Wrist Digital Blood Pressure Monitor
Model UB-511
Instruction Manual
Original
1WMPD4000888C
Manuel d’instructions
Traduction
Traducción
Manuale di Istruzioni
Traduzione
使用手冊
翻譯
Page 2
Contents
Dear Customers..................................................................................................................................................2
Preliminary Remarks ..........................................................................................................................................2
Precautions.........................................................................................................................................................2
Contraindications ......................................................................................................................................... 3
Parts Identification..............................................................................................................................................4
Symbols..............................................................................................................................................................5
Using the Monitor................................................................................................................................................6
1. Installing / Changing the Batteries............................................................................................................ 6
2. Fastening the Cuff.................................................................................................................................... 7
3. How to Take Proper Measurements......................................................................................................... 8
4. Measurement........................................................................................................................................... 8
5. After Measurement................................................................................................................................... 8
Measurements....................................................................................................................................................9
Notes For Proper Measurement................................................................................................................. 10
Operation Mode ......................................................................................................................................... 10
What Is An Irregular Heartbeat?.......................................................................................................................11
Pressure Bar Indicator......................................................................................................................................11
WHO Classification Indicator............................................................................................................................12
About Blood Pressure.......................................................................................................................................12
What Is Blood Pressure? ........................................................................................................................... 12
What Is Hypertension And How Is It Controlled?....................................................................................... 12
Why Measure Blood Pressure At Home?................................................................................................... 13
WHO Blood Pressure Classification........................................................................................................... 13
Blood Pressure Variations .......................................................................................................................... 13
Troubleshooting................................................................................................................................................14
Maintenance.....................................................................................................................................................15
Technical Data..................................................................................................................................................15
English 1
Page 3
Dear Customers
Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.
We recommend that you read through this manual carefully before using the device for the first time.
Preliminary Remarks
This device conforms to the European Directive 93/42 EEC for Medical Products. This is made evident by the
mark of conformity accompanied by the reference number of the designated authority.
The device is designed for use on adults only, not newborns or infants. Environment for use.
The device is for use in the home healthcare environment.
This device is designed to measure blood pressure and pulse rate of people for diagnosis.
Precautions
Precision components are used in the construction of this device. Extremes in temperature, humidity, direct
sunlight, shock or dust should be avoided.
Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent. Never
use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff.
Avoid tightly folding the cuff for long periods, as such treatment may shorten the life of the components. The device and cuff are not water resistant. Prevent rain, sweat and water from soiling the device and cuff.
Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones,
X-ray or other devices with strong electrical fields.
English 2
Page 4
Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of
according to the applicable local regulations.
When reusing the device, confirm that the device is clean. Do not modify the device. It may cause accidents or damage to the device. To measure blood pressure, the wrist must be squeezed by the cuff hard enough to temporarily stop blood flow
through the artery. This may cause pain, numbness or a temporary red mark to the arm. This condition will appear especially when measurement is repeated successively. Any pain, numbness, or red marks will disappear with time.
Contraindications
The following are precautions for proper use of the device.
Do not apply the cuff to an arm with another medical electrical equipment attached. The equipment may not
function properly.
People who have a severe circulatory deficit in the arm must consult a doctor before using the device, to avoid
medical problems.
Do not self-diagnose the measurement results and start treatment by yourself. Always consult your doctor for evaluation of
the results and treatment.
Do not apply the cuff on an arm with an unhealed wound. Do not apply the cuff on an arm receiving an intravenous drip or blood transfusion. It may cause injury or
accidents.
Do not use the device where flammable gases such as anesthetic gases are present. It may cause an explosion. Do not use the device in highly concentrated oxygen environments, such as a high-pressure oxygen chamber or an oxygen
tent. It may cause a fire or explosion.
English 3
Page 5
A
Display Systolic pressure Diastolic pressure Pulse rate
Parts Identification
Battery holder cover
START button
Cuff
Part of display
Pressure bar indicator
and
WHO classification indicator
I.H.B indicator (Irregular heartbeat indicator)
Battery indicator
Carrying case
MEMORY
lkaline batteries
(LR03 or AAA)
Systolic pressure
Diastolic pressure Pulse rate
Heart mark
English 4
Page 6
Symbols
Symbols Function / Meaning Recommended Action
SN
Full Battery
low Battery
Standby and on switch Battery installation guide Direct current Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide
special protection against electrical shocks. The indicator while measurement is in progress. It blinks while detecting the pulse. Irregular Heartbeat indicator. (I.H.B.) The indicator that detects irregular heartbeats or any excessive body movement during the measurement. Previous measurements stored in MEMORY.
The battery power indicator during measurement. The battery power is low when it blinks.
Unstable blood pressure due to movement during the measurement. The systolic and diastolic values are within 10 mmHg of each other.
The pressure value did not increase during inflation. The cuff is not fastened correctly.
Measurement is in progress. Remain as still as possible.
Replace all batteries with new ones when the indicator blinks. Try measurement again. Remain very still during the measurement.
Fasten the cuff correctly, and try measurement again.
E
SYS
The pulse is not detected correctly. Systolic blood pressure in mmHg
English 5
Page 7
Symbols Function / Meaning Recommended Action
DIA
PUL./min
Diastolic blood pressure in mmHg. Pulse per minute EC directive medical device label
WEEE label Manufacturer
EU-representative Refer to instruction manual/booklet
Using the Monitor
1. Installing / Changing the Batteries
1. Slide the battery cover as shown to remove it from the device.
2. Insert two AAA / LR03 size batteries in the box, with positive (+) and negative (-) terminals matching those indicated on the cuff.
3. Slide the battery cover back on the device.
English 6
Page 8
• Insert the batteries as shown on the cuff. If not, the device will not work.
• When
time. Do not mix old and new batteries. It may cause the battery life to be shortened, or the device to malfunction.
• Battery life varies with ambient temperature and may be shorter at low temperatures.
• Remove batteries if the device is not to be used for a long period of time. The batteries may leak and cause a
malfunction.
• Use the specified batteries only. The batteries provided with the device are for testing the monitor performance
and may have a shorter life.
(LOW BATTERY mark) does not appear when the batteries are drained.
(LOW BATTERY mark) appears on the display, replace both batteries with new ones at the same
Using the Monitor
2. Fastening the Cuff
1. Wrap the cuff around your wrist about 1 cm above your hand as
shown in the figure at the right.
2. Fasten the cuff tightly using the Velcro strip.
Note: For proper measurements, fasten the cuff tightly and
measure on a bare wrist.
English 7
About 1 cm
Page 9
3. How to Take Proper Measurements
For best accuracy in blood pressure measurement:
• Sit comfortably on a chair.
Rest your arm on the table.
Do not cross your legs. Keep your feet on the floor and straighten your back.
• Relax for about 5 to 10 minutes before measurement.
• Raise your hand so that the cuff is at the same level as your heart.
• Remain still and keep quiet during measurement.
• Do not measure immediately after physical exercise or a bath.
We recommend you to rest twenty or thirty minutes before taking measurement.
• Measure your blood pressure at about the same time every day.
4. Measurement
During measurement, it is normal for the cuff to feel very tight. (Do not be alarmed.)
5. After Measurement
After measurement, press the START button to turn off the power. Remove the cuff and record your data.
Note: The device is provided with an automatic power shut-off function which turns off the power automatically
one minute after measurement.
Allow at least three minutes between measurements on the same person.
English 8
Page 10
A
t
Measurements
Note: The UB-511, once used, will provide an inflation appropriate to the user.
1. Sit comfortably with the cuff at the same level as your heart and relax.
2. Press the
START button.
The average recorded blood pressures and data number are displayed briefly.
Then the display changes as indicated in the figure on the right as measurement begins.
The cuff starts to inflate. It is normal for the cuff to feel very tight.
Note: If you wish to stop inflation at any time, press the
START button again.
3. The measurement starts automatically when pressurizing
starts, and the
(heart mark) blinks.
4. When measurement is complete, the systolic and diastolic
pressure readings and pulse rate are displayed. The cuff exhausts the remaining air and completely deflates
automatically.
5. Press the
START button again to turn off the power.
Remove the cuff.
veraged
data Data
number
Pressurizing
and
Measuremen
in progress
START
button
Systolic pressure
Diastolic pressure
WHO Classification
Pulse rate
I.H.B indicator
Note: The device is provided with an automatic power shut-off
function.
Allow at least three minutes between measurements on
the same person.
English 9
Exhausts remaining air automatically
Page 11
A
Measurements
Notes For Proper Measurement
Sit down in a comfortable position. Place the arm to be used for the measurement on a table or other support so
that the center of the cuff will be at the same height as your heart.
Relax for about five or ten minutes before taking a measurement. If you are excited or depressed by emotional
stress, the measurement will reflect this stress as a higher (or lower) than normal blood pressure reading and the pulse reading will usually be faster than normal.
An individual's blood pressure varies constantly, depending on what they are doing and what they have eaten.
What you drink can have a very strong and rapid effect on your blood pressure.
This device bases its measurements on the heartbeat. If you have a very weak or irregular heartbeat, the device
may have difficulty determining your blood pressure.
Should the device detect a condition t hat is abnormal, it will stop the measurement and display an error symbol.
See page 5 for the description of symbols.
This blood pressure monitor is intended for use by adults only. Consult with your physician before using this
device on a child. A child should not use this device unattended.
Operation Mode
1. Normal measurement with storing data (Refer to page 9) Press the Blood pressure is measured and data is stored within the device. The device can store the last thirty sets of data.
2. Recalling data Press and hold the Stored data are automatically displayed in order from the last data.
3. Clearing data Remove batteries to clear all data. Re-install them again.
START button.
START button to recall the data.
English 10
Data Stored number data
Press and hold the
START button
lternation
Page 12
g
What Is An Irregular Heartbeat?
Model UB-511 blood pressure monitor provides a blood pressure and pulse rate measurement even when an
irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement. It is important that you be relaxed, remain still and do not talk during measurements.
Note: We recommend contacting your physician if you see this indicator frequently.
Pressure Bar Indicator
The indicator monitors the progress of pressure during measurement.
Inflation in progress Measurement in progress Inflation complete
Pressurizin
English 11
Page 13
Mod
Mild
High
E
WHO Classification Indicator
Each six segments of the bar indicator correspond to the WHO blood pressure classification described on the next page.
:
WHO Classification Indicator
Severe hypertension Moderate hypertension Mild hypertension High normal Normal Optimal
The indicator displays a segment, based on the current data, corresponding to the WHO classification.
xample
erate
hypertension
hypertension
normal
About Blood Pressure
What Is Blood Pressure?
Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the
heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). One's natural blood pressure is represented by the fundamental pressure, which is measured first thing in the morning while one is still at rest and before eating.
What Is Hypertension And How Is It Controlled?
Hypertension, an abnormally high arterial blood pressure, if left unattended can cause many health problems including
stroke and heart attack. Hypertension can be controlled by altering lifestyle, avoiding stress, and with medication under a doctor’s supervision.
English 12
Page 14
p
To prevent hypertension or keep it under control:
Do not smoke Exercise regularly Reduce salt and fat intake Have regular physical checkups Maintain proper weight
Why Measure Blood Pressure At Home?
Blood pressure measured at a clinic or doctor's office may cause
apprehension and can produce an elevated reading, 25 to 30 mmHg higher than that measured at home. Home measurement reduces the effects of outside influences on blood pressure readings, supplements the doctor's readings and provides a more accurate, complete blood pressure history.
WHO Blood Pressure Classification
Standards to assess high blood pressure, without regard to age,
have been established by the World Health Organization (WHO), as shown in the chart on the right.
Blood Pressure Variations
ReferenceMaterial: Journal of Hypertension 1999, Vol 17 No.2
Grade 3 hypertension (severe) Grade 2 hypertension (moderate)
Grade 1 hypertension (mid) High-normal
Normal O
Diastolic blood pressu re
timal
Systolic blood pressure
An individual’s blood pressure varies greatly on a daily and seasonal basis. It may
vary by 30 to 50 mmHg due to various conditions during the day. In hypertensive
Typical fluctuation within a day (Measured every five minutes) Systolic
individuals variations are even more pronounced. Normally, the blood pressure rises while at work or play and falls to its lowest levels during sleep. So, do not be overly concerned by the results of one measurement.
Take measurements at the same time every day using the procedure described
in this manual to get to know your normal blood pressure. Regular readings give
Blood Pressure
Diastolic
Sleep
a more comprehensive blood pressure history. Be sure to note date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data.
English 13
Page 15
Problem Possible Reason Recommended Action
Nothing appears in the display, even when the power is turned on.
The cuff does not inflate.
The unit does not measure. Readings are too high or too low.
Other
Troubleshooting
Batteries are drained. Replace all batteries with new ones. Battery terminals are not in the correct
position. Battery voltage is too low.
(LOW BATTERY mark)
blinks. [ If the batt er i e s a re drained completely, the mark does not appear.] The cuff is not fastened properly. Fasten the cuff correctly. You moved your arm or body during the measurement.
The cuff position is not correct.
The value is different from that measured at a clinic or doctor’s office.
Reinstall the batteries with negative and positive terminals matching those indicated on the battery compartment.
Replace both batteries with new ones.
Make sure you remain very still and quiet during the measurement. Sit comfortably and still. Raise your hand so that the cuff is at the same level as your heart. If you have a very weak or irregular heat beat, the device may have difficulty in determining your blood pressure.
See “Why measure blood pressure at home?”. Remove the batteries. Place them back
properly and try measurement again.
Note: If the actions described above do not solve the problem, contact the dealer. Do not attempt to open or repair
this product yourself, as any attempt to do so will make your warranty invalid.
English 14
Page 16
Maintenance
Do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you
cannot fix the problem using the troubleshooting instructions, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare parts and units to authorized dealers.
The device was designed and manufactured for a long service life. However it is generally recommended to have
the monitor inspected every 2 years, to ensure proper functioning and accuracy. Please contact either your authorized dealer or A&D for maintenance.
Technical Data
Type
Measurement method
Measurement range Measurement accuracy
Power supply 2 x 1.5V alkaline batteries (LR03 or AAA) Number of
measurements Wrist
circumference Classification
UB-511 Clinical test Oscillometric measurement
Applied part
Pressure: 20 – 280 mmHg
Useful life
Pulse:
40 – 180 beats / minute
Pressure: ±3 mmHg
EMC
Pulse: ±5 %
Operating conditions
Approx. 400 measurements, when AAA Alkaline batteries are used, with pressure value of 170 mmHg at room temperature of 23°C
13.5 – 21.5 cm
Transport/stor age conditions
Dimensions
Internally powerd ME equipment Continuous operation mode
Weight
According to ANSI / AAMI SP-10 1992 Cuff Type BF
Device: 5 years (when used six times a day) IEC 60601-1-2: 2007
+10°C to +40°C / 15%RH to 85 %RH 800hPa to 1060hPa
-10°C to +60°C / 15%RH to 85 %RH
Approx. 63 [W] x 56 [H] x 21 [D] mm Approx. 82 g, excepting batteries
Note: Specifications are subject to change for improvement without prior notice. EMC table information is listed on our website: http://www.aandd.jp/products/manual/medical/emc_en.pdf
English 15
Page 17
1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119
A&D INSTRUMENTS LIMITED
Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485
A&D ENGINEERING, INC.
1756 Automation Parkway, San Jose, California 95131 U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408)263-0119
A&D Australasia PTY LTD
32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA Telephone: [61] (8) 8301-8100 Fax: [61] (8) 8352-7409
Loading...