ABB Latch key safety limit switches Catalog Page

Latch key safety limit switches
Description
Safety limit switches with small latch (key), made of berglass reinforced UL-V0 thermoplastic material, offer double insulation and a degree of protection IP65. They are equipped with 1 N.C. + 1 N.O. or 2 N.C. contact blocks with dependent action and positive opening operation of the "N.C." contact(s).
Applications
Easy to use, the limit switches with small latch (key) offer specic qualities:
• Visible operation.
• Capability for strong current switching (conven­tional thermal current 10 A).
• Opening guaranteed of the "N.C." contact(s) when the small latch is withdrawn from the limit
switch.
• Contact blocks with dependent action and posi­tive opening operation of the "N.C." normally
closed contact(s) (symbol ).
• Electrically separated contacts (Zb shape).
• Precision on operation positions (consistency).
• Immunity to electromagnetic disturbances.
limit switches
Safety
These specic features make the limit switches ideal for monitoring and protection of industrial
machines without inertia in which downtime is
less than access time to the dangerous area. Use on sliding or pivoting protectors (covers, cases, doors, grids, etc.).
• They contribute to protection of operators working on dangerous machines, by opening the control circuit. Withdrawal of the small latch (key) by opening the mobile protector causes immediate stopping of the machine drive.
• Associated with other standard limit switches and safety switching devices, they produce automatic control circuits meeting standard EN 954-1.
• They comply with the requirements of European Directives (Low Voltage, Machines and Elec­tromagnetic Compatibility) and are conform to European and international standards.
9
2 operating head options:
Adjustable every 90° (4 x ø 3 screws with (+,-) pozidriv 1
head)
Pivoting from 0° to 360° (1 x M3 screw with Phillips
head No. 1)
Casing
30 mm wide with standardised dimensions corresponding
to EN 50047
Blocks of 2 contacts
Contact conguration: 1 N.O. + 1 N.C. or 2 N.C.
Positive opening operation
Contact dependent action
Zb shape: the 2 contacts are electrically separated
Connecting terminals
M3.5 screw with (+,-) posidriv 2 head
Screw heads with captive cable clamps
Marking conform to IEC 60947-1, IEC 60947-5-1,
EN 50005 and EN 50013 standards
Catalog number explanation
Example : L S 3 5 P 80 D 11 – S
Limit Switch .................................................................................LS
Casing width: 30 mm ..................................................................................... 3
Cable inlet:
Plastic casing .....................................................................................................................P
Operating heads:
Adjustable every 90° .......................................................................................................................... 80
Continuously pivoting from 0° to 360° ............................................................................................... 81
Contact types:
11 ........... 1 N.O. + 1 N.C. contacts
02 ........... 2 N.C. contacts
Snap action:
B ...........Zb Snap
Dependent (slow) action:
L ............Zb Slow / Simultaneous
D ...........Zb Non-overlapping late make
C ...........Zb Overlapping early make
7 small latch (key) options to be ordered separately:
Right angle key (13 or 22 mm xing)
Straight key (13 or 22 mm xing)
Straight key or right angle key with shock absorber
Adjustable right angle key
Casing fixing
2 x M4 screws in the top part
Cover
Closure by 1 x ø 3 screw with (+,-) pozidriv 1 head
Gasket made in one part to prevent tightness breaks
Electrical connection in various options:
1 x Pg 13.5 cable gland for LS30P
1 x Pg 11 cable gland for LS31P
1 x 1/2" NPT adaptor delivered not mounted for LS35P
S ............Safety device
Low Voltage Products & Systems 9.73
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202
Safety Limit Switches with Small Latch (Key)
L0490D
Double Insulation - Plastic Casing NEMA-1 - 30 and 40 mm Width Metal Casing NEMA-4X - 30 and 40 mm Width
Applications
Easy to use, the limit switches with small latch (key) offer specific qualities:
Visible operation.
Capability for strong current switching (conventional thermal current 10 A).
Opening guaranteed of the "N.C." contact(s) when the small latch is withdrawn from the limit switch.
Contact blocks with dependent action and positive opening operation of the "N.C." normally closed contact(s) (symbol ).
Electrically separated contacts.
Precision on operation positions (consistency).
Immunity to electromagnetic disturbances.
These specific features make the limit switches ideal for monitoring and protection of industrial machines without inertia in which down-time is less than access time to the dangerous area. Use on sliding or pivoting protectors (covers, cases, doors, grids, etc.).
They contribute to protection of operators working on dangerous machines, by opening the control circuit. Withdrawal of the small latch (key)
by opening the mobile protector causes immediate stopping of the machine drive.
Associated with other standard limit switches and safety switching devices, they produce automatic control circuits meeting standard EN 954-1
They comply with the requirements of European Directives (Low Voltage, Machines and Electromagnetic Compatibility) and are conform to
European an international standards.
Description
LS35P..-S (30 mm width) and LS45P..-S (40 mm width) safety limit switches with key, which are made of fibre-glass reinforced UL-V0 thermo­plastic material, offer double insulation and a degree of protection NEMA-1.
LS35M..-S (30 mm width) safety limit switches with key, which are made of zinc alloy (zamak), have a degree of protection NEMA-4X.
LS45M..-S (40 mm width) safety limit switches with key, which are made of aluminium alloy, have a degree of protection NEMA-4X.
2 operating head options:
Adjustable every 90° assembled using 4 x ø 3 screws
(L35P), 4 x ø 4 screws (L45P), 4 x M3 screws (L35M) and 4 x M4 screws (L45M)
Pivoting from 0° to 360° with 1 x M3 screw (LS35P81
or LS35M81 only)
Casing:
30 mm width with standardized dimensions according
to EN 50047
40 mm width with standardized dimensions according
to EN 50041
Block of 2 or 3 contacts
Contact configuration: 1 N.O. + 1 N.C., 2 N.C.,
1 N.O. + 2 N.C. or 3 N.C. (LS4..P/M only)
Positive opening operation
Snap action (only for blocks of 2 contacts)
● Slow action
The contacts are electricaly separated
Connecting terminals
M3.5 (+,-) posidriv 2 screw
(Screw head with captive cable clamp)
Marking conform to IEC 60947-1, IEC 60947-5-1,
EN 50005 and EN 50013 standards
Terminal for protective conductor placed near the cable inlet and marked: (LS35M & LS45M only)
M3.5 (+,–) pozidriv 2 screw(Screw head with captive cable clamp)
7 small latch (key) options (for LS35P or LS35M) and 5 small latch (key) options (for LS45P or LS45M) to be ordered separately:
Right angle key (13 or 22 mm fixing)
Straight key (13 or 22 mm fixing)
Straight key or right angle key with shock absorber
Adjustable right angle key
Mounting the casing:
2 x M4 screws in top part for 30 mm width
2 or 4 x M5 screws for 40 mm width
Cover
Closed using 1 x ø 3 screw for LS35P..-S
Closed using 3 x M3 screws for LS35M..-S
Self clipping for LS45P..-S
Closed using 2 x M4 screws for LS45M..-S
One piece sealing gasket to ensure tightness
Electrical connection:
1 (LS35P) cable inlet by 1/2" NPT plastic adaptor
1 (LS35M & LS45P/M) cable inlet for 1/2" NPT
cable gland Suitable for conduit connection only with use of adaptor sleeve optionally provided by manufacturer (on request)
.
Type Example : L S 3 5 P 8 0 D 1 1 S
L S P S
Limit Switch .................................................................................LS
Casing width: 30 mm ..................................................................................... 3
1 cable inlet by 1/2" NPT plastic adaptor (LS35P) or 1/2" NPT for cable gland
(LS35M).................................................................................................................5
Casing width: 40 mm ..................................................................................... 4
1 cable inlet for 1/2" NPT cable gland .................................................................. 5
Plastic casing..................................................................................................................... P
Metal casing ......................................................................................................................M
42
AC1300
Operating heads: (see panorama)
80 ............. Adjustable every 90°
81 ............. Continuously pivoting from 0° to 360° (LS35P & LS35M only)
S ............Safety device
Contact types:
11 ........... 1 N.O. + 1 N.C. contacts
12 ........... 1 N.O. + 2 N.C. contacts (LS45P.. or LS45M.. only)
02 ........... 2 N.C. contacts
03 ........... 3 N.C. contacts (LS45P.. or LS45M.. only)
Snap action:
B ...........Zb Snap (for 1 N.O. + 1 N.C. and 2 N.C. contacts only)
Dependent (slow) action:
L ............Slow / Simultaneous
D ...........Zb Non-overlapping late make
C ...........Zb Overlapping early make (for 1 N.O. + 1 N.C. contacts only)
Loading...