AAF AstroPure 2000 Operation manuals

IOM
AstroPure
AstroPure 2000 Air Cleaner
Installation and Operation Manual
AstroPure 2000 Air Cleaner Installation and Operation Manual
Manufacturer
AAF International
European Headquarters
Odenwaldstrasse 4
D-64646 Heppenheim
Tel: +49 (0)6252 69977-0
Email: sales.DACH@aafeurope.com
12 13 19
What’s Inside
20
Purpose of this Manual
4
Safety
6
Quick Start Guide (Potentiometer Control)
7
Quick Start Guide (LCD / PLC Control)
8
General infromation
9
Storage, transport and assembly
Commissioning, Operation, Cleaning and Disposal
Emergency
Drawings and diagrams
21 21 22 23
Spare parts
Certicates and Protocols
Appendix LCD Control
Appendix Potentiometer Control
For any assistance, please
visit us at www.aafeurope.com
to nd your local AAF ofce/dealer
Purpose of this Manual
Intended Use:
DANGER:
Imminent danger that leads to severe physical injury or death
WARNING:
Possibly dangerous situation that could lead to severe physical injury or death
Before you operate the AstroPure air purier for the rst time or if you are entrusted with other work on the AstroPure air purier, you must read the operating manual.
The operating instructions help you to use the AstroPure air purier as intended, properly, effectively and safely. Therefore, read the following chapters carefully and carefully. If necessary, always look up facts that are decisive for you.
The operating instructions inform and warn you of residual risks against which a risk reduction through design and protective measures is not or not fully effective.
Target groups
Key User: Keep these instructions and other applicable documents available at the place of use of the system, also for later use. User: encourage you to read and observe these instructions and the applicable documents, especially the safety and warning notices. Observe additional system-related provisions and regulations. Qualied maintenance personnel: Read, observe and follow these instructions and other applicable documents, especially the safety and warning notices. Personnel qualication: A qualied person is understood to mean a person who has successfully completed vocational training. He/She must assess the work that has been assigned and be able to independently recognize and avoid possible dangers based on her professional training and work experience. Personnel for the maintenance and repair of ventilation devices and air lters must be trained and instructed (for example according to VDI 6022-4).
Delivery documents
The AstroPure air purier is shipped with an
installation, operation and maintenance manual,
AAF HEPA lter test report.
AstroPure air puriers are designed exclusively to free normal room air from suspended particles and to return the puried air to the room. AstroPure air puriers are intended as devices for installation exclusively in commercial and non-commercial interiors.
Foreseeable misuse:
AstroPure air puriers must not be used for any other purpose. The following foreseeable misuse is not permitted:
Extraction from an explosive atmosphere
Use as a dust extraction system
Use as a smoke extraction system
The operation of the AstroPure air purier with blocked air inlets and outlets
Independent remodeling or repair work
Operating the AstroPure air purier without instruction or training
Any other use case requires written approval from AAF International.
ATTENTION:
Potentially dangerous situation that could lead to minor physical injuries.
NOTE:
Situation that can lead to possible property damage to the AstroPure air purier.
For maintenance instructions the following documents from other supplier are supplied and must also be read and observed:
Fan: type „E“ or „Z“
LCD / PLC panel (optional)
UV-C-Stage (optional)
Orientation in these operating instructions
These operating instructions contain the following general information symbols that guide you, the reader, through the operating instructions and give you important information.
1. Safety
DANGER: ELECTRIC SHOCK
DANGER: NOISE
The unencapsulated fan can generate sound emissions> 70dB (A) (with the aintenance door open). Damage or loss of hearing can result.
EAR PROTECTIONS
Have device maintenance and repair carried out by qualied personnel only. Sufcient hearing protection must be worn during maintenance and repair work when the fan is running.
Operation may only be carried out after a instruction and training.
Maintenance and repair may only be carried out by qualied personnel.
Observe the principles for the safe operation of electrical devices.
For maintenance and repair work, the accompanying documents for the supplier components must be observed.
Hazard potential emanating from the AstroPure Air Cleaner.
Electric shock:
Electrical supply line can possibly be defective. Under no circumstances use devices with a damaged electrical connection cable.
• Check the power cords before use.
• Damaged cables must be replaced immediately.
• Electric cables must never be exposed to water, heat or sharp objects.
• Do not move the device by pulling the power cord.
• Avoid running equipment and vehicles over power lines, or provide adequate protection for them.
• The device should be in the off mode to connect or disconnect the main power supply.
• Internal cabling (fan, control panel, UV-C stage) can be defective.
• Do not continue to operate devices with an internal error and, if possible, disconnect them from the power supply.
• Carry out maintenance and repair work only when the power supply is disconnected and the AstroPure air purier is switched off.
Crushing Hazard:
Due to its own weight, there is a risk of crushing when transporting and moving the AstroPure air purier.
This can result in bruising of the extremities.
The AstroPure air purier must be moved with an appropriate method to avoid accidental injury or damage of any kind.
Preferred method is to use approved lifting gear and secured against unintentional lowering of the load:
1. protect the forklift forks before lifting
2. lift up slighty the AstroPure unit using the forklift and remove it from the wooden pallet
3. put down the AstroPure unit using the forklift
2. Quick Start Guide (Potentiometer Control)
Quick start guide
Observe the safety instructions for safe operation
Ensure a safe stand on smooth, level, stable ground/oor
Lock the castor wheels
ON / OFF switch in OFF
Set the speed controller to the “OFF” position
Plug in the power plug
ON / OFF switch ON
Check serial number for fan type on the Type Plate on the back of the uni
Serial No. : E11-2020-12345 => “E”-type Serial No. : Z11-2020-12345 => “Z”-type
Rotate speed setting to desired air volume ow according to the table below
Speed Control
Set Point
0 0 0
1 0 0
2 300 50
3 600 250
4 950 500
5 1250 750
6 1600 1050
7 1900 1350
8 2200 1650
9 2400 2000
10 2400 2300
Yellow warning lights light up:
Filters must be changed by qualied personnel
- Note the date of rst use
- Note down the operating time
- Observe and document change intervals for lters
Have the lter change and maintenance carried out by qualied personnel only
Fan TypeEFan Type
Z
Observe the protective instructions on the device. Secure the open maintenance door against unintentional closing.
DANGER: ROTATING DEVICE
Fast rotating parts of the fan The high-speed impeller of the fan can injure body parts on contact. Have device aintenance and repair carried out by qualied personnel only.
DANGER: CRUSHING HAZARD
The device can tip over if lifted (excessively). This can result in bruising of the extremities. Do not tilt the device.Set up the device outside the area of movement of people.
DANGER: CRUSHING HAZARD
There is a risk of crushing when opening the maintenance door. This can result in bruising of the extremities. Have device maintenance and repair carried out by qualied personnel only.
Step 1 Step 2 Step 3
In the event of danger or malfunction:
Pull out the mains plug and have the device serviced by qualied personnel
DANGER: CRUSHING HAZARD
Optional: The AstroPure air purier is equipped with an additional UV-C stage. UV-C radiation bears the risk to cause severe damages to the eye and skin. The UV-C stage is not accessible during normal operation.
3. Quick Start Guide (LCD / PLC Control)
4. General Information
Quick start guide
Observe the safety instructions for safe operation
Ensure a safe stand on smooth, level, stable ground
Lock the castor wheels
Plug in the power plug
Switch the ON/OFF switch at the back side of the unit to ON-position
Press the standby button to turn on the fan
To unlock the screen, enter the password “116”
Adjust volume ow rate to desired level by tapping on + (increase) or – (decrease)
Information “Service” on display:
Filters must be changed by qualied personnel
Note the date of rst use
Note down the operating time
Observe and document change intervals for lters
Have the lter change and maintenance carried out by qualied personnel only.
In the event of danger or malfunction:
Pull out the mains plug and have the device serviced by qualied personnel
The AstroPure air puriers are designed to remove particles from normal dry room air, which is returned to the room after cleaning.
The installation conditions are:
Installation indoors in a dry environment
Moving and purication of dry indoor air
Operating temperature range: 0 ° C to 40 ° C
Air humidity rH. <90%, no condensable humidity
Not approved for use in an explosive atmosphere
Filter change as described in the maintenance instructions
Carry out cleaning, maintenance and repair as specied in the maintenance instructions
and in accordance with VDI6022
Type label
The Type label of the AstroPure air purier shows the following characteristics (example below):
Image 1 : AstroPure type label
Technical characteristics
Components
Parameter
Nominal ow rate m3/h 2000
Dimensions (WxLxH) mm 770x720x1628*
Device weight kg 150*
Min. ambient temperature °C 0
Max. ambient temperature °C 40
Allowed rel. humidity level % 0-90
Connection details and power consumption
Connection details
Fan kW
UV-C stage W
Sound pressure level (SPL) at a distance of 1 m Db(A)
SFP
IP-class
Maximum recommended pressure drop:
Pre lter
RedPleat Pa
RedPleat VF Pa
Unit AstroPure - 2000
* depending on execution
1PH 230V 50 / 60Hz
0,5
25
24-55
kW/m³/s
0,513 (Fan type "E") 0,452 (Fan type "Z")
IP20
250
250
5
8
¹
10 11
13 14
12
16
9
6
7
³
4
²
Image 2 AstroPure with Potentiometer Control
HEPA lter:
AstroCel III Pa
MEGACel I Pa
Table 1 : Technical parameter of AstroPure 2000 Air Cleaner
Accompanying guidelines and documents
The installation and use conditions are:
AAF pre-lter Technical Data Sheet
AAF HEPA lter Technical Data Sheet
AAF Filter change out recommendations
AAF lter storage recommendations
Technical details of fan and UV-C stage are relevant only to service / repair personnel. For the most current versions visit us at www.aafeurope.com
450
450
5
8
¹
6
¹
9
6
7
4
³
²
Image 3 AstroPure with LCD / PLC Control
10
11
The AstroPure air purier (1) has the following main components:
Swivel castors with locking device (2)
Power plug (3) / LCD/PLC: Power plug with On/OFF switch at the back of the unit
Air inlet (4)
Air outlet (5)
Fan (6)
Pre-lter (7)
HEPA lter (8)
OptionalUV-C stage (9)
Control panel (10)
The control unit consists of the following individual parts:
ON / OFF switch (11)
Operating status light device ON (12)
Volume ow controller (13)
Status display pre-lter (14)
Status display HEPA lter (15)
LCD panel (16)
Filter and consumables
The AstroPure air puriers are equipped with the following lter stages:
Pre-lter
HEPA lter
Optional: UV-C stage
Decommissioning in the event of maintenance
The device must be switched off and disconnected from the power supply for maintenance and repair.
5. Storage, transport and assembly
Storage
The storage conditions for the AstroPure air puriers are:
Storage in a dry, protected environment, if possible in the original packaging.
Storage temperature range: -30 ° C to 40 ° C
Air humidity rH. <90%, no condensable humidity.
Unpacking
Remove the securing straps, stretch wrap, and card board packing material from the AstroPure 2000 Air Cleaner. Disposal of the packaging material must obey the local waste disposing regulations.
Castor rolls
Castor rolls are fastened on the bottom with bolts (M10, M13 wrench).
Transport
Only move heavy loads with suitable means of transport.
Installation of Air Inlet and Air Outlet ductwork (optional)
Installation of Air Inlet and Air Outlet ductwork needs to be carried out by qualied personnel only.
Installation area
The installation surface must be smooth and level and have sufcient load-bearing capacity.
DANGER: CRUSHING HAZARD
WEAR SAFETY SHOES
Avoid hard knocks and jerky loads. Risk of lter damage.
Secure the load against unintentional rolling away.
12
12 13
6. Commissioning, Operation, Cleaning and Disposal
CRUSHING HAZARD:
General
In case of any abnormal noises, sounds, and vibrations or in case of no operational sounds (no fan sound), turn the AstroPure Air Cleaner off, disconnect it from the power supply and have the equipment inspected by trained personnel.
Maintenance work must be carried out by qualied personnel only according to the
instructions by AAF as well as the personnel for the maintenance and repair of
ventilation devices and air lters must be trained and instructed (e.g. according to VDI 6022-4). Personal protective equipment (gloves, respirator, eye protection) must be worn during maintenance work inside the device and when changing the air lter.
Control panel Potentiometer Control
1. Potentiometer Control 2. LCD / PLC Control
Image 5 AstroPure Control Panel
The control unit consists of the following individual parts:
Potentiometer Control:
ON/OFF switch (11)
Operating status light device ON (12)
Volume ow controller (13)
Status display pre-lter (14)
Status display HEPA lter (15)
LCD / PLC
ON/OFF switch at the back of the unit (3)
Touch sensitive display (16)
Indicators signalling the need for
lter servicing
Initial start-up
Make sure that all four swivel castors have good contact with the installation surface and, if necessary, enable this by repositioning the device.
Make sure that the maintenance door of the device is properly closed.
Make sure that the air inlet and outlet openings are freely accessible and not obstructed
or occupied.
Fix the locking devices of the castors.
Filters:
The following lter options are installed:
Type Style Code
Pre-lter (7) RedPleat ISO Coarse 70%
RedPleat ISO ePM10 70%
RedPleat CF ISO Coarse 65%
HEPA lter (8) MEGACel I H14
ASTROCEL III H14
Operation (Potentiometer Control)
• Make sure the ON / OFF switch is in the OFF position.
• Set the volume ow controller / speed controller to a middle position.
• Plug in the power plug.
• Set the ON / OFF switch to ON.
Set the desired volume ow.
• Keep a sufcient distance from the outow openings.
• The volume ow can be regulated continuously between minimum (25% maximum volume ow) and maximum volume ow.
• Set the desired volume ow.
• Set the desired volume ow by turning the rotary knob according to set points given in the table “Quick Start Guide (Potentiometer Control)” (page 7).
WEAR SAFETY SHOES
14
The AstroPure air puriers are delivered ready for use. Perform the following work steps for initial commissioning:
Remove packaging and dispose of properly in accordance with local waste regulations.
The AstroPure air puriers are equipped with four swivel castors for easy
manoeuvrability.
14 15
Operation (LCD / PLC Control)
Plug in the power plug
Set the ON/OFF switch at the back side of the unit to ON.
Set the desired volume ow.
Press the standby button to turn on the fan
• To unlock the screen, enter the password “116”
Volume ow adjustment:
Method (1)
Press the ow rate bar to set the initial value. The exact desired speed of the fan
can be set here.
Press the plus and minus button. The respective speed increment is set in the conguration menu.
Method (2)
Press an area on the ow rate bar. With this option, the speed of the fan is set to
one of the 4 parameter values at a time (25% steps).
Information on display:
Service: lters must be changed by qualied personnel
AstroPure 2000 LCD
Conguration menu, language and system information
Press the AAF-logo eld for 5 seconds to enter the conguration menus.
Enter the password “-1101“.
The controller‘s parameters can be changed here.
Resetting of operating hours
In the conguration menu, these values can be reset by pressing the corresponding button for
5 seconds.
To access the user menu (to unlock the display), the user can press the ‘AstroPur’ logo or, alternatively, press the lock symbol for 2 seconds.
The user menu password is “116”.
AstroPure 2000 Main menu
Main User Menu
Press the AstroPure logo for 3 seconds.
The language settings can be modied and system information can be viewed (software version, hardware ID).
After 60 seconds of inactivity, the main screen will automatically ‘lock’, viz. no changes can be made to any settings, e.g., main standby switch on/off, airow set point, lamp on/off, etc.
To modify any setting, the screen needs to be unlocked again.
After 60 seconds of inactivity, the main screen will automatically ‘lock’, viz. no changes can be made to any settings, e.g., main standby switch on/off, airow set point, lamp on/off, etc.
To modify any setting, the screen needs to be unlocked again.
-> after 5 s ->
Appropriate ow rate
To achieve best air cleaning results, the air cleaners ow rate must be adjusted to the individual situation of the designated room.
Following calculation steps provide a basic guide line:
• The volume of the designated room in cubic meters (m³) is calculated by multiplying the room’s length * width * height in meters: V = L * W * H
• The desired number of room air exchanges per hour (ACH) has to be selected (units: 1 /h). This number is sometimes also referred to as air exchange rate.
When this value is not preset, the following ACH values represent the currently applied recommendations:
• Good ventilation: ACH = 4 1/h
• Excellent ventilation: ACH = 6 1/h
• Purging of rooms: ACH = 10 1/h
16
16 17
The necessary air ow rate is then determined by multiplying the room’s volume V with the desired air exchanges per hour.
• Necessary ow rate = V * ACH
Example:
• A room has the dimensions of (L * W * H) = 5 m * 8 m * 3 m
• The volume is calculated to 5 m * 8 m * 3 m = 120 m³.
• The desired air exchange rate is ACH = 4 1/h
• The air cleaner has to deliver 4 1/h * 120 m³ = 480 m³/h.
The table below serves for guidance.
Replacement Intervals
Pre lter: months 3
Red Pleat months 6
RedPleat CF months 6
HEPA Filter
AstroCel III months 12
MEGAcel I months 12
UV-C Stage hours 9.000
Parameter
Length L m 10 10 10 10
Width W m 10 10 10 10
Height H m 2 2.5 2.5 2.5
Volume V m
Air exchanges per hour ACH 1/h 4 4 6 8
Required air volume ow m3/h 800 1.000 1.500 2.000
Cleaning of the external surface
Always disconnect the AstoPure Air Cleaner from the power connection when cleaning it.
The surface of the device can be cleaned with common mild soap based household cleaning detergents only.
Disposal
Spent lters should be packed in sealed plastic bags individually and disposed off in accordance with local waste regulations.
Decommissioned electric and electronic equipment must be returned to approved collecti­on points in accordance to the local waste regulations.
Inspection and maintenance per component
The device components and lters must be checked for function and wear at regular intervals and serviced, at least after the periods specied below or earlier if necessar
Symbol Unit Example 1 Example 2 Example 3 Example 4
3
200 250 250 250
7. Emergency:
If possible, disconnect the AstroPure air purier from the power supply by pulling the plug. If it is not possible to pull out the mains plug safely, the power supply must be interrupted by disconnecting it from the building circuit (safety switch)
Fire ghting
In the event of a re, ght it with extinguishing agents approved for electrical appliances. Dangerous substances escape in the event of re. In the event of a re, do not breathe the fumes and smoke that may be produced. After ensuring that the extinguishing is complete, ensure that the rooms are adequately ventilated.
DANGER: Electric shock
18
Inspection Intervals
Pre lter: months 3
HEPA lter: months 3
UV-C Stage months 3
Maintenance door months 6
Moving parts months 6
Fan section months 6
Entire unit months Prior to each use and very 12 months
18 19
9. Spare parts:
Fan type “E”
The overall dimensions the installation dimensions of the AstroPure 2000 Air Cleaner are:
Image 5 AstroPure 2000 Dimensions
Wiring diagram
The wiring diagram for the AstroPure Air Cleaner can be found in the appendix.
The following lter options are to be used when replacing lters:
Type Style code Part number WxHxL (mm)
Pre-lter (7) RedPleat RP-4470-05920592045-CS00Z
RedPleat RP-5370-05920592045-CS02Z 555004102 (4151002424) 592 x 592 x 45
RedPleat CF RPCF-0465-05920592045-CS0Z
HEPA lter (8) MEGACel I MEGA I.eFRM.H14.610x610x292
ASTROCEL III ASTROCEL III AP A39A05C9S2R0
UV-C lamp (9)
PHILLIPS TUV 25W 1Sl/25 (BR00000777)
555001210 (4531002424)
555000951 (4139002424)
(295099013)
555004088 (1493299990)
10. Certicates and Protocols:
The unit complies to European directives and standards with European Directives and bears the CE marking. The unit is checked for tightness of the installed lters and a leak test certicate is issued. The HEPA lter has an individual test certicate which is included in the Air Cleaner’s accompanying documents or supplied with each replacement HEPA lter.
Manufacturer’s Declaration of Conformity
The AAF AstroPure Air Cleaners are manufactured in compliance with applicable international regulations and standards by:
AAF Lufttechnik GmbH Odenwaldstrasse 4 D-64646 Heppenheim Germany Telefon: +49 (0)6252 69977-0 Email: Sales.DACH@aafeurope.com
592 x 592 x 45
592 x 592 x 45
610 x 610 x 292
610 x 610 x 292
Fan type “Z”
Image 7: type label, serial number and fan type.
Fan calibration curves
A risk assessment and compliance evaluation procedure has bend conducted referenced on the following certication procedures according to the assessment as in: Machine directive 2006/42/EC, Directive on eco design EC 2009/125. Following standards and guidelines were used for the assessment of the equipment’s compliance:
Following standards and guidelines were used for the assessment of the equipment’s compliance: 2006/42/EC Machine Directive 2014/30/EC Electromagnetic Compatibility (EMC) Directive 2014/35/EC Low Voltage Directive (LVD) 2009/125/EC ERP Energy conservation 1253/2014EC ERP implementation, 2018 EN ISO 12100 General principles for design - Risk assessment and re reduction EN ISO 13857 Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs DIN EN 60335-1 Safety of electrical devices for household use and similar purposes ­ Part 1: General requirements VDI 6022-2018 Hygiene requirements for ventilation and air-conditioning systems and units - Design and construction and materials
The AAF AstroPure Air Cleaner are in full compliance with the above mentioned directives, standards and guidelines. A technical documentation of the risk and the compliance assessment is available on request from the manufacturer. Heppenheim, November 2020.
PAT Ruiter
Director Filtration technology
Heppenheim, November 2020
20
20 21
Notes
22
23
Appendix
1
2
3
4
5
6
7
POT
reproduced, copied loaned or submitted to outside parties without our written consent
A2
1 OF 1
SHEET:
:
:
Material
Finishing
MATERIAL SPECIFICATIONS
Roughness Tolerance
:
ISO2768-m
:
Ra 1.6 μm
1
2
3
4
5
6
7
8
00
LCD
reproduced, copied loaned or submitted to outside parties without our written consent
A2
1 OF 1
O.:
SHEET:
:
:
Material
Finishing
MATERIAL SPECIFICATIONS
Roughness Tolerance
:
Ra 1.6 μm
LCD Control
UL:
AP20
DRAWING. N
FM:
AAF
LCD Screen (+UV Lamp option)
PRODUCT OWNER:
AstroPure 2000 wiring diagram
DO NOT SCALE DRAWING
TITLE:
P
REVISION:
20200001D
Guillaume Fogeron
Yvan Floury
APPROVED:
DRAWN BY:
PROJECT :
AAF International
Odenwaldstraße 4, 64646 Heppenheim
Germany
This drawing is property of AAF and is loaned subject to conditions that shall not be
mm
1 : 1
19/03/2021
UNIT :
SCALE:
DATE :
PRINTED COPIES
ARE UNCONTROLLED
REF :
- ELECTRONIC DOCUMENT -
Potentiometer Control
UL:
AP2000
DRAWING. NO.:
FM:
AAF
PRODUCT OWNER:
P
REVISION:
20200001D
Guillaume Fogeron
Yvan Floury
PROJECT :
APPROVED:
DRAWN BY:
AAF International
Odenwaldstraße 4, 64646 Heppenheim
Germany
This drawing is property of AAF and is loaned subject to conditions that shall not be
mm
1 : 1
19/03/2021
UNIT :
SCALE:
DATE :
AstroPure 2000 wiring diagram potentiometer
PRINTED COPIES
ARE UNCONTROLLED
DO NOT SCALE DRAWING
TITLE:
REF :
- ELECTRONIC DOCUMENT -
OPTION :
UV LAMP
22
OPTION :
UV LAMP
24 25
NotesNotes
26
27
AAF Sales Ofces
Dinair Finland
Dinair Clean Air, Oy Koivuvaarankuja 2,
01640 Vantaa
Phone: +358 10 3222610 E-mail: cleanair@dinair.
France
AAF S.A. 9, Avenue de Paris 94300 Vincennes Phone: +33 143 984 223 Fax: +33 158 641 142 E-mail: sales.france@aafeurope.com
Germany & Austria
AAF-Lufttechnik GmbH Odenwaldstrasse 4 64646 Heppenheim Phone: +49 (0)6252 69977-0 E-mail: sales.DACH@aafeurope.com
Dinair Latvia
Dinair Filton SIA Rupnicu Street 4 Olaine, Latvia, LV-2114 Phone: +371 67069823
Dinair Denmark
AAF/Dinair APS Vallensbækvej 63.1 2625 Vallensbæk Phone: +45 70260166 E-mail: sales.denmark@aafeurope.com
Great Britain and Ireland
Air Filters Ltd (AAF International) Bassington Lane, Cramlington Northumberland NE23 8AF Phone: +44 1670 591 790 Fax: +44 1670 590 262 E-mail: airlter@aafeurope.com
Greece
AAF-Environmental Control Epe 1 Ifaistou & Kikladon 15354 Glika Nera Phone: +30 210 663 20 15 Fax: +30 210 663 51 09 E-mail: greece@aafeurope.com
Italy
AAF S.r.l. Via Friuli, 28/30 21047, Saronno (VA) Phone: +39 02.9624096 Fax: +39 02.9606409 E-mail: sales.italy@aafeurope.com
Dinair Norway
Dinair AS Prof Birkelands vei 36
1081 Oslo
Phone: +47 22 90 59 00 Fax: +47 22 90 59 09
Slovakia & Eastern Europe
AAF International s.r.o. Bratislavska 517 91105, Trencin, Slovakia Phone: +421 32/746 17 14 www.aantl.com
Spain & Portugal
AAF S.A. Vidrieros, 10 28830 San Fernando de Henares Madrid, Spain Phone: +34 916 624 866 Fax: +34 916 624 275 E-mail: info@aaf.es
Dinair Sweden
Dinair AB
Hamngatan 5 SE-592 30 Vadstena Phone: +46 (0)143-125 80 Fax: +46 (0)143-125 81
The Netherlands
AAF Verkoop Nederland Boerdijk 29A
7844 TB Veenoord
Phone: +31 (0)591 66 44 66 E-mail: aaf.verkoop@aafeurope.com
AAF International
European Headquarters
Odenwaldstrasse 4, 64646 Heppenheim
Tel: +49 (0)6252 69977-0
aantl.com
AAF International B.V. has a policy of continuous
product research and improvement and reserves
the right to change design and specications
without notice.
©2019 AAF International and
its afliated companies.
IM_102_EN_122020
Loading...