time, 1-10s (available for the
lock connected with the Lock-GND)
Page 9
ABB-Welcome
Terminal description
|
— 9 —
4.1.1 Lock connected with terminals 3&4
Page 10
ABB-Welcome
Terminal description
|
— 10 —
4.2 Camera module
Fig. 3 Terminal desc ription
Page 11
ABB-Welcome
Terminal description
|
— 11 —
No.
Functions
1
Connector for additional analog camera
2
Connector for audio module
3
Jumper for setting the video format: PAL /NTSC
4
Adjust the camera view area
Page 12
ABB-Welcome
Terminal description
|
— 12 —
4.2.1 Analog camera connected with terminal 1
All the cameras w ith the video output of 1Vp -p 75Ω ,CVB S (composite video broadcast signal) can be
connected wit h the camera module.
Generally, th e transmission dis tanc e from analog camera to the outdoor s tation ca n reach u p to 50
meters by Coax cables or about 10 meters by other typ es of cab les.
Two type s of connectio ns:
Option 1: The analog camer a is powered on all th e time
Option 2: The analog camer a is powered on only dur ing working h ours
Page 13
ABB-Welcome
Terminal description
|
— 13 —
Page 14
ABB-Welcome
Terminal description
|
— 14 —
3 pairs 2-wire
bus together
4.2.2 Detached camera connection
Camera module can be used as a detached camera, and the wiring is s hown in b elow.
Page 15
ABB-Welcome
Terminal description
|
— 15 —
Page 16
ABB-Welcome
Terminal description
|
— 16 —
No.
Functions
1
Connector for previous module
2
Connector for next module
4.3 Push button module
Fig. 4 Terminal desc ription
Page 17
ABB-Welcome
Terminal description
|
— 17 —
No.
Functions
1
Regardless of the structure of the push button module, the button numbers
are listed from the top to bottom and from left to right (in the double column
mode)
2
Lighting switch / call guard unit function is always assigned to the 1st/2nd
button.
3
User names can be printed by the labelling tool of the Welcome
configuration software.
Fig. 5 Terminal desc ription
Page 18
ABB-Welcome
Terminal description
|
— 18 —
No.
Functions
1
Program button
2
Connector for previous module
3
Connector for device software update
4
USB connector for the connection to the PC : download/upload the
configuration
5
Connector for next module
4.4 Keypad module
Fig. 6 Terminal desc ription
Page 19
ABB-Welcome
Terminal description
|
— 19 —
No.
Functions
1
Call resident
A visitor inputs an indoor station number (001) or apartment number (e.g.
0101, programmed in advance) to call a resident.
*Also, the visitor can select a resident name with the button or the
button of the accompanying display module to make a call.
Meanwhile, pressing the button can cancel the call.
*This function is only available in Pic1.
2
Calling the guard unit
A visitor can call a guard unit by pressing the button if the guard unit is
available in the system.
3
Unlocking by password
Press" + password+ “to release the lock connected with terminals
"LOCK-GND” of the audio module.
Press " +2 + + password + " to release the 2nd-lock connected
with terminals "COM-NC-NO" of the audio module.
The initial password is 123456 and residents can set their own customized
password with indoor stations.
4
System engineering configuration
Press " + + system password + " to enter the system
Pic 1
Pic 2
Fig. 7 Terminal desc ription
Page 20
ABB-Welcome
Terminal description
|
— 20 —
engineering configuration menu.
The initial system password is 345678 and it can be modified by the
administrator.
No.
Functions
1
Program button
2
Connector for previous module
3
Connector for device software update
4
Connector for Wiegand output
5
USB connector for connecting to the PC: download/upload the
configuration
6
Connector for the next module
4.5 Display and card reader module
Fig. 8 Terminal desc ription
Page 21
ABB-Welcome
Terminal description
|
— 21 —
No.
Functions
1
LCD display
2
Support ID or IC card.
Swipe the registered card to release the door lock. The card can be
programmed through the module itself, or using a PC to download the
program file. (M251021CR is accompanied with an ID card reader, while
the M251022CR is accompanied with an IC card reader.)
3
Support Wiegand output.
The default Wiegand format is 26 bits but it can also be extended to 34
bits.
Fig. 9 Terminal desc ription
*The display module must be connected after audio module.
1. Configure functions of the 1st / 2nd push button
Page 26
ABB-Welcome
Operation
|
— 26 —
No.
Functions
1
3->OFF, 4->OFF
2
Call apartment 01
3
Call apartment 02
4
Call apartment 03
No.
Functions
1
3-> ON, 4->OFF
2
Switch on light. The light is connected with a switch actuator, and the
address of the switch actuator must be same as the address of this outdoor
station.
3
Call apartment 01
4
Call apartment 02
3 4 DIP
1
2
1 2 3
4
001
002
Fig. 12 Addressing
Fig. 13 Addressing
Page 27
ABB-Welcome
Operation
|
— 27 —
No.
Functions
1
3-> OFF, 4-> ON
2
Call the guard unit. If there are multiple guard units in the same section, all
guard units will ring at the same time when a visitor presses the button
“call guard unit”.
3
Call apartment 01
4
Call apartment 02
No.
Functions
3 4 DIP
1
2
1 2 3
4
001
002
Guard unit
3 4 DIP
1
1 2 3
4
001
Guard unit
Fig. 14 Addressing
Fig. 15 Addressing
Page 28
ABB-Welcome
Operation
|
— 28 —
1
3-> ON, 4-> ON
2
Switch on lights
3
Call guard unit
4
Call apartment 01
No.
Functions
1
2-> OFF
2
Call apartment 01
3
Call apartment 02
4
Call apartment 03
5
Call apartment 04
2
ON
1
2
3
5
1
2
3
4
4
001
002
003
004
2. Configure push button in a single column or double column modes
Fig. 16 Addressing
Page 29
ABB-Welcome
Operation
|
— 29 —
No.
Functions
1
2-> ON
2
Call apartment 01
3
Call apartment 02
4
Call apartment 03
5
Call apartment 04
6
Call apartment 05
7
Call apartment 06
8
Call apartment 07
9
Call apartment 08
2
ON
1
3
5 9 7 2 4 8 6
2 4 6 8 1 3 5
7
001
001
002
003
004
005
006
007
008
Fig. 17 Addressing
Page 30
ABB-Welcome
Operation
|
— 30 —
No.
Functions
1
2-> ON,3-> ON, 4-> ON
2
Switch on lights
3
Call the guard unit
4
Call apartment 01
5
Call apartment 02
6
Call apartment 03
7
Call apartment 04
8
Call apartment 05
9
Call apartment 06
3 4 DIP
1
2
ON
3
5
9
7
2
4
8
6
2 4 6 1 3
5
Guard unit
001
002
003
004
005
006
Fig. 18 Addressing
5.1.2 Setting the language for the voice messages (if the audio
module has a speech synthesis function)
If the audio module with a speech synthesis function (M251024A-.) is assembled, the
local language can be set.
Set OS address as "0", hold the 1
Click on this button to select the language one by one.
st
button for 3s to play the voice message.
Page 31
ABB-Welcome
Operation
|
— 31 —
1
2 3 4
2 4 6 8 3 5 7
Single column
Double column
1
1
st
button
Apartment 01 A
Apartment 02 B
Apartment 03 C
Apartment 04 A
Apartment 05 B
Apartment 06 C
Outdoor station
Left building
Apartment 01 A
Apartment 02 B
Apartment 03 C
Apartment 04 D
Apartment 05 E
Apartment 06 F
Outdoor station
Gate entrance
Outdoor station
Right building
After choosing the right language, hold this button to save and exit the setting.
Fig. 19 Addressing
Pushbutton outdoor station used as gate station
If pushbutton outdoor station is set as a gate station, gateway as an important system
device must be used and it must be set as floor gateway mode.
Fig. 20
Page 32
ABB-Welcome
Operation
|
— 32 —
Detailed information please refer to “Gateway “user manual, floor gateway chapter.
The Display and card reader module can be assembled
with a push button outdoor station and the user can
swipe cards to open the door. For such combination, a
master card is needed for an electrician to manage this
outdoor station.
Register a master card/deactivate master card (we
recommend that this work is carried out by specialized
personnel):
1. Disconnect the power supply.
2. Reconnect the power
3. Hold the “program button” for 5s to enter "program
master card" interface within 30s.
4. Any card swiped by the reader during this time will
be taken to be the new MASTER card. A prompt
“Register master card successfully" will appear on
the screen.
5. If the card exists, when you swipe it again, the
information will be deleted, and a prompt “Delete
master card successfully" will appear on the
screen.
Only 1 master card can be registered.
Fig. 21
5.2 Pushbutton Outdoor Station with display module
Enter system setting using master card:
1. Swipe the MASTER card to enter the setting menu. Three LEDs will turn on.
2. 6 options:
Program Card;
Language;
Wiegand Output;
Choose Door
Date & Time;
Back
Page 34
ABB-Welcome
Operation
|
— 34 —
The keypad module can be assembled with a push
button outdoor station, and users can enter the
password to open the door.
Users can enter the system settings menu by the
following steps (during setting, press “#” to confirm,
press “*” to cancel,the default system password is
345678):
1. Set the device as an Outdoor Station or a Gate
Station.
3. Swipe the MASTER card again within 5s to change to the next option.
Or, 5s over, the current option will be chosen.
4. 30s Over, to exit the settings menu.
--- ∧
5.3 Pushbutton Outdoor Station with keypad module
--- ∧
---
Page 35
ABB-Welcome
Operation
|
— 35 —
Gate Station:
#*system password # =>
1 # => 2 #
2. Modify "system password"
#* system password # =>
2 # => Enter new password (6-8 bits) # => Enter the password again #
3. Modify "door open code"
#* system password # =>
3# => Enter new door open code (6-8 bits) # => Enter the code again #
4. Set the voice message
If the audio module with the speech synthesis function (M251024A-.) is assembled,
the local language can be set.
#* system password # =>
4# => Press or to choose the language => #
5. Enable/disable access control function
Enable access control function:
#* system password # =>
5# => 1 #
Disable access control function:
Page 36
ABB-Welcome
Operation
|
— 36 —
#* system password # =>
5# => 2 #
*Reset the system password of keypad module:
It is possible to reset the system password to factory-setting if you have forgotten it.
The restoration of default factory settings does not delete the rest of the
information programmed on the system, such as user names and other settings.
1. Disconnect the power supply.
2. Reconnect the power
3. Hold the “program button” for 5s within 30s.
4. A “di” will be sounded and the system password will be reset to the default
(345678).
Page 37
ABB-Welcome
Operation
|
— 37 —
1. By physical address
Physical address is the internal code which the outdoor
station will send through the bus connection to indoor
stations or other devices in the system. For each
apartment, physical address means the address of an
indoor station which is installed in the apartment. For
each building, physical address means the address of a
gateway which is installed for each building, and it is
also called the building number.
In standby mode, a visitor can press the physical
address corresponding to the residence that you want to
call directly, from 001 to 250.
For a complex building, a visitor needs to press the
building number (01~60) + physical address (001~250)
or make a call in the gate station.
Fig. 23
Enter Physical A
dd.:
01 001
5.4 Keypad outdoor station
5.4.1 Call a resident (3 types)
2. By logic address
Logic address is a code that a visitor can press to make a call. The code must be
assigned first and then associated with the physical address.
The apartment No. or some special codes can be used to set the logic address, which is
easy for the users to remember.
Set the logic address by taking the following steps:
Assign the logic address:
#* system password # => system setting =>
Address Book => Add =>Logic Add
Page 38
ABB-Welcome
Operation
|
— 38 —
Physical Add.:
Logic Add.:
Call Mode_______
Physical Add. ∧
Logic Add.--------
==>
No. Of digit:
Physical Add.:
User Name:
001
Turn on the “logic address” call mode
#* system password # => system setting =>
Configuration => Call mode
-4-
3. By resident name
(Remarks: this function is only available for the outdoor station with a keypad module
(M251021K-.).)
In the standby mode, press the button or the button to display resident names.
Use the buttons and to search for the desired residential station and press the
button to make a call.
Also, a visitor can enter the resident name with a keypad directly to make a call.
Resident names must be assigned first and then associated with the physical address.
#* system password # => system setting
=> Address Book => Add => Contact List
01001
5.4.2 Call the guard unit
Press the button to make a call to a guard unit.
Page 39
ABB-Welcome
Operation
|
— 39 —
30 s
==>
120 s
Accept the call
30 s
==>
120 s
Playing the message...
==>
001 s
After a “di” sound, visitor
can record the message
5.4.3 If an indoor station is in "leave home mode"
If an indoor station works in the “leave home mode”, a visitor can record a
message for the resident after entering the following interface.
5.4.4 If a guard unit is in "intercept mode"
If a guard unit works in the “intercept mode”, the call from an outdoor station to
an indoor station will be intercepted by the guard unit and after the identity is
confirmed, the guard unit will forward the call to the indoor station.
Page 40
ABB-Welcome
Operation
|
— 40 —
GU accept the call
Guard unit transfers the
call to an indoor station
30 s
==>
120 s
Call from an outdoor
station to an indoor
station
==>
120 s
==>
Page 41
ABB-Welcome
Operation
|
— 41 —
Menu__________
Configurations
Access Control
Device Type_____
Outdoor St.
∧
Gate Station
Device Type_____
Outdoor St.
Gate Station ●-
5.4.5 System settings
(During setting, press “#” to confirm, press “*” to cancel,default system password is
345678):
1. Enter the system setting menu
#*system password #
-- ∧
2. Configurations
(1) Set the device as an Outdoor Station or a Gate Station.
Outdoor Station:
#*system password # =>
Configurations # => Device Type # => Outdoor St. # (Default)
● --
Gate Station:
#*system password # =>
Configurations # => Device Type # =>Gate Station #
∧
(2) Set the call mode: make a call by a Physical Address or a Logic Code
Set the call mode by Physical Address:
#*system password # =>
Configurations # => Call mode # => Physical Address #
Page 42
ABB-Welcome
Operation
|
— 42 —
Call Mode_______
Physical Add.
Logic Add.:
Call Mode_______
Physical Add.
Logic Add.: ●-
New Password:
==>
Re-enter:
==>
Reset System
Code?
“#“ to Confirm
==>
● ∧
Set the call mode by a Logic Code,No. of digits (1-8 digits):
#*system password # =>
Configurations # => Call mode # => Logic Code #
∧
(3) System password setting
Modify the system password
#*system password # =>
Configurations # => System code # => Modify #
******
Reset the system password
#*system password # =>
Configurations # => System code # => Reset #
******
Done!
Done!
3. Access control
(1) Door open code
The password can be set as 6-8 digits. The default door open password is
"123456”, and it can be changed with an outdoor station.
Page 43
ABB-Welcome
Operation
|
— 43 —
Door Open Code__
Disable
Modify
==>
New Password:
==>
Re-enter:
==>
Reset Door Open
Code?
“#“ to Confirm
==>
Meanwhile, users can set their own passwords with indoor stations, totally, 6000
passwords can be stored.
Set the door open password ON/OFF (default: 123456)
#*system password # =>
Access Control # => Door open code # => Enable / Disable #
-- ∧
Modify the door open password
#*system password # =>
Access control # => Door open code # => Modify #
******
Reset the door open password
#* system password # =>
Access control # => Door open code # => Reset #
(2) Proximity card (3000 cards can be registered for outdoor station.)
Register cards:
Done!
******
Done!
Done!
Page 44
ABB-Welcome
Operation
|
— 44 —
Enter Card No.:
0123456
Or
==>
Enter Card No.:
0123456
Or Done!
Enter Card No.:
0123456
Or
==>
Enter Card No.:
0123456
Or Done!
Delete All
Cards?
“#“ to Confirm
==>
Physical Add.:
001
User Name:
#* system password # =>
Access control # => Proximity card # => Register card #
Delete cards:
#* system password # =>
Access control # => Proximity card # => Delete card #
4. Contact(3,000 names of the combination of 24 alphanumeric characters)
Delete all cards
#* system password # =>
Contact # => Proximity card # => Delete All #
Done!
(1) Add
Add the contact by user names
#* system password # =>
Contact # => Add # => User Names #
Page 45
ABB-Welcome
Operation
|
— 45 —
Physical Add.:
001
Logic Add.:
_______________
Alexander.G
Bodin.K
Enter Logic
Add.:
0101
Resident names must be associated with physical address.
Logic address must be associated with physical address.
(2) Modify
Modify contact by user names
#* system password # =>
Contact # => Modify # => User Names #
-- ∧
Modify the resident names and its corresponding physical address.
Modify contact by logic address
#* system password # =>
Contact # => Modify # => Logic add. #
Modify the logic address and its corresponding physical address using the
alphanumeric keypad.
(3) Delete
Delete the contact by user names
Page 46
ABB-Welcome
Operation
|
— 46 —
_______________
Alexander.G
Bodin.K
Enter Logic
Add.:
0101
Delete All Names?
“#“ to Confirm
==>
#* system password # =>
Contact # => Delete # => User Names #
-- ∧
Delete the contact by logic address
#* system password # =>
Contact # => Delete # => Logic add. #
(4) Clear all
#* system password # =>
Contact # => Clear all #
Done!
Clear all lists including resident names and logic address entries from this menu.
5. System setting
(1) Date and time
#* system password # =>
Settings # => Date & time # => Enter time and date => #
Page 47
ABB-Welcome
Operation
|
— 47 —
2013-01-01
==>
Lock(NC-NO-C)
==>
Voice Message___
On
Off
==>
No This Function!
07:00
(2) Door Open Time
#* system password # =>
Settings # => Door Open Time # => Time 1-10s (default: 3s) => #
Lock(NC-NO-C) means the lock connected with COM-NC-NO terminals.
Open
Time (1-10s)
(3) Setting the voice message on/off
If the audio module with the speech synthesis function (M251024A-.) is assembled,
the speech synthesis function can be enabled or disabled. Meanwhile, the local
language can be chosen, too.
(7) Set the related door lock when swiping the card
#* system password # =>
Settings # =>Choose Door #
●∧
Page 49
ABB-Welcome
Operation
|
— 49 —
Reset to Factory
Default?
“#“ to Confirm
==>
Audio module: ∧
V1.07_131106
Card reader:
Setting the lock which will be released when swiping the registered card:
1st (LOCK-GND): the lock connected with the LOCK-GND terminals will be released
when swiping the card.
2ND (NC-NO-COM): the lock connected with the NC-NO-COM terminals will be
released when swiping the card.
(8) Reset
#* system password # =>
Settings # => Reset # => #
Reset all settings to factory settings, but other information, e.g. user names, logic
addresses and cards information cannot be reset.
(9) Information
#* system password # =>
Settings # => Information #
View the software information of each modules of the outdoor station.
*Reset the system password of keypad module:
It is possible to reset the system password to factory-setting if you have forgotten it.
The restoration of default factory settings does not delete the rest of the
information programmed on the system, such as user names and other settings.
1. Disconnect the power supply.
2. Reconnect the power
3. Hold the “program button” for 5s within 30s.
Done!
Page 50
ABB-Welcome
Operation
|
— 50 —
4. A “di” will be sounded and the system password will be reset to the default
(345678).
In standby mode, a visitor can press the physical
address corresponding to the residence that you want to
call directly, from 001 to 250.
For a complex building, the visitor needs to press the
building number (01~60) + physical address (001~250)
to make a call from a gate station.
Fig. 24
30 s
==>
120 s
Accept the call
5.5 Keypad outdoor station without display (Camera + audio+
keypad)
5.5.1 Calling a resident, just input physical address
5.5.2 Call guard unit
Press the button to make a call to a guard unit.
5.5.3 System settings
Users can enter the system settings by the following steps (during settings, press “#” to
confirm, press “*” to cancel. The default system password is 345678.):
1. Set the device as an Outdoor Station or a Gate Station.
#* system password # =>
2 # => Enter new password (6-8 bits) # => Enter the password again #
3. Modify the "door open code"
#* system password # =>
3# => Enter new door open code (6-8 bits) # => Enter the code again #
4. Setting the voice message
If the audio module with the speech synthesis function (M251024A-.) is assembled,
the local language can be set.
#* system password # =>
4# => Press or to choose the language => #
5. Enable/disable the access control function
Enable access control function:
#* system password # =>
5# => 1 #
Disable access control function:
#* system password # =>
5# => 2 #
*Reset the system password of keypad module:
It is possible to reset the system password to factory-setting if you have forgotten it.
The restoration of default factory settings does not delete the rest of the
information programmed on the system, such as user names and other settings.
1. Disconnect the power supply.
2. Reconnect the power
3. Hold the “program button” for 5s within 30s.
4. A “di” will be sounded and the system password will be reset to the default
(345678).
We reserve the right to at all times make technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time of ordering apply to all orders. ABB
accepts no responsibility for possible errors or incompleteness in this document.
We reserve all rights to this document and the topics and illustrations contained
therein. The document and its contents, or extracts thereof, must not be reproduced,
transmitted or reused by third parties without prior written consent by ABB.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.