AAdynTech JAB Hurricane Light Users Manual

JAB Hurricane Light
User Manual
(IP65 Protection)
SB 220 Rev-A
1
Table of Contents
Before You Begin ...................................................................................................................................................... 3
What is Included .................................................................................................................................................. 3
Unpacking Instructions ........................................................................................................................................ 3
Symbol Definitions ............................................................................................................................................... 3
Safety Notes ......................................................................................................................................................... 3
Introduction ............................................................................................................................................................. 4
Product Description ............................................................................................................................................. 4
Features ............................................................................................................................................................... 4
Setup ........................................................................................................................................................................ 5
Mounting.............................................................................................................................................................. 5
AC Power .............................................................................................................................................................. 7
Control Selection .................................................................................................................................................. 8
Operation ................................................................................................................................................................. 8
UIM Operation ..................................................................................................................................................... 9
DMX Operation .................................................................................................................................................... 9
Technical Information .............................................................................................................................................. 9
General Maintenance and Care ......................................................................................................................... 15
Troubleshooting Guide ...................................................................................................................................... 13
Limited Warranty ............................................................................................................................................... 15
Contact Us .......................................................................................................................................................... 15
Specifications………………………………………………………………………………………………………………16
SB 220 Rev-A
2
Note: This symbol indicates important information that should be
carefully considered and followed.
Note: This symbol indicates important safety information and
third-party equipment or harm to the user.
Note: This symbol indicates important information concerning the

Before You Begin

What is Included

User’s Manual
One (1) IP65 Rated Jab Hurricane light
AC Power Input cable with plug
o USA voltage (120Vac), three-prong plug standard o One (1) 120/240v Adapter
Diffuser lens, four (4), 5
One Aadyn scrim bag, one CTO & one Minus Green Filter
One yoke pin attached
User Interface Module , UIM (Included, if purchased – Optional)

Unpacking Instructions

Immediately upon receipt of this light, carefully inspect the shipping packaging for any obvious signs of damage from mishandling or exposure to the elements. If any is noted, please provide this information to the shipper immediately so that the proper claims can be processed. Place packaging in upright position (with labeling and markings in readable orientation) and open the top end of the carton. Verify that all material shown above in the “What is included” section is present and in good condition. Remove the light and associated material from the carton and place the light on a stable surface or mounting configuration.
o
,15o, 30o and 55o

Symbol Definitions

warnings. Special attention should be paid to reading, understanding and heading these warnings. Failure to observe these warnings could result in damage to the fixture,
operation or functions of this light.
SB 220 Rev-A
3

Safety Notes

Note: This light contains no user serviceable parts. Do not open Warning! Inserting objects or fingers inside any openings or
damage to the light.
The JAB Series light fixtures are for Professional Use Only. Please Read Entire User Manual Before
Using Equipment.
This light is ETL, CSA listed for IP65 Protection and CE.
Only qualified and certified personnel should perform installation, not for household use.
JAB Hurricane Series light should always be installed/mounted in a stable and secure location or
mounting.
The JAB Hurricane Light is IP65 rated. IP65 rating indicates totally dust tight and protection against low pressure water jets in all directions (i.e. rain). UNIT IS NOT SUBMERSABLE.
Always allow adequate ventilation of the light. Never cover or in any way obstruct the louvered fins on the heatsink or the electronics housing below light.
If light is suspended either from above or below using yoke, make sure that a safety cable (not supplied) is attached to the light and properly secured. The strength of the cable/chain should be sized suitably to hold 6 times the weight the secured light.
When mounting the light, make sure that only hardware rated for the weight and size of the fixture is used and is good and proper working condition.
Never look directly into the light source while the fixture is turned on. Light source is very bright and could cause damage to eyes.
Do not probe or touch any interior features of the fixture. This includes the LED sources inside the barrel of the light. Doing so may cause damage to the fixture and/or may present a shock or burn hazard.
Always make sure that the light fixture is connected to the proper power source with proper voltage and current ratings. Also, make sure that adequate over current protection is provided for the circuit as well.
the light housing or attempt any repair or modification of the light. Failure to observe this warning could result in damage to the light, injury and voiding the limited warranty.
connectors could result in a shock hazard/injury and

Introduction

Product Description

The JAB Hurricane series light fixture is a professional grade, LED based, device which provides
exceptional light output and control. The light is capable of manual, tethered remote or DMX control and offers a full array of brightness settings as well as Strobe and Lightning functions.

Features

Manual control
UIM control
DMX control (Compatible with Slow and Fast speeds)
o Up to 500 selectable DMX addresses o Daisy-chain operation of up to 32 lights in one string o Controls Brightness, Fade, Strobe and Lightning modes
SB 220 Rev-A
4

Setup

Prior to proceeding further, make sure that light is resting on a stable surface or is
Make note of the location of the inputs and outputs along with the light controls
UIM
Out
In

Quick Start

Remove the JAB Hurricane light from its protective shipping packaging and place it in a safe and secure location for setup or use.
properly attached to a mounting location using the supplied yoke and yoke pin mounting system.
found on the rear of the light’s control box.
Connector
The AC power cable & DC power cable will be found tie wrapped & coiled up inside of the yoke attached to the power supply inside the shipping container.(if ordered with light package)
Uncoil the AC and DC cord plugging the DC female end into the DC power input located on the back of the control box (pictured above)
SB 220 Rev-A
5
Warning! Lights operate on grounded 110Vac, 50/60Hz or 240Vac, 50/60Hz
Aadyn Technology
Warning! Unit is NOT SUBMERSIBLE. Do NOT Submerge any part of the
Plug the male end of the AC power cord into an appropriate AC power source.
Turn on light by pressing the RED power switch located in the upper left hand portion of the control box,
shown above.
Using the Selector switch located on the right side of the control box select the desired mode in which you wish to operate the light. UIM, Local or DMX, see section 1.1 if the unit purchased is a Variable light, the color temperature dial will be located on the same side of the box as the Mode Selector switch and the color can be adjusted as desired using the dial for warm light, cool light or a mix of light.
Upon power up, the factory default setting will turn on the light immediately to its full brightness
unless a specific “Power On” Setting which has been previously programmed into the light. This “Power On” Setting will be covered later in these instructions.
AC Input. AC Supply Source must be sized properly and have approved protection circuitry for safe operation. Take care to observe all proper precautions when con nec ti ng po wer .
light in water or any other liquid.
If the UIM, optional remote control, is ordered with the JAB Hurricane light kit, it will be located in a
separate box within the package the Jab light was shipped in. The length of the cable is 12’. Remove the UIM from the box, uncoil the UIM cable and attach the metal connector on the cable to the UIM connector located on the control box as pic ture d.
The display on the UIM will display the following Splash Screen message upon power up.
Remote Interface
Using the Left/Right Arrow button, a desired brightness level can be selected. Other functions are
also available and can be viewed using the UIM by pressing the Up/Down arrow to the desired menu function as detailed below in section 1.0, then pressing the (√) button once a function has been selected. All of these functions are covered later in these instructions.
The (X) button on the UIM is a non-latching douse switch which, when pressed, will momentarily
extinguish the light. Releasing the switc h will allow the light to return to operation at its previous setting.
SB 220 Rev-A
6

AC Power

Warning! Standard power cord supplied with JAB Hurricane light is intended to
operation at international voltages.
Warning! Never connect JAB Hurricane series lights to anything other than a
Warning! DC power connection from external battery (not supplied) must mate
Input Power Connector on
Box
+Vdc
-Vdc
Input Power Connector on Control Box: Conxall #7382-4PG-300
Polarizing
JAB Hurricane lights operate on standard single phase AC power.
Input voltage range: 100 – 240Vac
Input frequency range: 50/60 Hz
connect with standard, single-phase 110-120 Vac, 60 Hz USA circuit. An adaptor for use with 240Vac, 50Hz European circuits is also included. Other power cords or connectors to other countries’ single phase circuits are available as options. No other special adjustments or changes are required for
single-phase circuit. Connection to three-phase power can/will cause serious damage and/or bodily injury.

DC Power

As an alternative to standard AC operation, JAB Hurricane lights can also operate on 30Vdc (max) power provided by an external battery (not supplied).
Operational Input DC voltage range: 22Vdc (min) – 30Vdc(max)
Light will not function at DC voltage ranges above or below range shown above.
properly with four pin power connector on back of light module. Contact AAdyn Technology for further details or information.
Back, Bottom-Left of Control
(Return)
Pin #1, Pin #2
SB 220 Rev-A
Mating Connector (not supplied): Conxall #63 82-4SG-321
7
Tab
(22V min – 30V max)
Pin #3, Pin #4
Note: When using DC power supplied by an external source or battery other
Manual
Douse Input Power
than standard power supply (from factory) attached to JAB Hurricane light, care should be taken to make sure that power connections are made properly. Positive DC voltage is supplied to the Input connector on Pin #3 and Pin #4 in parallel. Negative DC voltage (ground) is supplied to the Input connector on Pin #1 and Pin #2 in parallel.

Control Selection

Control of the JAB Hurricane light is by one of three means of interface: Local, UIM or DMX.

Operation

Local Operation
In the Local Mode, the operation of the light is restricted to the controls on the light itself. The light can be turned on or off via the input power switch on the back of the light. In addition to this, the light can be momentarily extinguished by pressing the Douse button on the back of the unit. (Note: the Douse button functions in all modes of operation.) The manual brightness control knob on the back of the housing can be used to adjust the brightness of the light from full-off to full-on.
Switch
Button
Brightness
SB 220 Rev-A
8
Information Display
UP/DOWN Buttons
” Button
LEFT/RIGHT Buttons
“X” Button

UIM Operation

In the UIM mode, the operation of the light is controlled by the User Interface Module (UIM). The functionality is as described below
Functional Requirements:

1.1. Mode Selector Switch

The software shall monitor a switch input to determine if the light should be in DMX mode, Local
Brightness and Color Temperature mode, or UIM mode. The switch may also be absent, if which case the UIM will need to be used to perform this function. This “LIGHT CONTROL” menu will only be present if the mode selector switch is not installed and in its place is a special jumper block that grounds the two inputs.

1.2. Local Mode (only applies to Hurricane model)

This mode shall be active when the Mode Selector switch is set to Local Mode.
The software shall monitor a potentiometer input for signal changes to indicate whether the user
wishes to make the light dimmer or brighter. The software shall also monitor a potentiometer for signal changes to indicate whether the user wishes to mix the color temperature. The requirement to monitor the color temperature potentiometer shall apply only to the Hurricane Variable Light model.
The BRIGHTNESS and COLOR TEMPERATURE controls shall be the only LED functions available
when in Local Mode.
All non-LED menu items on the UIM shall be working in Local Mode with the exception of POWER
ON SETTING at power on.
Cancel (X), (also called the Douse button), and the Douse Switch shall function in Local Mode.
This mode shall have a built-in 250 millisecond fade when changing brightness to help smooth out
the light transition.

1.3. DMX Mode

This mode shall be active when the Mode Selector switch is set to DMX. Or when
the UIM LIGHT CONTROL menu “DMX” option has been selected.
The software shall allow only the DMX input to adjust the LED functions while in
DMX Mode.
SB 220 Rev-A
9
All non-LED menu items on the UIM shall be working in DMX Mode with the exception of POWER
ON SETTING at power on.
The back panel Douse Switch and the UIM Douse Button shall function in DMX Mode.
This mode shall not have any built-in fade when changing brightness.

1.4. UIM Mode

This mode shall be active when the Mode Selector switch is set to UIM. Or when the UIM LIGHT
CONTROL menu “UIM” option has been selected.
The software shall allow only the UIM input to adjust the LED functions while in UIM Mode.
The Douse Switch and the Douse Button shall function in UIM Mode.
This mode shall have a built-in 250 millisecond fade when changing brightness to help smooth out
the light transition.

1.5. Proprietary User Interface Module Requirements

All functions in this section shall be available for use when the Mode Selector switch is set to UIM
mode. Or when the UIM LIGHT CONTROL menu “UIM” option has been selected.
The software shall display a menu of parameters on the UIM controller. The parameters listed below shall be displayed in the order shown from top to bottom when the down key is pressed and shall default to UIM BRIGHTNESS. When the up key is pressed the order will proceed from LIGHT CONTROL to the bottom of the list, then upwards.
UIM BRIGHTNESS
UIM COLOR (Jab Variable model)
UIM FADE
UIM EFFECT SELECT
UIM EFFECT FREQUENCY
DMX BASE ADDRESS
DMX CHANNEL MODE
MODEL NAME / SOFTWARE VERSION / RECALIBRATION PT
POWER ON SETTING
SAVE CUSTOM
RECALL SETTI NG
LIGHT CONTROL (only if mode switch is absent)
Under each parameter, the software shall present settings pertaining to the parameter for the user to
select. The settings shall be:
BRIGHTNESS parameter:
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
Each setting value shall represent a brightness level where 0 percent is off and 100
percent is the maximum brightness of the light.
The change from one brightness value setting to another value shall be as smooth as
possible. The built in smoothing delay shall be 250ms. If the BRIGHTNESS slider on a DMX board is taken from a positive value all the way to 0, the software shall not implement any delay unless FADE is non-zero and turn the light off immediately.
At power on, the factory default value of UIM BRIGHTNESS shall be set at 100%. If a
power on profile is selected that brightness setting will be used. If there is no power on profile, the brightness will be the ‘last used’ level.
COLOR TEMP parameter (applies only to Jab Variable Light model):
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
Each setting value shall represent a light color temperature level
where 0 percent is completely cool and 100 percent is the maximum warm setting of the light.
SB 220 Rev-A
10
At power on, the factory default value of UIM COLOR TEMP shall default to 50 percent.
If a power on profile is selected that associated br ig htn es s level wi ll be used, else the ‘last used’ brightness level will be used.
FADE parameter:
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
Each setting value shall represent a delay in the increase or decrease of the
BRIGHTNESS parameter.
0 shall indicate that the BRIGHTNESS parameter change is to occur immediately and
100 percent shall introduce a three second delay in changing the current parameter value to the requested value.
At power on, the factory default value of UIM FADE shall default to 0 percent. If there is
a power on profile, its associated FADE level shall be used, else the ‘last used’ value will be used.
EFFECT SELECT parameter:
The software shall present individually thirteen choices for the EFFECT SELECT
parameter:
NONE (OFF) – Turn off any current effect
STROBE,
LIGHTNING1 SGL,
LIGHTNING1 RPT,
LIGHTNING2 SGL,
LIGHTNING2 RPT,
LIGHTNING3 SGL,
LIGHTNING3 RPT,
LIGHTNING4 SGL,
LIGHTNING4 RPT,
LIGHTNING5 SGL,
LIGHTNING5 RPT,
LIGHTNING CYCL
The choice shall change by one each time a right or left arrow button is pressed.
STROBE shall make the LEDs emit pulses of light at a 30 percent on/70 percent off duty
cycle and that are of a user designated frequency and brightness. These parameters are EFFECT FREQUENCY and BRIGHTNESS.
LIGHTNINGx SGL shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. SGL indicates that this sequence shall be shown only once per user request. The length and brightness components of lightning shall be defined in the software. There shall be five different sequences of lightning defined and designated by a number where the x is located.
LIGHTNINGx RPT shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. RPT indicates that this sequence shall be shown repeatedly, with each sequence separated by a two second off interval. The length and brightness components of lightning shall be defined in the software. The same five single sequences defined above shall be used for the repeat lightning.
LIGHTNING CYCL shall show each sequence in order with each sequence separated
by a two second off interval. At the end of the fifth sequence, the process shall be repeated.
If a LIGHTNING effect has been started, it shall be completed even if the user disables
effects during the sequence.
At power on, the factory default UIM EFFECT SELECT shall default to
NONE(OFF). If there is a power on profile the effect associated with that profile will be used, else the ‘last used’ value will be used.
EFFECT FREQUENCY parameter:
SB 220 Rev-A
11
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
The power on default value of the UIM EFFECT FREQUENCY parameter shall be 75
percent. If a POWER ON SETTING has been selected, the EFFECT FREQUENCY shall be the value specified in that setting. If the POWER ON SETTING is turned OFF, the software shall use the ‘last used’ value’.
Each setting value shall represent how quickly the lightning and strobe effects operate.
Higher numbers represent a slower effect.
RECALL SETTING parameter:
The software shall present individually fifteen choices to the user: PRESET1, PRESET2,
PRESET3, and CUSTOM1 through CUSTOM12 changing the choice each time a right or left arrow button is pressed. The CUSTOM settings are described below.
The PRESET settings shall be hard coded into the software and not changeable by the
user.
When the user presses the select (green check) button, the software shall set the
BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY, DMX Channel, DMX Channel Mode, and COLOR TEMP (if the light is a Jab Variable model) parameters with the saved settings from a CUSTOM or a PRESET, given the profile the user has chosen.
At power on, the RECALL SETTING that is displayed (but not selected) shall default to
PRESET1 if there is no power on profile.
For all 3 Presets the FADE and EFFECT FREQUENCY shall be zero, and the effect
shall be NONE. Also for all presets the DMX base address shall be 1 and the DMX Channel Mode shall be 6.
There shall be three factory presets for the Jab Variable light. For each, the
BRIGHTNESS shall be 100%. Preset one shall set COLOR TEMP at 100%, Preset two shall set the COLOR TEMP at 45% and Preset three shall set the COLOR TEMP at 10%.
For the Jab Tungsten and Jab Daylight models the Color temp will always be 0%. Preset
1 will have 100% brightness, Preset 2 will have 45% brightnes s , and Pres et 3 will have 25% brightness.
For all presets the DMX channel will be 1 and the Channel Mode will be 6.
SAVE CUSTOM parameter:
The software shall present individually twelve choices to the user: CUSTOM1 through
CUSTOM12 changing the choice each time the right or left arrow button is pressed.
When the custom setting is selected (green check button) by the user, the software shall
save the BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY, DMX Channel, DMX Channel Mode, and COLOR TEMP (if the light is a Jab Variable model) to non-volatile memory.
POWER ON SETTING parameter:
The software shall individually present sixteen choices to the user: PRESET1,
PRESET2, PRESET3, CUSTOM1 through CUSTOM12, and OFF changing the choice each time the right or left arrow button is pressed.
When the setting is selected by the user, the software shall save this choice to non-
volatile memory.
When the light is powered on, the software shall check to see if there is a startup profile
selected and set the BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY and COLOR TEMP (if the light is a Jab Variable model) parameters with the saved settings from the profile.
If no power on default is selected when the light is powered up in UIM control mode the
firmware shall restore BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY and COLOR TEMP (if the light is a Jab Variable model) settings that were saved from the last time the light was used These settings shall be automatically saved every two seconds if any have changed since the last check.
SB 220 Rev-A
12
At power on, POWER ON SETTING shall default to OFF if there is no power on profile.
MODEL NAME parameter:
Each model shall have its name displayed on the UIM MODEL NAME screen.
The name shall be one of the following: JAB DAYLIGHT, JAB TUNGSTEN or JAB
VARIABLE, depending on which model is being built.
RECALIBRATION PT parameter:
The software shall start at 25000 hours and count down to zero and then count
negatively if necessary to let the user know it is time to have the LED’s replaced. The time shall count down based on hours of continuous use at a particular brightness setting.
SOFTWARE VERSION parameter:
The software shall maintain and display the software version.
It shall be in the form: MajorVersion.MinorVersion.Build
DMX BASE ADDRESS parameter:
This parameter shall range between 1 and 512. It shall represent the DMX address on
the network that is used to address the light.
DMX CHANNEL MODE
There shall be three modes of operation when the light is under DMX control. These
modes are called: 2 CHANNEL, 3 CHANNEL, and 6 CHANNEL mode. In all modes the first slider controls brightness. In 2 channel mode the second slider controls color temperature for the Jab Variable model, and has no effect on the other two models. The third slider controls fade in 3 and 6 channel modes. In 6 channel mode slider 4 controls effect selection, 5 controls effect frequency, and slider 6 controls effect activation.
The factory default for the DMX CHANNEL MODE shall be 6 CHANNELS mode.
LIGHT CONTROL (Only applies to Jab models)
There shall be two control modes of operation when the Mode Select switch is absent.
These modes are called: UIM and DMX. In UIM mode the UIM controls all light functions. In DMX mode the DMX interface controls all light functions.
The factory default for the LIGHT CONTROL shall be UIM.
The software shall implement medium, medium fast and fast scroll where noted. If the Right or Left
Arrow button is held down for one half second, the values shall be medium scrolled on the display. If the Arrow button is held down for two seconds the values shall be medium fast scrolled on the display. If the Arrow button is held down for six seconds the values shall be fast scrolled by five on the display.
The software shall make sure that the LED’s are powered by the slave PWM processor based on default settings and/or any saved profile described under POWER ON SETTING before detecting the presence of a UIM (User Interface Module).
If a UIM cannot be detected at light startup, the software shall transmit the AADYN TECHNOLOGY splash screen and check again next time through the main loop. If a UIM is attached after startup, the software shall display the BRIGHTNESS screen after a five (5) second delay with the splash screen being shown.
If the UIM is removed after startup, the software shall maintain the current settings. If the UIM is reattached later, the splash screen shall show again and any value in the buffer shall be processed. The software shall retain the menu state after the UIM is unplugged and, if the UIM is reattached, the splash screen shall show again until any button is pressed. If a benign button is pressed, then the previous menu shall be displayed; otherwise, the button shall be acted upon and the display shall be updated appropriatel y.
The backlight of the UIM shall be tuned off if the user does not press any button for a period of two minutes. The next subsequent button press shall only turn the backlight on with no additional action being taken. This includes the UIM douse button.
SB 220 Rev-A
13

1.6. Douse Switch/Douse Button

The software shall monitor an I/O pin to determine if a momentary switch connected to the light has
been pressed and shall turn off the light for the duration of the switch press.
Upon release, the software shall allow the light to return to its currently set brightness level if the
Cancel button on the UIM is not pressed.
The software shall separately detect and process a press and release of the red Cancel (X) button
from the UIM. On Cancel button press, the software shall turn off the LED’s immediately. On Cancel button release, the software shall turn on the LED’s immediately if the Douse switch is not being pressed.

1.7. DMX Controller Interface Requirements

The software shall accept input from the DMX512 controller that represents user requested values
for BRIGHTNESS, COLOR TEMP (if light model is a Jab Variable), FADE, EFFECT, EFFECT FREQUENCY and EFFECT ACTIVATION.
The DMX input to the light is mapped as follows:
Channel 1: Brightness: 0 – 255
Channel 2: Color Temperature: 0 – 255
Channel 3: Fade: 0 – 255
Channel 4: Effects: 0: No Effect Selected 1 – 40: Lightning 1 Selected 41 – 80: Lightning 2 Selected 81 – 120: Lightning 3 Selected 121 – 160: Lightning 4 Selected 161 – 200: Lightning 5 Selected 201 – 255: Strobe Selected
Channel 5: Effect Frequency: 0 – 255
Channel 6: Effect Activation 0: Effect Deactivated 1 – 255: Effect Activated
SB 220 Rev-A
14

Technical Information

General Maintenance and Care

This light is intended for indoor or outdoor use. When not in use, the light should be stored in a
generally dry and dust free area. General maintenance and care consists of making sure that the light always has good ventilation and that nothing is obstructing free air flow through and around the light. Do not use chemicals to clean light. Any cleaning of the light, especially the LED optics should be with a damp, not wet, soft cloth that is non-abrasive.
Limited Warranty
AADYN TECHNOLOGY, LLC

LIMITED WARRANTY

AAdyn Technology, LLC (“AAdynTech”) products are covered by a limited warranty against
manufacturing defects for two (2) years from the date of purchase by the original purchaser. AAdynTech’s liability is limited, a t AAdynTech’s option , to repair or r eplacement of the product with the s ame or an equiv alent product and does not include i nstallatio n costs, r emoval cos ts, or tra nsportatio n costs. AA dynTech res erves the right to determine whether the AAd ynTech product is defective. D amage due to norm al wear and tear, incorrec t installation, misuse, abuse, accident, or any cause other than a manufacturing defect is not covered by the warranty. AAdynTech d isclaim s an y liability for damage to pr oducts, a dapters, ot her prop erty, or per sona l injur y resulting in whole or in part, from im proper installation or use of its prod ucts. Components not manufacture d by AAdynTech are subject to t he warranty or guarante e set forth by the manuf acturer thereof, and then on ly to the extent AAdynTech is able to enforce the warranty or guarantee.
In order to mak e a war ranty c laim , you m us t notif y AAd ynTech in wr iting within s ixt y (60) da ys af ter your
discovery of the defec t, obtain from AAdynTech an RMA, t hen provide proof of purchase, such as the invoice, and promptly return the product to AAdynTech or its authorized service provider, freight prepaid.
THE FOREGOIN G WARRANTY PROVISION S ARE EXCLUSIVE AND ARE G IVEN AND ACCEPTED
IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTY AGAINST INFRINGEMENT AND ANY IMPLIED WARRANT IES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IN NO EVENT SHALL AADYNTECH BE LIABLE FOR INCIDENTAL, COMPENSATORY,
CONSEQUENTIAL, DIRECT, SPECIAL OR OTHER DAMAGES. AADYNTECH’S AGGREGATE LIABILITY WITH RESPECT TO A DEFECTIVE PRODUCT SHALL IN ANY EVENT BE LIMITED TO THE REPAIR OR REPLACEMENT O F T H AT DEFE CT IVE PRODUCT O R, AT AADYNTECH ’S OPTION, TH E REIMBURSEME NT OF THE PURCHASE PRICE THEREFOR.
This warranty is effec tive for purchases of AAdynTech’s pr oduct on or after the eff ective date set forth
below. AAdynTech reserve s the right to modify this warranty from tim e to tim e. Any modif ic ation of this war ranty shall be effective for all orders placed with AAdynTech on or after the effective date of such revised warranty.
Effective Date: November 11, 2014

All prices and specifications are subject to change without notice.

Contact Us

Aadyn Technology, LLC 80 Route 4 East, Suite 120 Paramus NJ (201) 368-2800
SB 220 Rev-A
15
Jab Hurricane
No Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 83,520 25,410 11,560
Ft. Candles 7,759 2,360 1,073
5° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 59,340 17,930 8,050
Ft. Candles 5,512 1,665 747
15° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 43,330 12,710 5,740
Ft. Candles 4,025 1,180 533
30° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 15,890 4,460 2,020
Ft. Candles 1,476 414 188
55° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 5,995 1,415 690
Ft. Candles 557 131 64
Dimension
s
Length
339.0
mm
13.3 in
Width
326.5
mm
12.9 in
Height
554.9
mm
21.8 in
Weight
8.9 kg
19.5 lb
s
SB 220 Rev-A
16
Loading...