Before You Begin ...................................................................................................................................................... 3
What is Included .................................................................................................................................................. 3
Symbol Definitions ............................................................................................................................................... 3
Features ............................................................................................................................................................... 4
AC Power .............................................................................................................................................................. 7
Control Selection .................................................................................................................................................. 8
Technical Information .............................................................................................................................................. 9
General Maintenance and Care ......................................................................................................................... 15
Contact Us .......................................................................................................................................................... 15
Note: This symbol indicates important information that should be
carefully considered and followed.
Note: This symbol indicates important safety information and
third-party equipment or harm to the user.
Note: This symbol indicates important information concerning the
Before You Begin
What is Included
• User’s Manual
• One (1) IP65 Rated Jab Hurricane light
• AC Power Input cable with plug
o USA voltage (120Vac), three-prong plug standard
o One (1) 120/240v Adapter
• Diffuser lens, four (4), 5
• One Aadyn scrim bag, one CTO & one Minus Green Filter
• One yoke pin attached
• User Interface Module , UIM (Included, if purchased – Optional)
Unpacking Instructions
Immediately upon receipt of this light, carefully inspect the shipping packaging for any obvious signs of
damage from mishandling or exposure to the elements. If any is noted, please provide this information
to the shipper immediately so that the proper claims can be processed. Place packaging in upright
position (with labeling and markings in readable orientation) and open the top end of the carton. Verify
that all material shown above in the “What is included” section is present and in good condition.
Remove the light and associated material from the carton and place the light on a stable surface or
mounting configuration.
o
,15o, 30o and 55o
Symbol Definitions
warnings. Special attention should be paid to reading,
understanding and heading these warnings. Failure to
observe these warnings could result in damage to the fixture,
operation or functions of this light.
SB 220 Rev-A
3
Safety Notes
Note: This light contains no user serviceable parts. Do not open
Warning! Inserting objects or fingers inside any openings or
damage to the light.
The JAB Series light fixtures are for Professional Use Only. Please Read Entire User Manual Before
Using Equipment.
• This light is ETL, CSA listed for IP65 Protection and CE.
• Only qualified and certified personnel should perform installation, not for household use.
• JAB Hurricane Series light should always be installed/mounted in a stable and secure location or
mounting.
•The JAB Hurricane Light is IP65 rated. IP65 rating indicates totally dust tight and protection against
low pressure water jets in all directions (i.e. rain). UNIT IS NOT SUBMERSABLE.
•Always allow adequate ventilation of the light. Never cover or in any way obstruct the louvered fins
on the heatsink or the electronics housing below light.
•If light is suspended either from above or below using yoke, make sure that a safety cable (not
supplied) is attached to the light and properly secured. The strength of the cable/chain should be
sized suitably to hold 6 times the weight the secured light.
•When mounting the light, make sure that only hardware rated for the weight and size of the fixture is
used and is good and proper working condition.
•Never look directly into the light source while the fixture is turned on. Light source is very bright and
could cause damage to eyes.
•Do not probe or touch any interior features of the fixture. This includes the LED sources inside the
barrel of the light. Doing so may cause damage to the fixture and/or may present a shock or burn
hazard.
•Always make sure that the light fixture is connected to the proper power source with proper voltage
and current ratings. Also, make sure that adequate over current protection is provided for the circuit
as well.
the light housing or attempt any repair or modification of the
light. Failure to observe this warning could result in damage
to the light, injury and voiding the limited warranty.
connectors could result in a shock hazard/injury and
Introduction
Product Description
The JAB Hurricane series light fixture is a professional grade, LED based, device which provides
exceptional light output and control. The light is capable of manual, tethered remote or DMX control and
offers a full array of brightness settings as well as Strobe and Lightning functions.
Features
• Manual control
• UIM control
• DMX control (Compatible with Slow and Fast speeds)
o Up to 500 selectable DMX addresses
o Daisy-chain operation of up to 32 lights in one string
o Controls Brightness, Fade, Strobe and Lightning modes
SB 220 Rev-A
4
Setup
Prior to proceeding further, make sure that light is resting on a stable surface or is
Make note of the location of the inputs and outputs along with the light controls
UIM
Out
In
Quick Start
Remove the JAB Hurricane light from its protective shipping packaging and place it in a safe and secure location
for setup or use.
properly attached to a mounting location using the supplied yoke and yoke pin
mounting system.
found on the rear of the light’s control box.
Connector
The AC power cable & DC power cable will be found tie wrapped & coiled up inside of the yoke attached to the
power supply inside the shipping container.(if ordered with light package)
•Uncoil the AC and DC cord plugging the DC female end into the DC power input
located on the back of the control box (pictured above)
SB 220 Rev-A
5
Warning! Lights operate on grounded 110Vac, 50/60Hz or 240Vac, 50/60Hz
Aadyn Technology
Warning! Unit is NOT SUBMERSIBLE. Do NOT Submerge any part of the
• Plug the male end of the AC power cord into an appropriate AC power source.
• Turn on light by pressing the RED power switch located in the upper left hand portion of the control box,
shown above.
•Using the Selector switch located on the right side of the control box select the desired mode in which
you wish to operate the light. UIM, Local or DMX, see section 1.1 if the unit purchased is a Variable light,
the color temperature dial will be located on the same side of the box as the Mode Selector switch and
the color can be adjusted as desired using the dial for warm light, cool light or a mix of light.
•Upon power up, the factory default setting will turn on the light immediately to its full brightness
unless a specific “Power On” Setting which has been previously programmed into the light. This
“Power On” Setting will be covered later in these instructions.
AC Input. AC Supply Source must be sized properly and have
approved protection circuitry for safe operation. Take care to
observe all proper precautions when con nec ti ng po wer .
light in water or any other liquid.
• If the UIM, optional remote control, is ordered with the JAB Hurricane light kit, it will be located in a
separate box within the package the Jab light was shipped in. The length of the cable is 12’. Remove
the UIM from the box, uncoil the UIM cable and attach the metal connector on the cable to the UIM
connector located on the control box as pic ture d.
•The display on the UIM will display the following Splash Screen message upon power up.
Remote Interface
•Using the Left/Right Arrow button, a desired brightness level can be selected. Other functions are
also available and can be viewed using the UIM by pressing the Up/Down arrow to the desired menu
function as detailed below in section 1.0, then pressing the (√) button once a function has been
selected. All of these functions are covered later in these instructions.
•The (X) button on the UIM is a non-latching douse switch which, when pressed, will momentarily
extinguish the light. Releasing the switc h will allow the light to return to operation at its previous
setting.
SB 220 Rev-A
6
AC Power
Warning! Standard power cord supplied with JAB Hurricane light is intended to
operation at international voltages.
Warning! Never connect JAB Hurricane series lights to anything other than a
Warning! DC power connection from external battery (not supplied) must mate
Input Power Connector on
Box
+Vdc
-Vdc
Input Power Connector on Control Box: Conxall #7382-4PG-300
Polarizing
JAB Hurricane lights operate on standard single phase AC power.
• Input voltage range: 100 – 240Vac
• Input frequency range: 50/60 Hz
connect with standard, single-phase 110-120 Vac, 60 Hz USA circuit. An
adaptor for use with 240Vac, 50Hz European circuits is also included. Other
power cords or connectors to other countries’ single phase circuits are
available as options. No other special adjustments or changes are required for
single-phase circuit. Connection to three-phase power can/will cause serious
damage and/or bodily injury.
DC Power
As an alternative to standard AC operation, JAB Hurricane lights can also operate on 30Vdc (max)
power provided by an external battery (not supplied).
• Operational Input DC voltage range: 22Vdc (min) – 30Vdc(max)
• Light will not function at DC voltage ranges above or below range shown above.
properly with four pin power connector on back of light module. Contact AAdyn
Technology for further details or information.
Note: When using DC power supplied by an external source or battery other
Manual
Douse
Input Power
than standard power supply (from factory) attached to JAB Hurricane light, care
should be taken to make sure that power connections are made properly.
Positive DC voltage is supplied to the Input connector on Pin #3 and Pin #4 in
parallel. Negative DC voltage (ground) is supplied to the Input connector on Pin
#1 and Pin #2 in parallel.
Control Selection
Control of the JAB Hurricane light is by one of three means of interface: Local, UIM or DMX.
Operation
Local Operation
In the Local Mode, the operation of the light is restricted to the controls on the light itself. The light can
be turned on or off via the input power switch on the back of the light. In addition to this, the light can be
momentarily extinguished by pressing the Douse button on the back of the unit. (Note: the Douse
button functions in all modes of operation.) The manual brightness control knob on the back of the
housing can be used to adjust the brightness of the light from full-off to full-on.
Switch
Button
Brightness
SB 220 Rev-A
8
Information Display
UP/DOWN Buttons
“√” Button
LEFT/RIGHT Buttons
“X” Button
UIM Operation
In the UIM mode, the operation of the light is controlled by the User Interface Module (UIM). The
functionality is as described below
Functional Requirements:
1.1. Mode Selector Switch
•The software shall monitor a switch input to determine if the light should be in DMX mode, Local
Brightness and Color Temperature mode, or UIM mode. The switch may also be absent, if which
case the UIM will need to be used to perform this function. This “LIGHT CONTROL” menu will only
be present if the mode selector switch is not installed and in its place is a special jumper block that
grounds the two inputs.
1.2. Local Mode (only applies to Hurricane model)
• This mode shall be active when the Mode Selector switch is set to Local Mode.
• The software shall monitor a potentiometer input for signal changes to indicate whether the user
wishes to make the light dimmer or brighter. The software shall also monitor a potentiometer for
signal changes to indicate whether the user wishes to mix the color temperature. The requirement to
monitor the color temperature potentiometer shall apply only to the Hurricane Variable Light model.
•The BRIGHTNESS and COLOR TEMPERATURE controls shall be the only LED functions available
when in Local Mode.
•All non-LED menu items on the UIM shall be working in Local Mode with the exception of POWER
ON SETTING at power on.
• Cancel (X), (also called the Douse button), and the Douse Switch shall function in Local Mode.
• This mode shall have a built-in 250 millisecond fade when changing brightness to help smooth out
the light transition.
1.3. DMX Mode
•This mode shall be active when the Mode Selector switch is set to DMX. Or when
the UIM LIGHT CONTROL menu “DMX” option has been selected.
•The software shall allow only the DMX input to adjust the LED functions while in
DMX Mode.
SB 220 Rev-A
9
•All non-LED menu items on the UIM shall be working in DMX Mode with the exception of POWER
ON SETTING at power on.
• The back panel Douse Switch and the UIM Douse Button shall function in DMX Mode.
• This mode shall not have any built-in fade when changing brightness.
1.4. UIM Mode
•This mode shall be active when the Mode Selector switch is set to UIM. Or when the UIM LIGHT
CONTROL menu “UIM” option has been selected.
• The software shall allow only the UIM input to adjust the LED functions while in UIM Mode.
• The Douse Switch and the Douse Button shall function in UIM Mode.
• This mode shall have a built-in 250 millisecond fade when changing brightness to help smooth out
the light transition.
1.5. Proprietary User Interface Module Requirements
•All functions in this section shall be available for use when the Mode Selector switch is set to UIM
mode. Or when the UIM LIGHT CONTROL menu “UIM” option has been selected.
•The software shall display a menu of parameters on the UIM controller. The parameters
listed below shall be displayed in the order shown from top to bottom when the down key is
pressed and shall default to UIM BRIGHTNESS. When the up key is pressed the order will
proceed from LIGHT CONTROL to the bottom of the list, then upwards.
• UIM BRIGHTNESS
• UIM COLOR (Jab Variable model)
• UIM FADE
• UIM EFFECT SELECT
• UIM EFFECT FREQUENCY
• DMX BASE ADDRESS
• DMX CHANNEL MODE
• MODEL NAME / SOFTWARE VERSION / RECALIBRATION PT
• POWER ON SETTING
• SAVE CUSTOM
• RECALL SETTI NG
• LIGHT CONTROL (only if mode switch is absent)
• Under each parameter, the software shall present settings pertaining to the parameter for the user to
select. The settings shall be:
• BRIGHTNESS parameter:
• Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall
scroll by five.
•Each setting value shall represent a brightness level where 0 percent is off and 100
percent is the maximum brightness of the light.
•The change from one brightness value setting to another value shall be as smooth as
possible. The built in smoothing delay shall be 250ms. If the BRIGHTNESS slider on a
DMX board is taken from a positive value all the way to 0, the software shall not
implement any delay unless FADE is non-zero and turn the light off immediately.
•At power on, the factory default value of UIM BRIGHTNESS shall be set at 100%. If a
power on profile is selected that brightness setting will be used. If there is no power on
profile, the brightness will be the ‘last used’ level.
• COLOR TEMP parameter (applies only to Jab Variable Light model):
• Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall
scroll by five.
•Each setting value shall represent a light color temperature level
where 0 percent is completely cool and 100 percent is the maximum
warm setting of the light.
SB 220 Rev-A
10
•At power on, the factory default value of UIM COLOR TEMP shall default to 50 percent.
If a power on profile is selected that associated br ig htn es s level wi ll be used, else the
‘last used’ brightness level will be used.
• FADE parameter:
• Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall
scroll by five.
•Each setting value shall represent a delay in the increase or decrease of the
BRIGHTNESS parameter.
•0 shall indicate that the BRIGHTNESS parameter change is to occur immediately and
100 percent shall introduce a three second delay in changing the current parameter
value to the requested value.
•At power on, the factory default value of UIM FADE shall default to 0 percent. If there is
a power on profile, its associated FADE level shall be used, else the ‘last used’ value will
be used.
• EFFECT SELECT parameter:
• The software shall present individually thirteen choices for the EFFECT SELECT
parameter:
• NONE (OFF) – Turn off any current effect
• STROBE,
• LIGHTNING1 SGL,
• LIGHTNING1 RPT,
• LIGHTNING2 SGL,
• LIGHTNING2 RPT,
• LIGHTNING3 SGL,
• LIGHTNING3 RPT,
• LIGHTNING4 SGL,
• LIGHTNING4 RPT,
• LIGHTNING5 SGL,
• LIGHTNING5 RPT,
• LIGHTNING CYCL
• The choice shall change by one each time a right or left arrow button is pressed.
• STROBE shall make the LEDs emit pulses of light at a 30 percent on/70 percent off duty
cycle and that are of a user designated frequency and brightness. These parameters
are EFFECT FREQUENCY and BRIGHTNESS.
•LIGHTNINGx SGL shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. SGL indicates that this
sequence shall be shown only once per user request. The length and brightness
components of lightning shall be defined in the software. There shall be five different
sequences of lightning defined and designated by a number where the x is located.
•LIGHTNINGx RPT shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. RPT indicates that this
sequence shall be shown repeatedly, with each sequence separated by a two second
off interval. The length and brightness components of lightning shall be defined in the
software. The same five single sequences defined above shall be used for the repeat
lightning.
•LIGHTNING CYCL shall show each sequence in order with each sequence separated
by a two second off interval. At the end of the fifth sequence, the process shall be
repeated.
•If a LIGHTNING effect has been started, it shall be completed even if the user disables
effects during the sequence.
•At power on, the factory default UIM EFFECT SELECT shall default to
NONE(OFF). If there is a power on profile the effect associated with
that profile will be used, else the ‘last used’ value will be used.
•EFFECT FREQUENCY parameter:
SB 220 Rev-A
11
•Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall
scroll by five.
•The power on default value of the UIM EFFECT FREQUENCY parameter shall be 75
percent. If a POWER ON SETTING has been selected, the EFFECT FREQUENCY shall
be the value specified in that setting. If the POWER ON SETTING is turned OFF, the
software shall use the ‘last used’ value’.
•Each setting value shall represent how quickly the lightning and strobe effects operate.
Higher numbers represent a slower effect.
• RECALL SETTING parameter:
• The software shall present individually fifteen choices to the user: PRESET1, PRESET2,
PRESET3, and CUSTOM1 through CUSTOM12 changing the choice each time a right
or left arrow button is pressed. The CUSTOM settings are described below.
•The PRESET settings shall be hard coded into the software and not changeable by the
user.
•When the user presses the select (green check) button, the software shall set the
BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY, DMX Channel, DMX Channel
Mode, and COLOR TEMP (if the light is a Jab Variable model) parameters with the
saved settings from a CUSTOM or a PRESET, given the profile the user has chosen.
•At power on, the RECALL SETTING that is displayed (but not selected) shall default to
PRESET1 if there is no power on profile.
•For all 3 Presets the FADE and EFFECT FREQUENCY shall be zero, and the effect
shall be NONE. Also for all presets the DMX base address shall be 1 and the DMX
Channel Mode shall be 6.
•There shall be three factory presets for the Jab Variable light. For each, the
BRIGHTNESS shall be 100%. Preset one shall set COLOR TEMP at 100%, Preset two
shall set the COLOR TEMP at 45% and Preset three shall set the COLOR TEMP at
10%.
•For the Jab Tungsten and Jab Daylight models the Color temp will always be 0%. Preset
1 will have 100% brightness, Preset 2 will have 45% brightnes s , and Pres et 3 will have
25% brightness.
• For all presets the DMX channel will be 1 and the Channel Mode will be 6.
• SAVE CUSTOM parameter:
• The software shall present individually twelve choices to the user: CUSTOM1 through
CUSTOM12 changing the choice each time the right or left arrow button is pressed.
•When the custom setting is selected (green check button) by the user, the software shall
save the BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY, DMX Channel, DMX
Channel Mode, and COLOR TEMP (if the light is a Jab Variable model) to non-volatile
memory.
• POWER ON SETTING parameter:
• The software shall individually present sixteen choices to the user: PRESET1,
PRESET2, PRESET3, CUSTOM1 through CUSTOM12, and OFF changing the choice
each time the right or left arrow button is pressed.
•When the setting is selected by the user, the software shall save this choice to non-
volatile memory.
•When the light is powered on, the software shall check to see if there is a startup profile
selected and set the BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY and
COLOR TEMP (if the light is a Jab Variable model) parameters with the saved settings
from the profile.
•If no power on default is selected when the light is powered up in UIM control mode the
firmware shall restore BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY and
COLOR TEMP (if the light is a Jab Variable model) settings that were
saved from the last time the light was used These settings shall be
automatically saved every two seconds if any have changed since the
last check.
SB 220 Rev-A
12
• At power on, POWER ON SETTING shall default to OFF if there is no power on profile.
• MODEL NAME parameter:
• Each model shall have its name displayed on the UIM MODEL NAME screen.
• The name shall be one of the following: JAB DAYLIGHT, JAB TUNGSTEN or JAB
VARIABLE, depending on which model is being built.
• RECALIBRATION PT parameter:
• The software shall start at 25000 hours and count down to zero and then count
negatively if necessary to let the user know it is time to have the LED’s replaced. The
time shall count down based on hours of continuous use at a particular brightness
setting.
• SOFTWARE VERSION parameter:
• The software shall maintain and display the software version.
• It shall be in the form: MajorVersion.MinorVersion.Build
• DMX BASE ADDRESS parameter:
• This parameter shall range between 1 and 512. It shall represent the DMX address on
the network that is used to address the light.
• DMX CHANNEL MODE
• There shall be three modes of operation when the light is under DMX control. These
modes are called: 2 CHANNEL, 3 CHANNEL, and 6 CHANNEL mode. In all modes the
first slider controls brightness. In 2 channel mode the second slider controls color
temperature for the Jab Variable model, and has no effect on the other two models. The
third slider controls fade in 3 and 6 channel modes. In 6 channel mode slider 4 controls
effect selection, 5 controls effect frequency, and slider 6 controls effect activation.
• The factory default for the DMX CHANNEL MODE shall be 6 CHANNELS mode.
• LIGHT CONTROL (Only applies to Jab models)
• There shall be two control modes of operation when the Mode Select switch is absent.
These modes are called: UIM and DMX. In UIM mode the UIM controls all light
functions. In DMX mode the DMX interface controls all light functions.
• The factory default for the LIGHT CONTROL shall be UIM.
• The software shall implement medium, medium fast and fast scroll where noted. If the Right or Left
Arrow button is held down for one half second, the values shall be medium scrolled on the display. If the
Arrow button is held down for two seconds the values shall be medium fast scrolled on the display. If the
Arrow button is held down for six seconds the values shall be fast scrolled by five on the display.
•The software shall make sure that the LED’s are powered by the slave PWM processor based on default
settings and/or any saved profile described under POWER ON SETTING before detecting the presence
of a UIM (User Interface Module).
•If a UIM cannot be detected at light startup, the software shall transmit the AADYN TECHNOLOGY
splash screen and check again next time through the main loop. If a UIM is attached after startup, the
software shall display the BRIGHTNESS screen after a five (5) second delay with the splash screen
being shown.
•If the UIM is removed after startup, the software shall maintain the current settings. If the UIM is
reattached later, the splash screen shall show again and any value in the buffer shall be processed.
The software shall retain the menu state after the UIM is unplugged and, if the UIM is reattached, the
splash screen shall show again until any button is pressed. If a benign button is pressed, then the
previous menu shall be displayed; otherwise, the button shall be acted upon and the display shall be
updated appropriatel y.
•The backlight of the UIM shall be tuned off if the user does not press any button for a
period of two minutes. The next subsequent button press shall only turn the backlight
on with no additional action being taken. This includes the UIM douse button.
SB 220 Rev-A
13
1.6. Douse Switch/Douse Button
•The software shall monitor an I/O pin to determine if a momentary switch connected to the light has
been pressed and shall turn off the light for the duration of the switch press.
•Upon release, the software shall allow the light to return to its currently set brightness level if the
Cancel button on the UIM is not pressed.
•The software shall separately detect and process a press and release of the red Cancel (X) button
from the UIM. On Cancel button press, the software shall turn off the LED’s immediately. On
Cancel button release, the software shall turn on the LED’s immediately if the Douse switch is not
being pressed.
1.7. DMX Controller Interface Requirements
•The software shall accept input from the DMX512 controller that represents user requested values
for BRIGHTNESS, COLOR TEMP (if light model is a Jab Variable), FADE, EFFECT, EFFECT
FREQUENCY and EFFECT ACTIVATION.
This light is intended for indoor or outdoor use. When not in use, the light should be stored in a
generally dry and dust free area. General maintenance and care consists of making sure that the light
always has good ventilation and that nothing is obstructing free air flow through and around the light. Do
not use chemicals to clean light. Any cleaning of the light, especially the LED optics should be with a
damp, not wet, soft cloth that is non-abrasive.
Limited Warranty
AADYN TECHNOLOGY, LLC
LIMITED WARRANTY
AAdyn Technology, LLC (“AAdynTech”) products are covered by a limited warranty against
manufacturing defects for two (2) years from the date of purchase by the original purchaser. AAdynTech’s
liability is limited, a t AAdynTech’s option , to repair or r eplacement of the product with the s ame or an equiv alent
product and does not include i nstallatio n costs, r emoval cos ts, or tra nsportatio n costs. AA dynTech res erves the
right to determine whether the AAd ynTech product is defective. D amage due to norm al wear and tear, incorrec t
installation, misuse, abuse, accident, or any cause other than a manufacturing defect is not covered by the
warranty. AAdynTech d isclaim s an y liability for damage to pr oducts, a dapters, ot her prop erty, or per sona l injur y
resulting in whole or in part, from im proper installation or use of its prod ucts. Components not manufacture d by
AAdynTech are subject to t he warranty or guarante e set forth by the manuf acturer thereof, and then on ly to the
extent AAdynTech is able to enforce the warranty or guarantee.
In order to mak e a war ranty c laim , you m us t notif y AAd ynTech in wr iting within s ixt y (60) da ys af ter your
discovery of the defec t, obtain from AAdynTech an RMA, t hen provide proof of purchase, such as the invoice,
and promptly return the product to AAdynTech or its authorized service provider, freight prepaid.
THE FOREGOIN G WARRANTY PROVISION S ARE EXCLUSIVE AND ARE G IVEN AND ACCEPTED
IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION ANY WARRANTY AGAINST INFRINGEMENT AND ANY IMPLIED WARRANT IES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IN NO EVENT SHALL AADYNTECH BE LIABLE FOR INCIDENTAL, COMPENSATORY,
CONSEQUENTIAL, DIRECT, SPECIAL OR OTHER DAMAGES. AADYNTECH’S AGGREGATE LIABILITY
WITH RESPECT TO A DEFECTIVE PRODUCT SHALL IN ANY EVENT BE LIMITED TO THE REPAIR OR
REPLACEMENT O F T H AT DEFE CT IVE PRODUCT O R, AT AADYNTECH ’S OPTION, TH E REIMBURSEME NT
OF THE PURCHASE PRICE THEREFOR.
This warranty is effec tive for purchases of AAdynTech’s pr oduct on or after the eff ective date set forth
below. AAdynTech reserve s the right to modify this warranty from tim e to tim e. Any modif ic ation of this war ranty
shall be effective for all orders placed with AAdynTech on or after the effective date of such revised warranty.
Effective Date: November 11, 2014
All prices and specifications are subject to change without notice.